Interference of M-protein on prothrombin time test – case report

The aim of this report was to present a case of interference on prothrombin time (PT) test that directed further laboratory diagnostics and resulted with final detection of monoclonal gammopathy in an 88-year old man. Routine coagulation testing during medical examination at Emergency Department rev...

Descripción completa

Detalles Bibliográficos
Autores principales: Margetić, Sandra, Ćelap, Ivana, Dukić, Lora, Vukasović, Ines, Virović-Jukić, Lucija
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Croatian Society of Medical Biochemistry and Laboratory Medicine 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4910265/
https://www.ncbi.nlm.nih.gov/pubmed/27346971
http://dx.doi.org/10.11613/BM.2016.028