Cargando…

1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study

PURPOSE: The aim of this study was to first develop and use 1.0 s ultrafast magnetic resonance imaging (MRI) to confirm the location of the femoral head in non-sedated infants with developmental dysplasia of the hip (DDH) after reduction with spica cast application in clinical settings. METHODS: The...

Descripción completa

Detalles Bibliográficos
Autores principales: Fukuda, Atsushi, Fukiage, Kenichi, Futami, Tohru, Miyati, Tosiaki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4909649/
https://www.ncbi.nlm.nih.gov/pubmed/27075984
http://dx.doi.org/10.1007/s11832-016-0734-8
_version_ 1782437851529478144
author Fukuda, Atsushi
Fukiage, Kenichi
Futami, Tohru
Miyati, Tosiaki
author_facet Fukuda, Atsushi
Fukiage, Kenichi
Futami, Tohru
Miyati, Tosiaki
author_sort Fukuda, Atsushi
collection PubMed
description PURPOSE: The aim of this study was to first develop and use 1.0 s ultrafast magnetic resonance imaging (MRI) to confirm the location of the femoral head in non-sedated infants with developmental dysplasia of the hip (DDH) after reduction with spica cast application in clinical settings. METHODS: The ultrafast acquisition was achieved by employing a balanced steady-state free precession sequence and immobilizing the patient with dedicated sandbags. On completion of the ultrafast MRI study, all infants were sedated for conventional MRI scanning. Two orthopaedic surgeons retrospectively evaluated the image quality, result of the reduction and total MRI study time (including patient immobilization, coil setup, and scanning) in 14 DDHs of 13 infants (one with bilateral DDHs). RESULTS: Both reviewers stated that there were no motion artefacts for non-sedated infants during the ultrafast MRI and that the quality of both the ultrafast and conventional MRI images were acceptable to assess the femoral head location. Assessment of the reduction procedure resulted in two hips being categorized as ‘incomplete reduction’ requiring a re-reduction procedure. The total study time of ultrafast and conventional MRI was 6 ± 1 min and 14 ± 3 min, respectively (P < 0.001). No complications due to sedation, such as hypoxia, were reported. The average sedation waiting time was 1 h 25 min ± 34 min. CONCLUSION: The ultrafast MRI procedure reported here can be readily employed to confirm the location of the femoral head in infants with DDHs, without the use of any sedation.
format Online
Article
Text
id pubmed-4909649
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-49096492016-07-01 1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study Fukuda, Atsushi Fukiage, Kenichi Futami, Tohru Miyati, Tosiaki J Child Orthop Original Clinical Article PURPOSE: The aim of this study was to first develop and use 1.0 s ultrafast magnetic resonance imaging (MRI) to confirm the location of the femoral head in non-sedated infants with developmental dysplasia of the hip (DDH) after reduction with spica cast application in clinical settings. METHODS: The ultrafast acquisition was achieved by employing a balanced steady-state free precession sequence and immobilizing the patient with dedicated sandbags. On completion of the ultrafast MRI study, all infants were sedated for conventional MRI scanning. Two orthopaedic surgeons retrospectively evaluated the image quality, result of the reduction and total MRI study time (including patient immobilization, coil setup, and scanning) in 14 DDHs of 13 infants (one with bilateral DDHs). RESULTS: Both reviewers stated that there were no motion artefacts for non-sedated infants during the ultrafast MRI and that the quality of both the ultrafast and conventional MRI images were acceptable to assess the femoral head location. Assessment of the reduction procedure resulted in two hips being categorized as ‘incomplete reduction’ requiring a re-reduction procedure. The total study time of ultrafast and conventional MRI was 6 ± 1 min and 14 ± 3 min, respectively (P < 0.001). No complications due to sedation, such as hypoxia, were reported. The average sedation waiting time was 1 h 25 min ± 34 min. CONCLUSION: The ultrafast MRI procedure reported here can be readily employed to confirm the location of the femoral head in infants with DDHs, without the use of any sedation. Springer Berlin Heidelberg 2016-04-13 2016-06 /pmc/articles/PMC4909649/ /pubmed/27075984 http://dx.doi.org/10.1007/s11832-016-0734-8 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Clinical Article
Fukuda, Atsushi
Fukiage, Kenichi
Futami, Tohru
Miyati, Tosiaki
1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study
title 1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study
title_full 1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study
title_fullStr 1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study
title_full_unstemmed 1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study
title_short 1.0 s Ultrafast MRI in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study
title_sort 1.0 s ultrafast mri in non-sedated infants after reduction with spica casting for developmental dysplasia of the hip: a feasibility study
topic Original Clinical Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4909649/
https://www.ncbi.nlm.nih.gov/pubmed/27075984
http://dx.doi.org/10.1007/s11832-016-0734-8
work_keys_str_mv AT fukudaatsushi 10sultrafastmriinnonsedatedinfantsafterreductionwithspicacastingfordevelopmentaldysplasiaofthehipafeasibilitystudy
AT fukiagekenichi 10sultrafastmriinnonsedatedinfantsafterreductionwithspicacastingfordevelopmentaldysplasiaofthehipafeasibilitystudy
AT futamitohru 10sultrafastmriinnonsedatedinfantsafterreductionwithspicacastingfordevelopmentaldysplasiaofthehipafeasibilitystudy
AT miyatitosiaki 10sultrafastmriinnonsedatedinfantsafterreductionwithspicacastingfordevelopmentaldysplasiaofthehipafeasibilitystudy