Cargando…
1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study
PURPOSE: The aim of this study was to first develop and use 1.0 s ultrafast magnetic resonance imaging (MRI) to confirm the location of the femoral head in non-sedated infants with developmental dysplasia of the hip (DDH) after reduction with spica cast application in clinical settings. METHODS: The...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4909649/ https://www.ncbi.nlm.nih.gov/pubmed/27075984 http://dx.doi.org/10.1007/s11832-016-0734-8 |
_version_ | 1782437851529478144 |
---|---|
author | Fukuda, Atsushi Fukiage, Kenichi Futami, Tohru Miyati, Tosiaki |
author_facet | Fukuda, Atsushi Fukiage, Kenichi Futami, Tohru Miyati, Tosiaki |
author_sort | Fukuda, Atsushi |
collection | PubMed |
description | PURPOSE: The aim of this study was to first develop and use 1.0 s ultrafast magnetic resonance imaging (MRI) to confirm the location of the femoral head in non-sedated infants with developmental dysplasia of the hip (DDH) after reduction with spica cast application in clinical settings. METHODS: The ultrafast acquisition was achieved by employing a balanced steady-state free precession sequence and immobilizing the patient with dedicated sandbags. On completion of the ultrafast MRI study, all infants were sedated for conventional MRI scanning. Two orthopaedic surgeons retrospectively evaluated the image quality, result of the reduction and total MRI study time (including patient immobilization, coil setup, and scanning) in 14 DDHs of 13 infants (one with bilateral DDHs). RESULTS: Both reviewers stated that there were no motion artefacts for non-sedated infants during the ultrafast MRI and that the quality of both the ultrafast and conventional MRI images were acceptable to assess the femoral head location. Assessment of the reduction procedure resulted in two hips being categorized as ‘incomplete reduction’ requiring a re-reduction procedure. The total study time of ultrafast and conventional MRI was 6 ± 1 min and 14 ± 3 min, respectively (P < 0.001). No complications due to sedation, such as hypoxia, were reported. The average sedation waiting time was 1 h 25 min ± 34 min. CONCLUSION: The ultrafast MRI procedure reported here can be readily employed to confirm the location of the femoral head in infants with DDHs, without the use of any sedation. |
format | Online Article Text |
id | pubmed-4909649 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-49096492016-07-01 1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study Fukuda, Atsushi Fukiage, Kenichi Futami, Tohru Miyati, Tosiaki J Child Orthop Original Clinical Article PURPOSE: The aim of this study was to first develop and use 1.0 s ultrafast magnetic resonance imaging (MRI) to confirm the location of the femoral head in non-sedated infants with developmental dysplasia of the hip (DDH) after reduction with spica cast application in clinical settings. METHODS: The ultrafast acquisition was achieved by employing a balanced steady-state free precession sequence and immobilizing the patient with dedicated sandbags. On completion of the ultrafast MRI study, all infants were sedated for conventional MRI scanning. Two orthopaedic surgeons retrospectively evaluated the image quality, result of the reduction and total MRI study time (including patient immobilization, coil setup, and scanning) in 14 DDHs of 13 infants (one with bilateral DDHs). RESULTS: Both reviewers stated that there were no motion artefacts for non-sedated infants during the ultrafast MRI and that the quality of both the ultrafast and conventional MRI images were acceptable to assess the femoral head location. Assessment of the reduction procedure resulted in two hips being categorized as ‘incomplete reduction’ requiring a re-reduction procedure. The total study time of ultrafast and conventional MRI was 6 ± 1 min and 14 ± 3 min, respectively (P < 0.001). No complications due to sedation, such as hypoxia, were reported. The average sedation waiting time was 1 h 25 min ± 34 min. CONCLUSION: The ultrafast MRI procedure reported here can be readily employed to confirm the location of the femoral head in infants with DDHs, without the use of any sedation. Springer Berlin Heidelberg 2016-04-13 2016-06 /pmc/articles/PMC4909649/ /pubmed/27075984 http://dx.doi.org/10.1007/s11832-016-0734-8 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Clinical Article Fukuda, Atsushi Fukiage, Kenichi Futami, Tohru Miyati, Tosiaki 1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study |
title | 1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study |
title_full | 1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study |
title_fullStr | 1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study |
title_full_unstemmed | 1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study |
title_short | 1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study |
title_sort | 1.0 s ultrafast mri in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study |
topic | Original Clinical Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4909649/ https://www.ncbi.nlm.nih.gov/pubmed/27075984 http://dx.doi.org/10.1007/s11832-016-0734-8 |
work_keys_str_mv | AT fukudaatsushi 10sultrafastmriinnonsedatedinfantsafterreductionwithspicacastingfordevelopmentaldysplasiaofthehipafeasibilitystudy AT fukiagekenichi 10sultrafastmriinnonsedatedinfantsafterreductionwithspicacastingfordevelopmentaldysplasiaofthehipafeasibilitystudy AT futamitohru 10sultrafastmriinnonsedatedinfantsafterreductionwithspicacastingfordevelopmentaldysplasiaofthehipafeasibilitystudy AT miyatitosiaki 10sultrafastmriinnonsedatedinfantsafterreductionwithspicacastingfordevelopmentaldysplasiaofthehipafeasibilitystudy |