INTRODUCTION: The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. MATERIALS AND METHODS: 275 pathologic urine sp...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Croatian Society of Medical Biochemistry and Laboratory Medicine
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4910281/ https://www.ncbi.nlm.nih.gov/pubmed/27346967 http://dx.doi.org/10.11613/BM.2016.024 |
_version_ | 1782437988127473664 |
---|---|
author | Ekşioğlu, Merve Kaymak Madenci, Özlem Çakır Yücel, Nihal Elçi, Abdullah Turhan, Bülent Orhan, Gani Orçun, Asuman |
author_facet | Ekşioğlu, Merve Kaymak Madenci, Özlem Çakır Yücel, Nihal Elçi, Abdullah Turhan, Bülent Orhan, Gani Orçun, Asuman |
author_sort | Ekşioğlu, Merve Kaymak |
collection | PubMed |
description | INTRODUCTION: The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. MATERIALS AND METHODS: 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer® Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (κ), false positive (FP) and false negative (FN) rates were evaluated. κ > 0.8 was accepted as good agreement. RESULTS: Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. CONCLUSIONS: Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible. |
format | Online Article Text |
id | pubmed-4910281 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Croatian Society of Medical Biochemistry and Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-49102812016-06-24 The effectiveness of BD Vacutainer® Plus Urinalysis Preservative Tubes in preservation of urine for chemical strip analysis and particle counting Ekşioğlu, Merve Kaymak Madenci, Özlem Çakır Yücel, Nihal Elçi, Abdullah Turhan, Bülent Orhan, Gani Orçun, Asuman Biochem Med (Zagreb) Research Article INTRODUCTION: The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. MATERIALS AND METHODS: 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer® Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (κ), false positive (FP) and false negative (FN) rates were evaluated. κ > 0.8 was accepted as good agreement. RESULTS: Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. CONCLUSIONS: Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible. Croatian Society of Medical Biochemistry and Laboratory Medicine 2016-06-10 2016-06-10 /pmc/articles/PMC4910281/ /pubmed/27346967 http://dx.doi.org/10.11613/BM.2016.024 Text en |
spellingShingle | Research Article Ekşioğlu, Merve Kaymak Madenci, Özlem Çakır Yücel, Nihal Elçi, Abdullah Turhan, Bülent Orhan, Gani Orçun, Asuman The effectiveness of BD Vacutainer® Plus Urinalysis Preservative Tubes in preservation of urine for chemical strip analysis and particle counting |
title | The effectiveness of BD Vacutainer® Plus Urinalysis Preservative Tubes in preservation of urine for chemical strip analysis and particle counting |
title_full | The effectiveness of BD Vacutainer® Plus Urinalysis Preservative Tubes in preservation of urine for chemical strip analysis and particle counting |
title_fullStr | The effectiveness of BD Vacutainer® Plus Urinalysis Preservative Tubes in preservation of urine for chemical strip analysis and particle counting |
title_full_unstemmed | The effectiveness of BD Vacutainer® Plus Urinalysis Preservative Tubes in preservation of urine for chemical strip analysis and particle counting |
title_short | The effectiveness of BD Vacutainer® Plus Urinalysis Preservative Tubes in preservation of urine for chemical strip analysis and particle counting |
title_sort | effectiveness of bd vacutainer® plus urinalysis preservative tubes in preservation of urine for chemical strip analysis and particle counting |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4910281/ https://www.ncbi.nlm.nih.gov/pubmed/27346967 http://dx.doi.org/10.11613/BM.2016.024 |
work_keys_str_mv | AT eksioglumervekaymak theeffectivenessofbdvacutainerplusurinalysispreservativetubesinpreservationofurineforchemicalstripanalysisandparticlecounting AT madenciozlemcakır theeffectivenessofbdvacutainerplusurinalysispreservativetubesinpreservationofurineforchemicalstripanalysisandparticlecounting AT yucelnihal theeffectivenessofbdvacutainerplusurinalysispreservativetubesinpreservationofurineforchemicalstripanalysisandparticlecounting AT elciabdullah theeffectivenessofbdvacutainerplusurinalysispreservativetubesinpreservationofurineforchemicalstripanalysisandparticlecounting AT turhanbulent theeffectivenessofbdvacutainerplusurinalysispreservativetubesinpreservationofurineforchemicalstripanalysisandparticlecounting AT orhangani theeffectivenessofbdvacutainerplusurinalysispreservativetubesinpreservationofurineforchemicalstripanalysisandparticlecounting AT orcunasuman theeffectivenessofbdvacutainerplusurinalysispreservativetubesinpreservationofurineforchemicalstripanalysisandparticlecounting AT eksioglumervekaymak effectivenessofbdvacutainerplusurinalysispreservativetubesinpreservationofurineforchemicalstripanalysisandparticlecounting AT madenciozlemcakır effectivenessofbdvacutainerplusurinalysispreservativetubesinpreservationofurineforchemicalstripanalysisandparticlecounting AT yucelnihal effectivenessofbdvacutainerplusurinalysispreservativetubesinpreservationofurineforchemicalstripanalysisandparticlecounting AT elciabdullah effectivenessofbdvacutainerplusurinalysispreservativetubesinpreservationofurineforchemicalstripanalysisandparticlecounting AT turhanbulent effectivenessofbdvacutainerplusurinalysispreservativetubesinpreservationofurineforchemicalstripanalysisandparticlecounting AT orhangani effectivenessofbdvacutainerplusurinalysispreservativetubesinpreservationofurineforchemicalstripanalysisandparticlecounting AT orcunasuman effectivenessofbdvacutainerplusurinalysispreservativetubesinpreservationofurineforchemicalstripanalysisandparticlecounting |