Cargando…

Drift Eliminating Designs for Non-Simultaneous Comparison Calibrations

The effects of drift on calibrations carried out by comparison have been studied at the National Institute of Standards and Technology for many years, and a number of strategies have been introduced to combat these effects. One strategy, the use of comparison designs which are inherently immune to l...

Descripción completa

Detalles Bibliográficos
Autor principal: Doiron, Ted
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1993
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4909179/
https://www.ncbi.nlm.nih.gov/pubmed/28053468
http://dx.doi.org/10.6028/jres.098.016
_version_ 1782437792208388096
author Doiron, Ted
author_facet Doiron, Ted
author_sort Doiron, Ted
collection PubMed
description The effects of drift on calibrations carried out by comparison have been studied at the National Institute of Standards and Technology for many years, and a number of strategies have been introduced to combat these effects. One strategy, the use of comparison designs which are inherently immune to linear drift, was developed specifically for mass comparison measurements. These techniques, developed for simultaneous comparisons, are extended to the case of non-simultaneous comparisons, such as gage block calibrations, where each artifact is measured separately, and the comparison is made mathematically from the individual measurements.
format Online
Article
Text
id pubmed-4909179
institution National Center for Biotechnology Information
language English
publishDate 1993
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-49091792017-01-04 Drift Eliminating Designs for Non-Simultaneous Comparison Calibrations Doiron, Ted J Res Natl Inst Stand Technol Article The effects of drift on calibrations carried out by comparison have been studied at the National Institute of Standards and Technology for many years, and a number of strategies have been introduced to combat these effects. One strategy, the use of comparison designs which are inherently immune to linear drift, was developed specifically for mass comparison measurements. These techniques, developed for simultaneous comparisons, are extended to the case of non-simultaneous comparisons, such as gage block calibrations, where each artifact is measured separately, and the comparison is made mathematically from the individual measurements. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1993 /pmc/articles/PMC4909179/ /pubmed/28053468 http://dx.doi.org/10.6028/jres.098.016 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Doiron, Ted
Drift Eliminating Designs for Non-Simultaneous Comparison Calibrations
title Drift Eliminating Designs for Non-Simultaneous Comparison Calibrations
title_full Drift Eliminating Designs for Non-Simultaneous Comparison Calibrations
title_fullStr Drift Eliminating Designs for Non-Simultaneous Comparison Calibrations
title_full_unstemmed Drift Eliminating Designs for Non-Simultaneous Comparison Calibrations
title_short Drift Eliminating Designs for Non-Simultaneous Comparison Calibrations
title_sort drift eliminating designs for non-simultaneous comparison calibrations
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4909179/
https://www.ncbi.nlm.nih.gov/pubmed/28053468
http://dx.doi.org/10.6028/jres.098.016
work_keys_str_mv AT doironted drifteliminatingdesignsfornonsimultaneouscomparisoncalibrations