Cargando…
Magnetic Resonance Imaging of the Small Bowel in Crohn's Disease: A Systematic Review and Meta-Analysis
Introduction. Crohn's disease is most commonly found in the terminal ileum and colonic region. Magnetic resonance has become a useful modality for assessing small bowel activity. In this study, we performed a systematic review and meta-analysis on the use of MR in detecting small bowel activity...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4904647/ https://www.ncbi.nlm.nih.gov/pubmed/27446869 http://dx.doi.org/10.1155/2016/7857352 |
_version_ | 1782437183190204416 |
---|---|
author | Ahmed, Osman Rodrigues, David Mario Nguyen, Geoffrey C. |
author_facet | Ahmed, Osman Rodrigues, David Mario Nguyen, Geoffrey C. |
author_sort | Ahmed, Osman |
collection | PubMed |
description | Introduction. Crohn's disease is most commonly found in the terminal ileum and colonic region. Magnetic resonance has become a useful modality for assessing small bowel activity. In this study, we performed a systematic review and meta-analysis on the use of MR in detecting small bowel activity as well as extramural complications in Crohn's patients. Methods. Two independent reviewers sorted through articles until October 2, 2014. We included both studies providing raw data for pooling and studies without raw data. Sensitivity, specificity, likelihood ratios, and 95% confidence intervals were calculated for each study. Results. There were 27 included studies, of which 19 were included in the pooled analysis. Pooled analysis of the 19 studies (1020 patients) with raw data revealed a sensitivity of 0.88 (95% CI 0.86 to 0.91) and specificity was 0.88 (95% CI 0.84 to 0.91). In regard to detecting stenosis, pooled sensitivity was 0.65 (95% CI 0.53 to 0.76) and specificity was 0.93 (95% CI 0.89 to 0.96). Conclusion. MR imaging provides a reliable alternative in detecting small bowel activity in patients with Crohn's disease. Its advantages include high diagnostic accuracy and no radiation exposure while its disadvantages include high cost and limited availability. |
format | Online Article Text |
id | pubmed-4904647 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-49046472016-06-30 Magnetic Resonance Imaging of the Small Bowel in Crohn's Disease: A Systematic Review and Meta-Analysis Ahmed, Osman Rodrigues, David Mario Nguyen, Geoffrey C. Can J Gastroenterol Hepatol Review Article Introduction. Crohn's disease is most commonly found in the terminal ileum and colonic region. Magnetic resonance has become a useful modality for assessing small bowel activity. In this study, we performed a systematic review and meta-analysis on the use of MR in detecting small bowel activity as well as extramural complications in Crohn's patients. Methods. Two independent reviewers sorted through articles until October 2, 2014. We included both studies providing raw data for pooling and studies without raw data. Sensitivity, specificity, likelihood ratios, and 95% confidence intervals were calculated for each study. Results. There were 27 included studies, of which 19 were included in the pooled analysis. Pooled analysis of the 19 studies (1020 patients) with raw data revealed a sensitivity of 0.88 (95% CI 0.86 to 0.91) and specificity was 0.88 (95% CI 0.84 to 0.91). In regard to detecting stenosis, pooled sensitivity was 0.65 (95% CI 0.53 to 0.76) and specificity was 0.93 (95% CI 0.89 to 0.96). Conclusion. MR imaging provides a reliable alternative in detecting small bowel activity in patients with Crohn's disease. Its advantages include high diagnostic accuracy and no radiation exposure while its disadvantages include high cost and limited availability. Hindawi Publishing Corporation 2016 2016-04-21 /pmc/articles/PMC4904647/ /pubmed/27446869 http://dx.doi.org/10.1155/2016/7857352 Text en Copyright © 2016 Osman Ahmed et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Article Ahmed, Osman Rodrigues, David Mario Nguyen, Geoffrey C. Magnetic Resonance Imaging of the Small Bowel in Crohn's Disease: A Systematic Review and Meta-Analysis |
title | Magnetic Resonance Imaging of the Small Bowel in Crohn's Disease: A Systematic Review and Meta-Analysis |
title_full | Magnetic Resonance Imaging of the Small Bowel in Crohn's Disease: A Systematic Review and Meta-Analysis |
title_fullStr | Magnetic Resonance Imaging of the Small Bowel in Crohn's Disease: A Systematic Review and Meta-Analysis |
title_full_unstemmed | Magnetic Resonance Imaging of the Small Bowel in Crohn's Disease: A Systematic Review and Meta-Analysis |
title_short | Magnetic Resonance Imaging of the Small Bowel in Crohn's Disease: A Systematic Review and Meta-Analysis |
title_sort | magnetic resonance imaging of the small bowel in crohn's disease: a systematic review and meta-analysis |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4904647/ https://www.ncbi.nlm.nih.gov/pubmed/27446869 http://dx.doi.org/10.1155/2016/7857352 |
work_keys_str_mv | AT ahmedosman magneticresonanceimagingofthesmallbowelincrohnsdiseaseasystematicreviewandmetaanalysis AT rodriguesdavidmario magneticresonanceimagingofthesmallbowelincrohnsdiseaseasystematicreviewandmetaanalysis AT nguyengeoffreyc magneticresonanceimagingofthesmallbowelincrohnsdiseaseasystematicreviewandmetaanalysis |