Cargando…

Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens

BACKGROUND: This study evaluated the visual function after implantation of a multifocal toric intraocular lenses (IOLs). MATERIALS AND METHODS: This study involved 10 eyes from eight cataract patients with corneal astigmatism of 1.0 diopter (D) or higher who had received phacoemulsification with imp...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Xiangfei, Zhao, Ming, Shi, Yuhua, Yang, Liping, Lu, Yan, Huang, Zhenping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4901846/
https://www.ncbi.nlm.nih.gov/pubmed/27221680
http://dx.doi.org/10.4103/0301-4738.182939
_version_ 1782436887184539648
author Chen, Xiangfei
Zhao, Ming
Shi, Yuhua
Yang, Liping
Lu, Yan
Huang, Zhenping
author_facet Chen, Xiangfei
Zhao, Ming
Shi, Yuhua
Yang, Liping
Lu, Yan
Huang, Zhenping
author_sort Chen, Xiangfei
collection PubMed
description BACKGROUND: This study evaluated the visual function after implantation of a multifocal toric intraocular lenses (IOLs). MATERIALS AND METHODS: This study involved 10 eyes from eight cataract patients with corneal astigmatism of 1.0 diopter (D) or higher who had received phacoemulsification with implantation of an AcrySof IQ ReSTOR Toric IOL. Six-month evaluations included visual acuity, spherical equivalent (SE), defocus curve, residual astigmatism, IOL rotation, contrast sensitivity (CS), wavefront aberrations, modulation transfer function (MTF), and patient satisfaction assessments. RESULTS: At 6 months postoperatively, uncorrected distance visual acuity (logarithm of the minimum angle of resolution) was 0.09 ± 0.04, corrected distance visual acuity was 0.02 ± 0.11, and uncorrected near visual acuity was 0.12 ± 0.07. The mean SE was −0.095 ± 0.394 D (±0.50 D in 90%). Refractive astigmatism at the 6-month follow-up visit was significantly reduced to 0.35 ± 0.32 D from 1.50 ± 0.41 D presurgery (P < 0.05). The mean IOL axis rotation was 3.20 ± 1.55°. Postoperative CS levels were high. Postoperative total order aberrations (TOAs), lower-order aberrations (LOAs), higher-order aberrations (HOAs), and spherical aberrations were decreased compared with preoperative values (P < 0.05). At 3 months postoperatively, TOAs, LOAs, and HOAs with a 3 mm pupil diameter as well as TOAs, LOAs, and astigmatism aberrations with a 5 mm pupil diameter were statistically lower than those at 1-month post surgery, but without subsequent significant changes (P > 0.05). There was an increase in MTF results between preoperative and postoperative evaluations at all spatial frequencies. CONCLUSIONS: The diffractive multifocal toric IOL is able to provide a predictable astigmatic correction with apparently outstanding levels of optical quality after implantation.
format Online
Article
Text
id pubmed-4901846
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-49018462016-06-16 Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens Chen, Xiangfei Zhao, Ming Shi, Yuhua Yang, Liping Lu, Yan Huang, Zhenping Indian J Ophthalmol Original Article BACKGROUND: This study evaluated the visual function after implantation of a multifocal toric intraocular lenses (IOLs). MATERIALS AND METHODS: This study involved 10 eyes from eight cataract patients with corneal astigmatism of 1.0 diopter (D) or higher who had received phacoemulsification with implantation of an AcrySof IQ ReSTOR Toric IOL. Six-month evaluations included visual acuity, spherical equivalent (SE), defocus curve, residual astigmatism, IOL rotation, contrast sensitivity (CS), wavefront aberrations, modulation transfer function (MTF), and patient satisfaction assessments. RESULTS: At 6 months postoperatively, uncorrected distance visual acuity (logarithm of the minimum angle of resolution) was 0.09 ± 0.04, corrected distance visual acuity was 0.02 ± 0.11, and uncorrected near visual acuity was 0.12 ± 0.07. The mean SE was −0.095 ± 0.394 D (±0.50 D in 90%). Refractive astigmatism at the 6-month follow-up visit was significantly reduced to 0.35 ± 0.32 D from 1.50 ± 0.41 D presurgery (P < 0.05). The mean IOL axis rotation was 3.20 ± 1.55°. Postoperative CS levels were high. Postoperative total order aberrations (TOAs), lower-order aberrations (LOAs), higher-order aberrations (HOAs), and spherical aberrations were decreased compared with preoperative values (P < 0.05). At 3 months postoperatively, TOAs, LOAs, and HOAs with a 3 mm pupil diameter as well as TOAs, LOAs, and astigmatism aberrations with a 5 mm pupil diameter were statistically lower than those at 1-month post surgery, but without subsequent significant changes (P > 0.05). There was an increase in MTF results between preoperative and postoperative evaluations at all spatial frequencies. CONCLUSIONS: The diffractive multifocal toric IOL is able to provide a predictable astigmatic correction with apparently outstanding levels of optical quality after implantation. Medknow Publications & Media Pvt Ltd 2016-04 /pmc/articles/PMC4901846/ /pubmed/27221680 http://dx.doi.org/10.4103/0301-4738.182939 Text en Copyright: © Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution NonCommercial ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Chen, Xiangfei
Zhao, Ming
Shi, Yuhua
Yang, Liping
Lu, Yan
Huang, Zhenping
Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens
title Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens
title_full Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens
title_fullStr Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens
title_full_unstemmed Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens
title_short Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens
title_sort visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4901846/
https://www.ncbi.nlm.nih.gov/pubmed/27221680
http://dx.doi.org/10.4103/0301-4738.182939
work_keys_str_mv AT chenxiangfei visualoutcomesandopticalqualityafterimplantationofadiffractivemultifocaltoricintraocularlens
AT zhaoming visualoutcomesandopticalqualityafterimplantationofadiffractivemultifocaltoricintraocularlens
AT shiyuhua visualoutcomesandopticalqualityafterimplantationofadiffractivemultifocaltoricintraocularlens
AT yangliping visualoutcomesandopticalqualityafterimplantationofadiffractivemultifocaltoricintraocularlens
AT luyan visualoutcomesandopticalqualityafterimplantationofadiffractivemultifocaltoricintraocularlens
AT huangzhenping visualoutcomesandopticalqualityafterimplantationofadiffractivemultifocaltoricintraocularlens