Cargando…
Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens
PURPOSE: The purpose of this study is to compare the optical characteristics of the novel PanOptix presbyopia-correcting trifocal intraocular lens (IOL) and the multifocal ReSTOR +3.0 D IOL, through in vitro bench investigations. METHODS: The optical characteristics of AcrySof(®) IQ PanOptix™ (PanOp...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4898421/ https://www.ncbi.nlm.nih.gov/pubmed/27330273 http://dx.doi.org/10.2147/OPTH.S106646 |
_version_ | 1782436353943797760 |
---|---|
author | Lee, Shinwook Choi, Myoung Xu, Zaiwei Zhao, Zeyu Alexander, Elsinore Liu, Yueai |
author_facet | Lee, Shinwook Choi, Myoung Xu, Zaiwei Zhao, Zeyu Alexander, Elsinore Liu, Yueai |
author_sort | Lee, Shinwook |
collection | PubMed |
description | PURPOSE: The purpose of this study is to compare the optical characteristics of the novel PanOptix presbyopia-correcting trifocal intraocular lens (IOL) and the multifocal ReSTOR +3.0 D IOL, through in vitro bench investigations. METHODS: The optical characteristics of AcrySof(®) IQ PanOptix™ (PanOptix) and AcrySof(®) IQ ReSTOR +3.0 D (ReSTOR +3.0 D) IOLs were evaluated by through-focus Badal images, simulated headlight images, and modulation transfer function (MTF) measurements which determine resolution, photic phenomena, and image quality. Through-focus Badal images of an Early Treatment of Diabetic Retinopathy Study chart were recorded at both photopic and mesopic pupil sizes. Simulated headlight images were taken on an MTF bench with a 50-μm pinhole target and a 5.0 mm pupil at the distance focus of the IOL. MTF curves were measured with a 3.0 mm pupil, and spatial frequencies equivalent to 20/40 and 20/20 visual acuities were recorded to illustrate the through-focus MTF curves. Far-, intermediate-, and near-focus MTF values were obtained. RESULTS: Bench Badal image testing and MTF measurements showed that PanOptix has a near focus at a distance of 42 cm and an additional intermediate focus at a distance of about 60 cm. The near focus for ReSTOR +3.0 D is at 45 cm. PanOptix and ReSTOR +3.0 D have comparable photopic distances and near MTF values. Additionally, PanOptix provided a substantial continuous range of vision from distance to intermediate and to near compared with ReSTOR +3.0 D. The halo propensity for PanOptix was slightly higher than that for ReSTOR +3.0 D. CONCLUSION: Laboratory-based in vitro simulations showed that PanOptix trifocal IOL has comparable resolution and image quality performance in distance and near foci compared with ReSTOR +3.0 D IOL. PanOptix showed better resolution and image quality performance at the intermediate focus than ReSTOR +3.0 D IOL. |
format | Online Article Text |
id | pubmed-4898421 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-48984212016-06-21 Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens Lee, Shinwook Choi, Myoung Xu, Zaiwei Zhao, Zeyu Alexander, Elsinore Liu, Yueai Clin Ophthalmol Original Research PURPOSE: The purpose of this study is to compare the optical characteristics of the novel PanOptix presbyopia-correcting trifocal intraocular lens (IOL) and the multifocal ReSTOR +3.0 D IOL, through in vitro bench investigations. METHODS: The optical characteristics of AcrySof(®) IQ PanOptix™ (PanOptix) and AcrySof(®) IQ ReSTOR +3.0 D (ReSTOR +3.0 D) IOLs were evaluated by through-focus Badal images, simulated headlight images, and modulation transfer function (MTF) measurements which determine resolution, photic phenomena, and image quality. Through-focus Badal images of an Early Treatment of Diabetic Retinopathy Study chart were recorded at both photopic and mesopic pupil sizes. Simulated headlight images were taken on an MTF bench with a 50-μm pinhole target and a 5.0 mm pupil at the distance focus of the IOL. MTF curves were measured with a 3.0 mm pupil, and spatial frequencies equivalent to 20/40 and 20/20 visual acuities were recorded to illustrate the through-focus MTF curves. Far-, intermediate-, and near-focus MTF values were obtained. RESULTS: Bench Badal image testing and MTF measurements showed that PanOptix has a near focus at a distance of 42 cm and an additional intermediate focus at a distance of about 60 cm. The near focus for ReSTOR +3.0 D is at 45 cm. PanOptix and ReSTOR +3.0 D have comparable photopic distances and near MTF values. Additionally, PanOptix provided a substantial continuous range of vision from distance to intermediate and to near compared with ReSTOR +3.0 D. The halo propensity for PanOptix was slightly higher than that for ReSTOR +3.0 D. CONCLUSION: Laboratory-based in vitro simulations showed that PanOptix trifocal IOL has comparable resolution and image quality performance in distance and near foci compared with ReSTOR +3.0 D IOL. PanOptix showed better resolution and image quality performance at the intermediate focus than ReSTOR +3.0 D IOL. Dove Medical Press 2016-06-02 /pmc/articles/PMC4898421/ /pubmed/27330273 http://dx.doi.org/10.2147/OPTH.S106646 Text en © 2016 Lee et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Lee, Shinwook Choi, Myoung Xu, Zaiwei Zhao, Zeyu Alexander, Elsinore Liu, Yueai Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens |
title | Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens |
title_full | Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens |
title_fullStr | Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens |
title_full_unstemmed | Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens |
title_short | Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens |
title_sort | optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4898421/ https://www.ncbi.nlm.nih.gov/pubmed/27330273 http://dx.doi.org/10.2147/OPTH.S106646 |
work_keys_str_mv | AT leeshinwook opticalbenchperformanceofanoveltrifocalintraocularlenscomparedwithamultifocalintraocularlens AT choimyoung opticalbenchperformanceofanoveltrifocalintraocularlenscomparedwithamultifocalintraocularlens AT xuzaiwei opticalbenchperformanceofanoveltrifocalintraocularlenscomparedwithamultifocalintraocularlens AT zhaozeyu opticalbenchperformanceofanoveltrifocalintraocularlenscomparedwithamultifocalintraocularlens AT alexanderelsinore opticalbenchperformanceofanoveltrifocalintraocularlenscomparedwithamultifocalintraocularlens AT liuyueai opticalbenchperformanceofanoveltrifocalintraocularlenscomparedwithamultifocalintraocularlens |