Cargando…

Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III)

Purpose. To investigate the agreement between morphometric optic nerve head parameters assessed with the confocal laser ophthalmoscope HRT III and the stereoscopic fundus camera Kowa nonmyd WX3D retrospectively. Methods. Morphometric optic nerve head parameters of 40 eyes of 40 patients with primary...

Descripción completa

Detalles Bibliográficos
Autores principales: Mariacher, Siegfried, Hipp, Stephanie, Wirthky, Robert, Blumenstock, Gunnar, Bartz-Schmidt, Karl-Ulrich, Ziemssen, Focke, Schiefer, Ulrich, Voykov, Bogomil, Januschowski, Kai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4904126/
https://www.ncbi.nlm.nih.gov/pubmed/27313870
http://dx.doi.org/10.1155/2016/4764857
_version_ 1782437101562757120
author Mariacher, Siegfried
Hipp, Stephanie
Wirthky, Robert
Blumenstock, Gunnar
Bartz-Schmidt, Karl-Ulrich
Ziemssen, Focke
Schiefer, Ulrich
Voykov, Bogomil
Januschowski, Kai
author_facet Mariacher, Siegfried
Hipp, Stephanie
Wirthky, Robert
Blumenstock, Gunnar
Bartz-Schmidt, Karl-Ulrich
Ziemssen, Focke
Schiefer, Ulrich
Voykov, Bogomil
Januschowski, Kai
author_sort Mariacher, Siegfried
collection PubMed
description Purpose. To investigate the agreement between morphometric optic nerve head parameters assessed with the confocal laser ophthalmoscope HRT III and the stereoscopic fundus camera Kowa nonmyd WX3D retrospectively. Methods. Morphometric optic nerve head parameters of 40 eyes of 40 patients with primary open angle glaucoma were analyzed regarding their vertical cup-to-disc-ratio (CDR). Vertical CDR, disc area, cup volume, rim volume, and maximum cup depth were assessed with both devices by one examiner. Mean bias and limits of agreement (95% CI) were obtained using scatter plots and Bland-Altman analysis. Results. Overall vertical CDR comparison between HRT III and Kowa nonmyd WX3D measurements showed a mean difference (limits of agreement) of −0.06 (−0.36 to 0.24). For the CDR < 0.5 group (n = 24) mean difference in vertical CDR was −0.14 (−0.34 to 0.06) and for the CDR ≥ 0.5 group (n = 16) 0.06 (−0.21 to 0.34). Conclusion. This study showed a good agreement between Kowa nonmyd WX3D and HRT III with regard to widely used optic nerve head parameters in patients with glaucomatous optic neuropathy. However, data from Kowa nonmyd WX3D exhibited the tendency to measure larger CDR values than HRT III in the group with CDR < 0.5 group and lower CDR values in the group with CDR ≥ 0.5.
format Online
Article
Text
id pubmed-4904126
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-49041262016-06-16 Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III) Mariacher, Siegfried Hipp, Stephanie Wirthky, Robert Blumenstock, Gunnar Bartz-Schmidt, Karl-Ulrich Ziemssen, Focke Schiefer, Ulrich Voykov, Bogomil Januschowski, Kai J Ophthalmol Research Article Purpose. To investigate the agreement between morphometric optic nerve head parameters assessed with the confocal laser ophthalmoscope HRT III and the stereoscopic fundus camera Kowa nonmyd WX3D retrospectively. Methods. Morphometric optic nerve head parameters of 40 eyes of 40 patients with primary open angle glaucoma were analyzed regarding their vertical cup-to-disc-ratio (CDR). Vertical CDR, disc area, cup volume, rim volume, and maximum cup depth were assessed with both devices by one examiner. Mean bias and limits of agreement (95% CI) were obtained using scatter plots and Bland-Altman analysis. Results. Overall vertical CDR comparison between HRT III and Kowa nonmyd WX3D measurements showed a mean difference (limits of agreement) of −0.06 (−0.36 to 0.24). For the CDR < 0.5 group (n = 24) mean difference in vertical CDR was −0.14 (−0.34 to 0.06) and for the CDR ≥ 0.5 group (n = 16) 0.06 (−0.21 to 0.34). Conclusion. This study showed a good agreement between Kowa nonmyd WX3D and HRT III with regard to widely used optic nerve head parameters in patients with glaucomatous optic neuropathy. However, data from Kowa nonmyd WX3D exhibited the tendency to measure larger CDR values than HRT III in the group with CDR < 0.5 group and lower CDR values in the group with CDR ≥ 0.5. Hindawi Publishing Corporation 2016 2016-05-30 /pmc/articles/PMC4904126/ /pubmed/27313870 http://dx.doi.org/10.1155/2016/4764857 Text en Copyright © 2016 Siegfried Mariacher et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Mariacher, Siegfried
Hipp, Stephanie
Wirthky, Robert
Blumenstock, Gunnar
Bartz-Schmidt, Karl-Ulrich
Ziemssen, Focke
Schiefer, Ulrich
Voykov, Bogomil
Januschowski, Kai
Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III)
title Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III)
title_full Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III)
title_fullStr Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III)
title_full_unstemmed Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III)
title_short Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III)
title_sort morphometric optic nerve head analysis in glaucoma patients: a comparison between the simultaneous nonmydriatic stereoscopic fundus camera (kowa nonmyd wx3d) and the heidelberg scanning laser ophthalmoscope (hrt iii)
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4904126/
https://www.ncbi.nlm.nih.gov/pubmed/27313870
http://dx.doi.org/10.1155/2016/4764857
work_keys_str_mv AT mariachersiegfried morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii
AT hippstephanie morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii
AT wirthkyrobert morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii
AT blumenstockgunnar morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii
AT bartzschmidtkarlulrich morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii
AT ziemssenfocke morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii
AT schieferulrich morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii
AT voykovbogomil morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii
AT januschowskikai morphometricopticnerveheadanalysisinglaucomapatientsacomparisonbetweenthesimultaneousnonmydriaticstereoscopicfunduscamerakowanonmydwx3dandtheheidelbergscanninglaserophthalmoscopehrtiii