Cargando…

Assessment of variation in depth of brachial plexus using ultrasound for supraclavicular brachial plexus block in patients undergoing elective upper limb surgery

BACKGROUND AND AIMS: Supraclavicular approach to the brachial plexus may be associated with complications such as pneumothorax, inadvertent vascular puncture, inter-scalene block and neurovascular injuries. The present study was conceived to find out the variation in depth of brachial plexus to sugg...

Descripción completa

Detalles Bibliográficos
Autores principales: Mistry, Tuhin, Mangal, Vandana, Sharma, Gaurav, Agrawal, Aachu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4910478/
https://www.ncbi.nlm.nih.gov/pubmed/27330200
http://dx.doi.org/10.4103/0019-5049.183385
_version_ 1782438017185611776
author Mistry, Tuhin
Mangal, Vandana
Sharma, Gaurav
Agrawal, Aachu
author_facet Mistry, Tuhin
Mangal, Vandana
Sharma, Gaurav
Agrawal, Aachu
author_sort Mistry, Tuhin
collection PubMed
description BACKGROUND AND AIMS: Supraclavicular approach to the brachial plexus may be associated with complications such as pneumothorax, inadvertent vascular puncture, inter-scalene block and neurovascular injuries. The present study was conceived to find out the variation in depth of brachial plexus to suggest the minimum length of needle required to effectively perform the block, thus preventing possible complications. METHODS: After approval from our Institutional Ethical Committee, informed and written consent was obtained from each of the ninety American Society of Anesthesiologists Physical Status I and II patients recruited, of either sex in the age group of 20–50 years. Supraclavicular fossa was scanned using a high-frequency linear probe, and the distances (shortest distance [SD] from skin to the most superficial neural element and longest distance [LD] from skin to the most deep neural element) were measured using on-screen callipers on optimal frozen image. Pearson correlation was used to find out the relation between these two distances and demographic parameters. RESULTS: Mean SD was 0.60 ± 0.262 cm, and mean LD was found to be 1.34 ± 0.385 cm. We observed significant correlation between these two distances with weight and body mass index (BMI). CONCLUSION: Significant correlation was observed between SD and LD with weight and BMI. We suggest that a needle with a shaft length of 3 cm will be sufficient to reach the sheath of the brachial plexus during performance of the block.
format Online
Article
Text
id pubmed-4910478
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-49104782016-06-17 Assessment of variation in depth of brachial plexus using ultrasound for supraclavicular brachial plexus block in patients undergoing elective upper limb surgery Mistry, Tuhin Mangal, Vandana Sharma, Gaurav Agrawal, Aachu Indian J Anaesth Original Article BACKGROUND AND AIMS: Supraclavicular approach to the brachial plexus may be associated with complications such as pneumothorax, inadvertent vascular puncture, inter-scalene block and neurovascular injuries. The present study was conceived to find out the variation in depth of brachial plexus to suggest the minimum length of needle required to effectively perform the block, thus preventing possible complications. METHODS: After approval from our Institutional Ethical Committee, informed and written consent was obtained from each of the ninety American Society of Anesthesiologists Physical Status I and II patients recruited, of either sex in the age group of 20–50 years. Supraclavicular fossa was scanned using a high-frequency linear probe, and the distances (shortest distance [SD] from skin to the most superficial neural element and longest distance [LD] from skin to the most deep neural element) were measured using on-screen callipers on optimal frozen image. Pearson correlation was used to find out the relation between these two distances and demographic parameters. RESULTS: Mean SD was 0.60 ± 0.262 cm, and mean LD was found to be 1.34 ± 0.385 cm. We observed significant correlation between these two distances with weight and body mass index (BMI). CONCLUSION: Significant correlation was observed between SD and LD with weight and BMI. We suggest that a needle with a shaft length of 3 cm will be sufficient to reach the sheath of the brachial plexus during performance of the block. Medknow Publications & Media Pvt Ltd 2016-06 /pmc/articles/PMC4910478/ /pubmed/27330200 http://dx.doi.org/10.4103/0019-5049.183385 Text en Copyright: © Indian Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution NonCommercial ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Mistry, Tuhin
Mangal, Vandana
Sharma, Gaurav
Agrawal, Aachu
Assessment of variation in depth of brachial plexus using ultrasound for supraclavicular brachial plexus block in patients undergoing elective upper limb surgery
title Assessment of variation in depth of brachial plexus using ultrasound for supraclavicular brachial plexus block in patients undergoing elective upper limb surgery
title_full Assessment of variation in depth of brachial plexus using ultrasound for supraclavicular brachial plexus block in patients undergoing elective upper limb surgery
title_fullStr Assessment of variation in depth of brachial plexus using ultrasound for supraclavicular brachial plexus block in patients undergoing elective upper limb surgery
title_full_unstemmed Assessment of variation in depth of brachial plexus using ultrasound for supraclavicular brachial plexus block in patients undergoing elective upper limb surgery
title_short Assessment of variation in depth of brachial plexus using ultrasound for supraclavicular brachial plexus block in patients undergoing elective upper limb surgery
title_sort assessment of variation in depth of brachial plexus using ultrasound for supraclavicular brachial plexus block in patients undergoing elective upper limb surgery
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4910478/
https://www.ncbi.nlm.nih.gov/pubmed/27330200
http://dx.doi.org/10.4103/0019-5049.183385
work_keys_str_mv AT mistrytuhin assessmentofvariationindepthofbrachialplexususingultrasoundforsupraclavicularbrachialplexusblockinpatientsundergoingelectiveupperlimbsurgery
AT mangalvandana assessmentofvariationindepthofbrachialplexususingultrasoundforsupraclavicularbrachialplexusblockinpatientsundergoingelectiveupperlimbsurgery
AT sharmagaurav assessmentofvariationindepthofbrachialplexususingultrasoundforsupraclavicularbrachialplexusblockinpatientsundergoingelectiveupperlimbsurgery
AT agrawalaachu assessmentofvariationindepthofbrachialplexususingultrasoundforsupraclavicularbrachialplexusblockinpatientsundergoingelectiveupperlimbsurgery