Novel application of chemical shift gradient echo in- and opposed-phase sequences in 3 T MRI for the detection of H-MRS visible lipids and grading of glioma
OBJECTIVES: We evaluated the feasibility of using chemical shift gradient-echo (GE) in- and opposed-phase (IOP) imaging to grade glioma. METHODS: A phantom study was performed to investigate the correlation of (1)H MRS-visible lipids with the signal loss ratio (SLR) obtained using IOP imaging. A cro...
Autores principales: | Ramli, Norlisah, Khairy, Azua Mohd, Seow, Pohchoo, Tan, Li Kuo, Wong, Jeannie Hsiu Ding, Ganesan, Dharmendra, Rahmat, Kartini |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4902846/ https://www.ncbi.nlm.nih.gov/pubmed/26560718 http://dx.doi.org/10.1007/s00330-015-4045-0 |
Ejemplares similares
-
A comparison of multi-echo spin-echo and triple-echo steady-state T2 mapping for in vivo evaluation of articular cartilage
por: Juras, Vladimir, et al.
Publicado: (2015) -
1.5-T MR relaxometry in quantifying splenic and pancreatic iron: retrospective comparison of a commercial 3D-Dixon sequence and an established 2D multi-gradient echo sequence
por: Plaikner, Michaela, et al.
Publicado: (2023) -
Diagnostic value of MRS-quantified brain tissue lactate level in identifying children with mitochondrial disorders
por: Lunsing, Roelineke J., et al.
Publicado: (2016) -
Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
por: An, He, et al.
Publicado: (2019) -
Quantification and visualization of lipid landscape in glioma using in -and opposed-phase imaging
por: Seow, Pohchoo, et al.
Publicado: (2018)