Cargando…
Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens
BACKGROUND: This study evaluated the visual function after implantation of a multifocal toric intraocular lenses (IOLs). MATERIALS AND METHODS: This study involved 10 eyes from eight cataract patients with corneal astigmatism of 1.0 diopter (D) or higher who had received phacoemulsification with imp...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4901846/ https://www.ncbi.nlm.nih.gov/pubmed/27221680 http://dx.doi.org/10.4103/0301-4738.182939 |
_version_ | 1782436887184539648 |
---|---|
author | Chen, Xiangfei Zhao, Ming Shi, Yuhua Yang, Liping Lu, Yan Huang, Zhenping |
author_facet | Chen, Xiangfei Zhao, Ming Shi, Yuhua Yang, Liping Lu, Yan Huang, Zhenping |
author_sort | Chen, Xiangfei |
collection | PubMed |
description | BACKGROUND: This study evaluated the visual function after implantation of a multifocal toric intraocular lenses (IOLs). MATERIALS AND METHODS: This study involved 10 eyes from eight cataract patients with corneal astigmatism of 1.0 diopter (D) or higher who had received phacoemulsification with implantation of an AcrySof IQ ReSTOR Toric IOL. Six-month evaluations included visual acuity, spherical equivalent (SE), defocus curve, residual astigmatism, IOL rotation, contrast sensitivity (CS), wavefront aberrations, modulation transfer function (MTF), and patient satisfaction assessments. RESULTS: At 6 months postoperatively, uncorrected distance visual acuity (logarithm of the minimum angle of resolution) was 0.09 ± 0.04, corrected distance visual acuity was 0.02 ± 0.11, and uncorrected near visual acuity was 0.12 ± 0.07. The mean SE was −0.095 ± 0.394 D (±0.50 D in 90%). Refractive astigmatism at the 6-month follow-up visit was significantly reduced to 0.35 ± 0.32 D from 1.50 ± 0.41 D presurgery (P < 0.05). The mean IOL axis rotation was 3.20 ± 1.55°. Postoperative CS levels were high. Postoperative total order aberrations (TOAs), lower-order aberrations (LOAs), higher-order aberrations (HOAs), and spherical aberrations were decreased compared with preoperative values (P < 0.05). At 3 months postoperatively, TOAs, LOAs, and HOAs with a 3 mm pupil diameter as well as TOAs, LOAs, and astigmatism aberrations with a 5 mm pupil diameter were statistically lower than those at 1-month post surgery, but without subsequent significant changes (P > 0.05). There was an increase in MTF results between preoperative and postoperative evaluations at all spatial frequencies. CONCLUSIONS: The diffractive multifocal toric IOL is able to provide a predictable astigmatic correction with apparently outstanding levels of optical quality after implantation. |
format | Online Article Text |
id | pubmed-4901846 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-49018462016-06-16 Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens Chen, Xiangfei Zhao, Ming Shi, Yuhua Yang, Liping Lu, Yan Huang, Zhenping Indian J Ophthalmol Original Article BACKGROUND: This study evaluated the visual function after implantation of a multifocal toric intraocular lenses (IOLs). MATERIALS AND METHODS: This study involved 10 eyes from eight cataract patients with corneal astigmatism of 1.0 diopter (D) or higher who had received phacoemulsification with implantation of an AcrySof IQ ReSTOR Toric IOL. Six-month evaluations included visual acuity, spherical equivalent (SE), defocus curve, residual astigmatism, IOL rotation, contrast sensitivity (CS), wavefront aberrations, modulation transfer function (MTF), and patient satisfaction assessments. RESULTS: At 6 months postoperatively, uncorrected distance visual acuity (logarithm of the minimum angle of resolution) was 0.09 ± 0.04, corrected distance visual acuity was 0.02 ± 0.11, and uncorrected near visual acuity was 0.12 ± 0.07. The mean SE was −0.095 ± 0.394 D (±0.50 D in 90%). Refractive astigmatism at the 6-month follow-up visit was significantly reduced to 0.35 ± 0.32 D from 1.50 ± 0.41 D presurgery (P < 0.05). The mean IOL axis rotation was 3.20 ± 1.55°. Postoperative CS levels were high. Postoperative total order aberrations (TOAs), lower-order aberrations (LOAs), higher-order aberrations (HOAs), and spherical aberrations were decreased compared with preoperative values (P < 0.05). At 3 months postoperatively, TOAs, LOAs, and HOAs with a 3 mm pupil diameter as well as TOAs, LOAs, and astigmatism aberrations with a 5 mm pupil diameter were statistically lower than those at 1-month post surgery, but without subsequent significant changes (P > 0.05). There was an increase in MTF results between preoperative and postoperative evaluations at all spatial frequencies. CONCLUSIONS: The diffractive multifocal toric IOL is able to provide a predictable astigmatic correction with apparently outstanding levels of optical quality after implantation. Medknow Publications & Media Pvt Ltd 2016-04 /pmc/articles/PMC4901846/ /pubmed/27221680 http://dx.doi.org/10.4103/0301-4738.182939 Text en Copyright: © Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution NonCommercial ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Chen, Xiangfei Zhao, Ming Shi, Yuhua Yang, Liping Lu, Yan Huang, Zhenping Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens |
title | Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens |
title_full | Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens |
title_fullStr | Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens |
title_full_unstemmed | Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens |
title_short | Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens |
title_sort | visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4901846/ https://www.ncbi.nlm.nih.gov/pubmed/27221680 http://dx.doi.org/10.4103/0301-4738.182939 |
work_keys_str_mv | AT chenxiangfei visualoutcomesandopticalqualityafterimplantationofadiffractivemultifocaltoricintraocularlens AT zhaoming visualoutcomesandopticalqualityafterimplantationofadiffractivemultifocaltoricintraocularlens AT shiyuhua visualoutcomesandopticalqualityafterimplantationofadiffractivemultifocaltoricintraocularlens AT yangliping visualoutcomesandopticalqualityafterimplantationofadiffractivemultifocaltoricintraocularlens AT luyan visualoutcomesandopticalqualityafterimplantationofadiffractivemultifocaltoricintraocularlens AT huangzhenping visualoutcomesandopticalqualityafterimplantationofadiffractivemultifocaltoricintraocularlens |