Cargando…
Pulmonary Embolism in Pneumonia: Still a Diagnostic Challenge? Results of a Case-Control Study in 100 Patients
This study evaluated the diagnostic value of D-dimer, CRP, and leucocytes count to detect an underlying pulmonary embolism (PE) in patients with pneumonia. A predictive model of an underlying PE, based on laboratory markers and clinical symptoms, was our ultimate objective. Overall 100 patients unde...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4897677/ https://www.ncbi.nlm.nih.gov/pubmed/27313336 http://dx.doi.org/10.1155/2016/8682506 |
_version_ | 1782436212505575424 |
---|---|
author | Paparoupa, Maria Spineli, Loukia Framke, Theodor Ho, Huy Schuppert, Frank Gillissen, Adrian |
author_facet | Paparoupa, Maria Spineli, Loukia Framke, Theodor Ho, Huy Schuppert, Frank Gillissen, Adrian |
author_sort | Paparoupa, Maria |
collection | PubMed |
description | This study evaluated the diagnostic value of D-dimer, CRP, and leucocytes count to detect an underlying pulmonary embolism (PE) in patients with pneumonia. A predictive model of an underlying PE, based on laboratory markers and clinical symptoms, was our ultimate objective. Overall 100 patients underwent a computed tomography angiography (CTA) of the lung: 54 with coexistence of PE and pneumonia (cases) and 46 with pneumonia without PE (controls). Cases and controls were matched 1 : 1. Symptoms and paraclinical findings were registered on admission. Receiver operating characteristic (ROC) curves, search for an optimal threshold, and conditional logistic regression analysis were conducted. D-dimer has a moderate ability to detect PE in pneumonia. Sensitivity of D-dimer was estimated at 97.78% and specificity at 11.11%. No optimal cut-point has acceptable diagnostic ability. After excluding patients with sepsis, sensitivity was reduced to 96.97%, whereas specificity increased to 16.13%. Consolidation in chest X-ray and positive D-dimer predict better an underlying PE as D-dimer itself. Thus, discriminatory power of the prediction model (AUC of 0.740) is not much greater than D-dimer (AUC of 0.703). No threshold that could increase the diagnostic value of D-dimer or a prediction model which is significantly better than D-dimer itself was identified. |
format | Online Article Text |
id | pubmed-4897677 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-48976772016-06-16 Pulmonary Embolism in Pneumonia: Still a Diagnostic Challenge? Results of a Case-Control Study in 100 Patients Paparoupa, Maria Spineli, Loukia Framke, Theodor Ho, Huy Schuppert, Frank Gillissen, Adrian Dis Markers Research Article This study evaluated the diagnostic value of D-dimer, CRP, and leucocytes count to detect an underlying pulmonary embolism (PE) in patients with pneumonia. A predictive model of an underlying PE, based on laboratory markers and clinical symptoms, was our ultimate objective. Overall 100 patients underwent a computed tomography angiography (CTA) of the lung: 54 with coexistence of PE and pneumonia (cases) and 46 with pneumonia without PE (controls). Cases and controls were matched 1 : 1. Symptoms and paraclinical findings were registered on admission. Receiver operating characteristic (ROC) curves, search for an optimal threshold, and conditional logistic regression analysis were conducted. D-dimer has a moderate ability to detect PE in pneumonia. Sensitivity of D-dimer was estimated at 97.78% and specificity at 11.11%. No optimal cut-point has acceptable diagnostic ability. After excluding patients with sepsis, sensitivity was reduced to 96.97%, whereas specificity increased to 16.13%. Consolidation in chest X-ray and positive D-dimer predict better an underlying PE as D-dimer itself. Thus, discriminatory power of the prediction model (AUC of 0.740) is not much greater than D-dimer (AUC of 0.703). No threshold that could increase the diagnostic value of D-dimer or a prediction model which is significantly better than D-dimer itself was identified. Hindawi Publishing Corporation 2016 2016-05-25 /pmc/articles/PMC4897677/ /pubmed/27313336 http://dx.doi.org/10.1155/2016/8682506 Text en Copyright © 2016 Maria Paparoupa et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Paparoupa, Maria Spineli, Loukia Framke, Theodor Ho, Huy Schuppert, Frank Gillissen, Adrian Pulmonary Embolism in Pneumonia: Still a Diagnostic Challenge? Results of a Case-Control Study in 100 Patients |
title | Pulmonary Embolism in Pneumonia: Still a Diagnostic Challenge? Results of a Case-Control Study in 100 Patients |
title_full | Pulmonary Embolism in Pneumonia: Still a Diagnostic Challenge? Results of a Case-Control Study in 100 Patients |
title_fullStr | Pulmonary Embolism in Pneumonia: Still a Diagnostic Challenge? Results of a Case-Control Study in 100 Patients |
title_full_unstemmed | Pulmonary Embolism in Pneumonia: Still a Diagnostic Challenge? Results of a Case-Control Study in 100 Patients |
title_short | Pulmonary Embolism in Pneumonia: Still a Diagnostic Challenge? Results of a Case-Control Study in 100 Patients |
title_sort | pulmonary embolism in pneumonia: still a diagnostic challenge? results of a case-control study in 100 patients |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4897677/ https://www.ncbi.nlm.nih.gov/pubmed/27313336 http://dx.doi.org/10.1155/2016/8682506 |
work_keys_str_mv | AT paparoupamaria pulmonaryembolisminpneumoniastilladiagnosticchallengeresultsofacasecontrolstudyin100patients AT spineliloukia pulmonaryembolisminpneumoniastilladiagnosticchallengeresultsofacasecontrolstudyin100patients AT framketheodor pulmonaryembolisminpneumoniastilladiagnosticchallengeresultsofacasecontrolstudyin100patients AT hohuy pulmonaryembolisminpneumoniastilladiagnosticchallengeresultsofacasecontrolstudyin100patients AT schuppertfrank pulmonaryembolisminpneumoniastilladiagnosticchallengeresultsofacasecontrolstudyin100patients AT gillissenadrian pulmonaryembolisminpneumoniastilladiagnosticchallengeresultsofacasecontrolstudyin100patients |