Late onset endophthalmitis associated with unexposed glaucoma valved drainage device()

We report an extremely rare presentation of late-onset endophthalmitis in a young adult patient with an unexposed Ahmed tube implant. The implant was inserted 11 years prior to presentation. There was no history of trauma or any obvious exposure on clinical examination and the tube plate was filled...

Descripción completa

Detalles Bibliográficos
Autores principales: AlHadlaq, Abdulaziz, AlMalki, Salem, AlShahwan, Sami
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4908096/
https://www.ncbi.nlm.nih.gov/pubmed/27330390
http://dx.doi.org/10.1016/j.sjopt.2015.12.005
_version_ 1782437619511066624
author AlHadlaq, Abdulaziz
AlMalki, Salem
AlShahwan, Sami
author_facet AlHadlaq, Abdulaziz
AlMalki, Salem
AlShahwan, Sami
author_sort AlHadlaq, Abdulaziz
collection PubMed
description We report an extremely rare presentation of late-onset endophthalmitis in a young adult patient with an unexposed Ahmed tube implant. The implant was inserted 11 years prior to presentation. There was no history of trauma or any obvious exposure on clinical examination and the tube plate was filled with purulent material. After aqueous and vitreous tap, the patient underwent intracameral, intravitreal subconjunctival antibiotic injections and was started on systemic antibiotics with good response. Endophthalmitis associated with tube drainage device can present as late as 11 years and even without an unexposed tube.
format Online
Article
Text
id pubmed-4908096
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-49080962016-06-21 Late onset endophthalmitis associated with unexposed glaucoma valved drainage device() AlHadlaq, Abdulaziz AlMalki, Salem AlShahwan, Sami Saudi J Ophthalmol Case Report We report an extremely rare presentation of late-onset endophthalmitis in a young adult patient with an unexposed Ahmed tube implant. The implant was inserted 11 years prior to presentation. There was no history of trauma or any obvious exposure on clinical examination and the tube plate was filled with purulent material. After aqueous and vitreous tap, the patient underwent intracameral, intravitreal subconjunctival antibiotic injections and was started on systemic antibiotics with good response. Endophthalmitis associated with tube drainage device can present as late as 11 years and even without an unexposed tube. Elsevier 2016 2015-12-28 /pmc/articles/PMC4908096/ /pubmed/27330390 http://dx.doi.org/10.1016/j.sjopt.2015.12.005 Text en © 2016 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
AlHadlaq, Abdulaziz
AlMalki, Salem
AlShahwan, Sami
Late onset endophthalmitis associated with unexposed glaucoma valved drainage device()
title Late onset endophthalmitis associated with unexposed glaucoma valved drainage device()
title_full Late onset endophthalmitis associated with unexposed glaucoma valved drainage device()
title_fullStr Late onset endophthalmitis associated with unexposed glaucoma valved drainage device()
title_full_unstemmed Late onset endophthalmitis associated with unexposed glaucoma valved drainage device()
title_short Late onset endophthalmitis associated with unexposed glaucoma valved drainage device()
title_sort late onset endophthalmitis associated with unexposed glaucoma valved drainage device()
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4908096/
https://www.ncbi.nlm.nih.gov/pubmed/27330390
http://dx.doi.org/10.1016/j.sjopt.2015.12.005
work_keys_str_mv AT alhadlaqabdulaziz lateonsetendophthalmitisassociatedwithunexposedglaucomavalveddrainagedevice
AT almalkisalem lateonsetendophthalmitisassociatedwithunexposedglaucomavalveddrainagedevice
AT alshahwansami lateonsetendophthalmitisassociatedwithunexposedglaucomavalveddrainagedevice