Cargando…

Biomechanical Evaluation of Capsulotomy and Capsular Repair in the Hip: Restoring Stability

OBJECTIVES: The use of hip arthroscopy has increased over recent years to treat various forms of hip pathologies including femoroacetabular impingement. While a capsulotomy facilitates adequate visualization and access for diagnostic and interventional purposes, the current literature remains divide...

Descripción completa

Detalles Bibliográficos
Autores principales: Wuerz, Thomas H., Song, Sang Hoon, Grzybowski, Jeffrey S., Greenberg, Mitchell, Espinoza, Alejandro, Nho, Shane Jay
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4901697/
http://dx.doi.org/10.1177/2325967115S00134
_version_ 1782436859359526912
author Wuerz, Thomas H.
Song, Sang Hoon
Grzybowski, Jeffrey S.
Greenberg, Mitchell
Espinoza, Alejandro
Nho, Shane Jay
author_facet Wuerz, Thomas H.
Song, Sang Hoon
Grzybowski, Jeffrey S.
Greenberg, Mitchell
Espinoza, Alejandro
Nho, Shane Jay
author_sort Wuerz, Thomas H.
collection PubMed
description OBJECTIVES: The use of hip arthroscopy has increased over recent years to treat various forms of hip pathologies including femoroacetabular impingement. While a capsulotomy facilitates adequate visualization and access for diagnostic and interventional purposes, the current literature remains divided over the use of routine capsular closure to address the iatrogenic instability that may be induced by an excessive or unclosed capsulotomy. The purpose of this biomechanical study was to determine if hip capsulotomy creates significant alterations in rotational range of motion and stability measures. Additionally, does a capsular repair return these variables to normal? METHODS: Eight fresh-frozen cadaveric hip specimens consisting of the hemipelvis, femur, and overlying soft tissues were used for this study. All specimens were screened by computed tomography (CT) to assess for the absence of significant bony pathology. Each hip was then tested under torsional loads of 6 N·m applied via a pulley system in conjunction with a vertical force exerted by a servohydraulic frame. Conditions tested were as follows: 1) neutral flexion with the capsule intact 2) neutral flexion with a 4 cm inter-portal capsulotomy 3) neutral flexion with a 6 cm inter-portal capsulotomy 4) neutral flexion with capsulotomy repair. Soft tissue was retained during all interventions. Range of motion (from external to internal rotation), hysteresis area, and neutral zones were the outcome measures for stability obtained in each condition. RESULTS: While the data demonstrated a positive and statistically significant correlation between the sizes of the capsulotomy and measures of joint instability (range of motion (ROM), hysteresis area, and neutral zone), no significant differences were seen between the intact and repaired hips with regards to such measures (Table). Larger size capsulotomies were accompanied by significant increases in all three measures of joint instability while the repair effectively restored the capsule to conditions similar to its intact state. CONCLUSION: To the best of the authors’ knowledge, this study is the first to demonstrate the biomechanical consequences of sequentially increasing capsulotomy incisions and their repair on a hip joint that still contains its surrounding soft tissue. The results of this study not only confirm the notion of introducing iatrogenic joint instability with larger sized capsulotomies, but also propose the complete capsular closure as an appropriate solution.
format Online
Article
Text
id pubmed-4901697
