Cargando…
Death Due to Intra-aortic Migration of Kirschner Wire From the Clavicle: A Case Report and Review of the Literature
Migration of orthopedic fixation wires into the ascending aorta though a rare occurrence can have devastating consequences. Therefore, prompt recognition, with immediate and cautious retrieval of the implant is paramount in averting these complications. We present a case of a 5-year-old boy with the...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4902362/ https://www.ncbi.nlm.nih.gov/pubmed/27227938 http://dx.doi.org/10.1097/MD.0000000000003741 |
_version_ | 1782436974741684224 |
---|---|
author | Tan, Lei Sun, Da-Hui Yu, Tiecheng Wang, Linxiang Zhu, Dong Li, Yan-Hui |
author_facet | Tan, Lei Sun, Da-Hui Yu, Tiecheng Wang, Linxiang Zhu, Dong Li, Yan-Hui |
author_sort | Tan, Lei |
collection | PubMed |
description | Migration of orthopedic fixation wires into the ascending aorta though a rare occurrence can have devastating consequences. Therefore, prompt recognition, with immediate and cautious retrieval of the implant is paramount in averting these complications. We present a case of a 5-year-old boy with the intra-aortic migration of a K-wire used for the treatment of a right clavicle fracture. He was transferred to us with a history of syncope, chest pain, and shortness of breath 7 days after K-wire placement, which was performed at another hospital. On CT scan, the wire was found to be partially inside the ascending aorta, which was associated with massive hemopericardium and cardiac tamponade. The patient was taken up for emergency surgery for the removal K-wire and for the management of cardiac temponade. However, the patient developed cardiac arrest during the induction of intravenous anesthesia and endotracheal intubation. The K-wire was retrieved from the thorax via thoracotomy. However, the patient died 10 days after the surgery. As the migration of wires and pins during orthopedic surgery can cause potentially fatal complications, these should be used very cautiously, especially for percutaneous treatment of shoulder girdle fractures. The patients with such implants should be followed frequently, both clinically and radiographically. If migration occurs, the patient should be closely monitored for emergent complications and the K-wire should be extracted immediately. |
format | Online Article Text |
id | pubmed-4902362 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-49023622016-06-23 Death Due to Intra-aortic Migration of Kirschner Wire From the Clavicle: A Case Report and Review of the Literature Tan, Lei Sun, Da-Hui Yu, Tiecheng Wang, Linxiang Zhu, Dong Li, Yan-Hui Medicine (Baltimore) 7100 Migration of orthopedic fixation wires into the ascending aorta though a rare occurrence can have devastating consequences. Therefore, prompt recognition, with immediate and cautious retrieval of the implant is paramount in averting these complications. We present a case of a 5-year-old boy with the intra-aortic migration of a K-wire used for the treatment of a right clavicle fracture. He was transferred to us with a history of syncope, chest pain, and shortness of breath 7 days after K-wire placement, which was performed at another hospital. On CT scan, the wire was found to be partially inside the ascending aorta, which was associated with massive hemopericardium and cardiac tamponade. The patient was taken up for emergency surgery for the removal K-wire and for the management of cardiac temponade. However, the patient developed cardiac arrest during the induction of intravenous anesthesia and endotracheal intubation. The K-wire was retrieved from the thorax via thoracotomy. However, the patient died 10 days after the surgery. As the migration of wires and pins during orthopedic surgery can cause potentially fatal complications, these should be used very cautiously, especially for percutaneous treatment of shoulder girdle fractures. The patients with such implants should be followed frequently, both clinically and radiographically. If migration occurs, the patient should be closely monitored for emergent complications and the K-wire should be extracted immediately. Wolters Kluwer Health 2016-05-27 /pmc/articles/PMC4902362/ /pubmed/27227938 http://dx.doi.org/10.1097/MD.0000000000003741 Text en Copyright © 2016 Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0 |
spellingShingle | 7100 Tan, Lei Sun, Da-Hui Yu, Tiecheng Wang, Linxiang Zhu, Dong Li, Yan-Hui Death Due to Intra-aortic Migration of Kirschner Wire From the Clavicle: A Case Report and Review of the Literature |
title | Death Due to Intra-aortic Migration of Kirschner Wire From the Clavicle: A Case Report and Review of the Literature |
title_full | Death Due to Intra-aortic Migration of Kirschner Wire From the Clavicle: A Case Report and Review of the Literature |
title_fullStr | Death Due to Intra-aortic Migration of Kirschner Wire From the Clavicle: A Case Report and Review of the Literature |
title_full_unstemmed | Death Due to Intra-aortic Migration of Kirschner Wire From the Clavicle: A Case Report and Review of the Literature |
title_short | Death Due to Intra-aortic Migration of Kirschner Wire From the Clavicle: A Case Report and Review of the Literature |
title_sort | death due to intra-aortic migration of kirschner wire from the clavicle: a case report and review of the literature |
topic | 7100 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4902362/ https://www.ncbi.nlm.nih.gov/pubmed/27227938 http://dx.doi.org/10.1097/MD.0000000000003741 |
work_keys_str_mv | AT tanlei deathduetointraaorticmigrationofkirschnerwirefromtheclavicleacasereportandreviewoftheliterature AT sundahui deathduetointraaorticmigrationofkirschnerwirefromtheclavicleacasereportandreviewoftheliterature AT yutiecheng deathduetointraaorticmigrationofkirschnerwirefromtheclavicleacasereportandreviewoftheliterature AT wanglinxiang deathduetointraaorticmigrationofkirschnerwirefromtheclavicleacasereportandreviewoftheliterature AT zhudong deathduetointraaorticmigrationofkirschnerwirefromtheclavicleacasereportandreviewoftheliterature AT liyanhui deathduetointraaorticmigrationofkirschnerwirefromtheclavicleacasereportandreviewoftheliterature |