Pulmonary Embolism in Pneumonia: Still a Diagnostic Challenge? Results of a Case-Control Study in 100 Patients

This study evaluated the diagnostic value of D-dimer, CRP, and leucocytes count to detect an underlying pulmonary embolism (PE) in patients with pneumonia. A predictive model of an underlying PE, based on laboratory markers and clinical symptoms, was our ultimate objective. Overall 100 patients unde...

Descripción completa

Detalles Bibliográficos
Autores principales: Paparoupa, Maria, Spineli, Loukia, Framke, Theodor, Ho, Huy, Schuppert, Frank, Gillissen, Adrian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4897677/
https://www.ncbi.nlm.nih.gov/pubmed/27313336
http://dx.doi.org/10.1155/2016/8682506
_version_ 1782436212505575424
author Paparoupa, Maria
Spineli, Loukia
Framke, Theodor
Ho, Huy
Schuppert, Frank
Gillissen, Adrian
author_facet Paparoupa, Maria
Spineli, Loukia
Framke, Theodor
Ho, Huy
Schuppert, Frank
Gillissen, Adrian
author_sort Paparoupa, Maria
collection PubMed
description This study evaluated the diagnostic value of D-dimer, CRP, and leucocytes count to detect an underlying pulmonary embolism (PE) in patients with pneumonia. A predictive model of an underlying PE, based on laboratory markers and clinical symptoms, was our ultimate objective. Overall 100 patients underwent a computed tomography angiography (CTA) of the lung: 54 with coexistence of PE and pneumonia (cases) and 46 with pneumonia without PE (controls). Cases and controls were matched 1 : 1. Symptoms and paraclinical findings were registered on admission. Receiver operating characteristic (ROC) curves, search for an optimal threshold, and conditional logistic regression analysis were conducted. D-dimer has a moderate ability to detect PE in pneumonia. Sensitivity of D-dimer was estimated at 97.78% and specificity at 11.11%. No optimal cut-point has acceptable diagnostic ability. After excluding patients with sepsis, sensitivity was reduced to 96.97%, whereas specificity increased to 16.13%. Consolidation in chest X-ray and positive D-dimer predict better an underlying PE as D-dimer itself. Thus, discriminatory power of the prediction model (AUC of 0.740) is not much greater than D-dimer (AUC of 0.703). No threshold that could increase the diagnostic value of D-dimer or a prediction model which is significantly better than D-dimer itself was identified.
format Online
Article
Text
id pubmed-4897677
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-48976772016-06-16 Pulmonary Embolism in Pneumonia: Still a Diagnostic Challenge? Results of a Case-Control Study in 100 Patients Paparoupa, Maria Spineli, Loukia Framke, Theodor Ho, Huy Schuppert, Frank Gillissen, Adrian Dis Markers Research Article This study evaluated the diagnostic value of D-dimer, CRP, and leucocytes count to detect an underlying pulmonary embolism (PE) in patients with pneumonia. A predictive model of an underlying PE, based on laboratory markers and clinical symptoms, was our ultimate objective. Overall 100 patients underwent a computed tomography angiography (CTA) of the lung: 54 with coexistence of PE and pneumonia (cases) and 46 with pneumonia without PE (controls). Cases and controls were matched 1 : 1. Symptoms and paraclinical findings were registered on admission. Receiver operating characteristic (ROC) curves, search for an optimal threshold, and conditional logistic regression analysis were conducted. D-dimer has a moderate ability to detect PE in pneumonia. Sensitivity of D-dimer was estimated at 97.78% and specificity at 11.11%. No optimal cut-point has acceptable diagnostic ability. After excluding patients with sepsis, sensitivity was reduced to 96.97%, whereas specificity increased to 16.13%. Consolidation in chest X-ray and positive D-dimer predict better an underlying PE as D-dimer itself. Thus, discriminatory power of the prediction model (AUC of 0.740) is not much greater than D-dimer (AUC of 0.703). No threshold that could increase the diagnostic value of D-dimer or a prediction model which is significantly better than D-dimer itself was identified. Hindawi Publishing Corporation 2016 2016-05-25 /pmc/articles/PMC4897677/ /pubmed/27313336 http://dx.doi.org/10.1155/2016/8682506 Text en Copyright © 2016 Maria Paparoupa et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Paparoupa, Maria
Spineli, Loukia
Framke, Theodor
Ho, Huy
Schuppert, Frank
Gillissen, Adrian
Pulmonary Embolism in Pneumonia: Still a Diagnostic Challenge? Results of a Case-Control Study in 100 Patients
title Pulmonary Embolism in Pneumonia: Still a Diagnostic Challenge? Results of a Case-Control Study in 100 Patients
title_full Pulmonary Embolism in Pneumonia: Still a Diagnostic Challenge? Results of a Case-Control Study in 100 Patients
title_fullStr Pulmonary Embolism in Pneumonia: Still a Diagnostic Challenge? Results of a Case-Control Study in 100 Patients
title_full_unstemmed Pulmonary Embolism in Pneumonia: Still a Diagnostic Challenge? Results of a Case-Control Study in 100 Patients
title_short Pulmonary Embolism in Pneumonia: Still a Diagnostic Challenge? Results of a Case-Control Study in 100 Patients
title_sort pulmonary embolism in pneumonia: still a diagnostic challenge? results of a case-control study in 100 patients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4897677/
https://www.ncbi.nlm.nih.gov/pubmed/27313336
http://dx.doi.org/10.1155/2016/8682506
work_keys_str_mv AT paparoupamaria pulmonaryembolisminpneumoniastilladiagnosticchallengeresultsofacasecontrolstudyin100patients
AT spineliloukia pulmonaryembolisminpneumoniastilladiagnosticchallengeresultsofacasecontrolstudyin100patients
AT framketheodor pulmonaryembolisminpneumoniastilladiagnosticchallengeresultsofacasecontrolstudyin100patients
AT hohuy pulmonaryembolisminpneumoniastilladiagnosticchallengeresultsofacasecontrolstudyin100patients
AT schuppertfrank pulmonaryembolisminpneumoniastilladiagnosticchallengeresultsofacasecontrolstudyin100patients
AT gillissenadrian pulmonaryembolisminpneumoniastilladiagnosticchallengeresultsofacasecontrolstudyin100patients