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-49016972016-06-10 Biomechanical Evaluation of Capsulotomy and Capsular Repair in the Hip: Restoring Stability Wuerz, Thomas H. Song, Sang Hoon Grzybowski, Jeffrey S. Greenberg, Mitchell Espinoza, Alejandro Nho, Shane Jay Orthop J Sports Med Article OBJECTIVES: The use of hip arthroscopy has increased over recent years to treat various forms of hip pathologies including femoroacetabular impingement. While a capsulotomy facilitates adequate visualization and access for diagnostic and interventional purposes, the current literature remains divided over the use of routine capsular closure to address the iatrogenic instability that may be induced by an excessive or unclosed capsulotomy. The purpose of this biomechanical study was to determine if hip capsulotomy creates significant alterations in rotational range of motion and stability measures. Additionally, does a capsular repair return these variables to normal? METHODS: Eight fresh-frozen cadaveric hip specimens consisting of the hemipelvis, femur, and overlying soft tissues were used for this study. All specimens were screened by computed tomography (CT) to assess for the absence of significant bony pathology. Each hip was then tested under torsional loads of 6 N·m applied via a pulley system in conjunction with a vertical force exerted by a servohydraulic frame. Conditions tested were as follows: 1) neutral flexion with the capsule intact 2) neutral flexion with a 4 cm inter-portal capsulotomy 3) neutral flexion with a 6 cm inter-portal capsulotomy 4) neutral flexion with capsulotomy repair. Soft tissue was retained during all interventions. Range of motion (from external to internal rotation), hysteresis area, and neutral zones were the outcome measures for stability obtained in each condition. RESULTS: While the data demonstrated a positive and statistically significant correlation between the sizes of the capsulotomy and measures of joint instability (range of motion (ROM), hysteresis area, and neutral zone), no significant differences were seen between the intact and repaired hips with regards to such measures (Table). Larger size capsulotomies were accompanied by significant increases in all three measures of joint instability while the repair effectively restored the capsule to conditions similar to its intact state. CONCLUSION: To the best of the authors’ knowledge, this study is the first to demonstrate the biomechanical consequences of sequentially increasing capsulotomy incisions and their repair on a hip joint that still contains its surrounding soft tissue. The results of this study not only confirm the notion of introducing iatrogenic joint instability with larger sized capsulotomies, but also propose the complete capsular closure as an appropriate solution. SAGE Publications 2015-07-17 /pmc/articles/PMC4901697/ http://dx.doi.org/10.1177/2325967115S00134 Text en © The Author(s) 2015 http://creativecommons.org/licenses/by-nc-nd/3.0/ This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For reprints and permission queries, please visit SAGE’s Web site at http://www.sagepub.com/journalsPermissions.nav.
spellingShingle Article
Wuerz, Thomas H.
Song, Sang Hoon
Grzybowski, Jeffrey S.
Greenberg, Mitchell
Espinoza, Alejandro
Nho, Shane Jay
Biomechanical Evaluation of Capsulotomy and Capsular Repair in the Hip: Restoring Stability
title Biomechanical Evaluation of Capsulotomy and Capsular Repair in the Hip: Restoring Stability
title_full Biomechanical Evaluation of Capsulotomy and Capsular Repair in the Hip: Restoring Stability
title_fullStr Biomechanical Evaluation of Capsulotomy and Capsular Repair in the Hip: Restoring Stability
title_full_unstemmed Biomechanical Evaluation of Capsulotomy and Capsular Repair in the Hip: Restoring Stability
title_short Biomechanical Evaluation of Capsulotomy and Capsular Repair in the Hip: Restoring Stability
title_sort biomechanical evaluation of capsulotomy and capsular repair in the hip: restoring stability
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4901697/
http://dx.doi.org/10.1177/2325967115S00134
work_keys_str_mv AT wuerzthomash biomechanicalevaluationofcapsulotomyandcapsularrepairinthehiprestoringstability
AT songsanghoon biomechanicalevaluationofcapsulotomyandcapsularrepairinthehiprestoringstability
AT grzybowskijeffreys biomechanicalevaluationofcapsulotomyandcapsularrepairinthehiprestoringstability
AT greenbergmitchell biomechanicalevaluationofcapsulotomyandcapsularrepairinthehiprestoringstability
AT espinozaalejandro biomechanicalevaluationofcapsulotomyandcapsularrepairinthehiprestoringstability
AT nhoshanejay biomechanicalevaluationofcapsulotomyandcapsularrepairinthehiprestoringstability