Cargando…
Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III)
Purpose. To investigate the agreement between morphometric optic nerve head parameters assessed with the confocal laser ophthalmoscope HRT III and the stereoscopic fundus camera Kowa nonmyd WX3D retrospectively. Methods. Morphometric optic nerve head parameters of 40 eyes of 40 patients with primary...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4904126/ https://www.ncbi.nlm.nih.gov/pubmed/27313870 http://dx.doi.org/10.1155/2016/4764857 |
_version_ | 1782437101562757120 |
---|---|
author | Mariacher, Siegfried Hipp, Stephanie Wirthky, Robert Blumenstock, Gunnar Bartz-Schmidt, Karl-Ulrich Ziemssen, Focke Schiefer, Ulrich Voykov, Bogomil Januschowski, Kai |
author_facet | Mariacher, Siegfried Hipp, Stephanie Wirthky, Robert Blumenstock, Gunnar Bartz-Schmidt, Karl-Ulrich Ziemssen, Focke Schiefer, Ulrich Voykov, Bogomil Januschowski, Kai |
author_sort | Mariacher, Siegfried |
collection | PubMed |
description | Purpose. To investigate the agreement between morphometric optic nerve head parameters assessed with the confocal laser ophthalmoscope HRT III and the stereoscopic fundus camera Kowa nonmyd WX3D retrospectively. Methods. Morphometric optic nerve head parameters of 40 eyes of 40 patients with primary open angle glaucoma were analyzed regarding their vertical cup-to-disc-ratio (CDR). Vertical CDR, disc area, cup volume, rim volume, and maximum cup depth were assessed with both devices by one examiner. Mean bias and limits of agreement (95% CI) were obtained using scatter plots and Bland-Altman analysis. Results. Overall vertical CDR comparison between HRT III and Kowa nonmyd WX3D measurements showed a mean difference (limits of agreement) of −0.06 (−0.36 to 0.24). For the CDR < 0.5 group (n = 24) mean difference in vertical CDR was −0.14 (−0.34 to 0.06) and for the CDR ≥ 0.5 group (n = 16) 0.06 (−0.21 to 0.34). Conclusion. This study showed a good agreement between Kowa nonmyd WX3D and HRT III with regard to widely used optic nerve head parameters in patients with glaucomatous optic neuropathy. However, data from Kowa nonmyd WX3D exhibited the tendency to measure larger CDR values than HRT III in the group with CDR < 0.5 group and lower CDR values in the group with CDR ≥ 0.5. |
format | Online Article Text |
id | pubmed-4904126 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-49041262016-06-16 Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III) Mariacher, Siegfried Hipp, Stephanie Wirthky, Robert Blumenstock, Gunnar Bartz-Schmidt, Karl-Ulrich Ziemssen, Focke Schiefer, Ulrich Voykov, Bogomil Januschowski, Kai J Ophthalmol Research Article Purpose. To investigate the agreement between morphometric optic nerve head parameters assessed with the confocal laser ophthalmoscope HRT III and the stereoscopic fundus camera Kowa nonmyd WX3D retrospectively. Methods. Morphometric optic nerve head parameters of 40 eyes of 40 patients with primary open angle glaucoma were analyzed regarding their vertical cup-to-disc-ratio (CDR). Vertical CDR, disc area, cup volume, rim volume, and maximum cup depth were assessed with both devices by one examiner. Mean bias and limits of agreement (95% CI) were obtained using scatter plots and Bland-Altman analysis. Results. Overall vertical CDR comparison between HRT III and Kowa nonmyd WX3D measurements showed a mean difference (limits of agreement) of −0.06 (−0.36 to 0.24). For the CDR < 0.5 group (n = 24) mean difference in vertical CDR was −0.14 (−0.34 to 0.06) and for the CDR ≥ 0.5 group (n = 16) 0.06 (−0.21 to 0.34). Conclusion. This study showed a good agreement between Kowa nonmyd WX3D and HRT III with regard to widely used optic nerve head parameters in patients with glaucomatous optic neuropathy. However, data from Kowa nonmyd WX3D exhibited the tendency to measure larger CDR values than HRT III in the group with CDR < 0.5 group and lower CDR values in the group with CDR ≥ 0.5. Hindawi Publishing Corporation 2016 2016-05-30 /pmc/articles/PMC4904126/ /pubmed/27313870 http://dx.doi.org/10.1155/2016/4764857 Text en Copyright © 2016 Siegfried Mariacher et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Mariacher, Siegfried Hipp, Stephanie Wirthky, Robert Blumenstock, Gunnar Bartz-Schmidt, Karl-Ulrich Ziemssen, Focke Schiefer, Ulrich Voykov, Bogomil Januschowski, Kai Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III) |
title | Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III) |
title_full | Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III) |
title_fullStr | Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III) |
title_full_unstemmed | Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III) |
title_short | Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III) |
title_sort | morphometric optic nerve head analysis in glaucoma patients: a comparison between the simultaneous nonmydriatic stereoscopic fundus camera (kowa nonmyd wx3d) and the heidelberg scanning laser ophthalmoscope (hrt iii) |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4904126/ https://www.ncbi.nlm.nih.gov/pubmed/27313870 http://dx.doi.org/10.1155/2016/4764857 |
work_keys_str_mv | AT mariachersiegfried morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii AT hippstephanie morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii AT wirthkyrobert morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii AT blumenstockgunnar morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii AT bartzschmidtkarlulrich morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii AT ziemssenfocke morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii AT schieferulrich morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii AT voykovbogomil morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii AT januschowskikai morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii |