Cargando…
A Radiometer for Precision Coherent Radiation Measurements
A radiometer has been designed for precision colierent radiation measurements and tested for long-term repeatability at wavelengths of 488 and 633 nm. The radiometer consists of a pn silicon photodiode maintained in a nitrogen atmosphere with a quartz window designed to eliminate interference proble...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
1992
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4909167/ https://www.ncbi.nlm.nih.gov/pubmed/28053435 http://dx.doi.org/10.6028/jres.097.012 |
_version_ | 1782437789308026880 |
---|---|
author | Thomas, Douglas B. Zalewski, Edward F. |
author_facet | Thomas, Douglas B. Zalewski, Edward F. |
author_sort | Thomas, Douglas B. |
collection | PubMed |
description | A radiometer has been designed for precision colierent radiation measurements and tested for long-term repeatability at wavelengths of 488 and 633 nm. The radiometer consists of a pn silicon photodiode maintained in a nitrogen atmosphere with a quartz window designed to eliminate interference problems. Ratio measurements between the radiometer and an absolute type detector were made over a period of 215 d. At 0.5 mW, the standard deviations were 0.008% and 0.009% at 488 and 633 nm, respectively. The maximum deviations from the mean were 0.016% and 0.015% at the respective wavelengths. Measurements were also made on the radiometer with respect to angular and spatial uniformity and linearity. The high precision, simplicity, and portability of the radiometer suggest it for use as a transfer standard for radiometric measurements. |
format | Online Article Text |
id | pubmed-4909167 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1992 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-49091672017-01-04 A Radiometer for Precision Coherent Radiation Measurements Thomas, Douglas B. Zalewski, Edward F. J Res Natl Inst Stand Technol Article A radiometer has been designed for precision colierent radiation measurements and tested for long-term repeatability at wavelengths of 488 and 633 nm. The radiometer consists of a pn silicon photodiode maintained in a nitrogen atmosphere with a quartz window designed to eliminate interference problems. Ratio measurements between the radiometer and an absolute type detector were made over a period of 215 d. At 0.5 mW, the standard deviations were 0.008% and 0.009% at 488 and 633 nm, respectively. The maximum deviations from the mean were 0.016% and 0.015% at the respective wavelengths. Measurements were also made on the radiometer with respect to angular and spatial uniformity and linearity. The high precision, simplicity, and portability of the radiometer suggest it for use as a transfer standard for radiometric measurements. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1992 /pmc/articles/PMC4909167/ /pubmed/28053435 http://dx.doi.org/10.6028/jres.097.012 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Thomas, Douglas B. Zalewski, Edward F. A Radiometer for Precision Coherent Radiation Measurements |
title | A Radiometer for Precision Coherent Radiation Measurements |
title_full | A Radiometer for Precision Coherent Radiation Measurements |
title_fullStr | A Radiometer for Precision Coherent Radiation Measurements |
title_full_unstemmed | A Radiometer for Precision Coherent Radiation Measurements |
title_short | A Radiometer for Precision Coherent Radiation Measurements |
title_sort | radiometer for precision coherent radiation measurements |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4909167/ https://www.ncbi.nlm.nih.gov/pubmed/28053435 http://dx.doi.org/10.6028/jres.097.012 |
work_keys_str_mv | AT thomasdouglasb aradiometerforprecisioncoherentradiationmeasurements AT zalewskiedwardf aradiometerforprecisioncoherentradiationmeasurements AT thomasdouglasb radiometerforprecisioncoherentradiationmeasurements AT zalewskiedwardf radiometerforprecisioncoherentradiationmeasurements |