Loading of osseointegrated implants for bone conduction hearing at 3 weeks: 3-year stability, survival, and tolerability

The objective of this study was to ascertain the long-term safety of loading osseointegrated implants for bone conduction hearing 3 weeks post-surgery. Thirty consecutive adult patients were implanted with the Baha BI300 (Cochlear Bone Anchored Solutions) in our tertiary referral center. Implants we...

Descripción completa

Detalles Bibliográficos
Autores principales: Nelissen, Rik C., den Besten, Christine A., Faber, Hubert T., Dun, Catharina A. J., Mylanus, Emmanuel A. M., Hol, Myrthe K. S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4899513/
https://www.ncbi.nlm.nih.gov/pubmed/26272679
http://dx.doi.org/10.1007/s00405-015-3746-y
_version_ 1782436474657964032
author Nelissen, Rik C.
den Besten, Christine A.
Faber, Hubert T.
Dun, Catharina A. J.
Mylanus, Emmanuel A. M.
Hol, Myrthe K. S.
author_facet Nelissen, Rik C.
den Besten, Christine A.
Faber, Hubert T.
Dun, Catharina A. J.
Mylanus, Emmanuel A. M.
Hol, Myrthe K. S.
author_sort Nelissen, Rik C.
collection PubMed
description The objective of this study was to ascertain the long-term safety of loading osseointegrated implants for bone conduction hearing 3 weeks post-surgery. Thirty consecutive adult patients were implanted with the Baha BI300 (Cochlear Bone Anchored Solutions) in our tertiary referral center. Implants were loaded with the sound processor 3 weeks post-surgery. Follow-up examinations were performed at 10 days; 3, 4, 6, 8, and 12 weeks; 6 months; and 1, 2, and 3 years after implant surgery. At each follow-up visit, implant stability quotient (ISQ) values were recorded by means of resonance frequency analysis, and soft tissue status was evaluated according to Holgers’ classification. ISQ trends, implant survival, and soft tissue reactions were compared to a population of 52 patients with the same type of implants loaded from 6 weeks post-surgery as part of another study. Subjective benefit was measured by means of the Glasgow Benefit Inventory (GBI). After an initial dip in ISQ at 10 days after implantation, a gradually increasing trend in ISQ was found until 6 months in both populations, after which ISQ values remained above baseline values. Implant survival was 97 % in the study population and 96 % in the comparison population. Clinically relevant soft tissue reactions were found in 0.9 % (study population) and 1.7 % (comparison population) of all visits. Patients reported subjective benefit; the mean GBI score was 22.8. In conclusion, loading these implants at 3 weeks post-surgery is safe based on the current study, as long-term results show high ISQ values and good implant survival and tolerability.
format Online
Article
Text
id pubmed-4899513
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-48995132016-06-27 Loading of osseointegrated implants for bone conduction hearing at 3 weeks: 3-year stability, survival, and tolerability Nelissen, Rik C. den Besten, Christine A. Faber, Hubert T. Dun, Catharina A. J. Mylanus, Emmanuel A. M. Hol, Myrthe K. S. Eur Arch Otorhinolaryngol Otology The objective of this study was to ascertain the long-term safety of loading osseointegrated implants for bone conduction hearing 3 weeks post-surgery. Thirty consecutive adult patients were implanted with the Baha BI300 (Cochlear Bone Anchored Solutions) in our tertiary referral center. Implants were loaded with the sound processor 3 weeks post-surgery. Follow-up examinations were performed at 10 days; 3, 4, 6, 8, and 12 weeks; 6 months; and 1, 2, and 3 years after implant surgery. At each follow-up visit, implant stability quotient (ISQ) values were recorded by means of resonance frequency analysis, and soft tissue status was evaluated according to Holgers’ classification. ISQ trends, implant survival, and soft tissue reactions were compared to a population of 52 patients with the same type of implants loaded from 6 weeks post-surgery as part of another study. Subjective benefit was measured by means of the Glasgow Benefit Inventory (GBI). After an initial dip in ISQ at 10 days after implantation, a gradually increasing trend in ISQ was found until 6 months in both populations, after which ISQ values remained above baseline values. Implant survival was 97 % in the study population and 96 % in the comparison population. Clinically relevant soft tissue reactions were found in 0.9 % (study population) and 1.7 % (comparison population) of all visits. Patients reported subjective benefit; the mean GBI score was 22.8. In conclusion, loading these implants at 3 weeks post-surgery is safe based on the current study, as long-term results show high ISQ values and good implant survival and tolerability. Springer Berlin Heidelberg 2015-08-14 2016 /pmc/articles/PMC4899513/ /pubmed/26272679 http://dx.doi.org/10.1007/s00405-015-3746-y Text en © The Author(s) 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Otology
Nelissen, Rik C.
den Besten, Christine A.
Faber, Hubert T.
Dun, Catharina A. J.
Mylanus, Emmanuel A. M.
Hol, Myrthe K. S.
Loading of osseointegrated implants for bone conduction hearing at 3 weeks: 3-year stability, survival, and tolerability
title Loading of osseointegrated implants for bone conduction hearing at 3 weeks: 3-year stability, survival, and tolerability
title_full Loading of osseointegrated implants for bone conduction hearing at 3 weeks: 3-year stability, survival, and tolerability
title_fullStr Loading of osseointegrated implants for bone conduction hearing at 3 weeks: 3-year stability, survival, and tolerability
title_full_unstemmed Loading of osseointegrated implants for bone conduction hearing at 3 weeks: 3-year stability, survival, and tolerability
title_short Loading of osseointegrated implants for bone conduction hearing at 3 weeks: 3-year stability, survival, and tolerability
title_sort loading of osseointegrated implants for bone conduction hearing at 3 weeks: 3-year stability, survival, and tolerability
topic Otology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4899513/
https://www.ncbi.nlm.nih.gov/pubmed/26272679
http://dx.doi.org/10.1007/s00405-015-3746-y
work_keys_str_mv AT nelissenrikc loadingofosseointegratedimplantsforboneconductionhearingat3weeks3yearstabilitysurvivalandtolerability
AT denbestenchristinea loadingofosseointegratedimplantsforboneconductionhearingat3weeks3yearstabilitysurvivalandtolerability
AT faberhubertt loadingofosseointegratedimplantsforboneconductionhearingat3weeks3yearstabilitysurvivalandtolerability
AT duncatharinaaj loadingofosseointegratedimplantsforboneconductionhearingat3weeks3yearstabilitysurvivalandtolerability
AT mylanusemmanuelam loadingofosseointegratedimplantsforboneconductionhearingat3weeks3yearstabilitysurvivalandtolerability
AT holmyrtheks loadingofosseointegratedimplantsforboneconductionhearingat3weeks3yearstabilitysurvivalandtolerability