Cargando…

Accuracy of Dolphin visual treatment objective (VTO) prediction software on class III patients treated with maxillary advancement and mandibular setback

BACKGROUND: Dolphin® visual treatment objective (VTO) prediction software is routinely utilized by orthodontists during the treatment planning of orthognathic cases to help predict post-surgical soft tissue changes. Although surgical soft tissue prediction is considered to be a vital tool, its accur...

Descripción completa

Detalles Bibliográficos
Autores principales: Peterman, Robert J., Jiang, Shuying, Johe, Rene, Mukherjee, Padma M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4911347/
https://www.ncbi.nlm.nih.gov/pubmed/27312722
http://dx.doi.org/10.1186/s40510-016-0132-2
_version_ 1782438109361733632
author Peterman, Robert J.
Jiang, Shuying
Johe, Rene
Mukherjee, Padma M.
author_facet Peterman, Robert J.
Jiang, Shuying
Johe, Rene
Mukherjee, Padma M.
author_sort Peterman, Robert J.
collection PubMed
description BACKGROUND: Dolphin® visual treatment objective (VTO) prediction software is routinely utilized by orthodontists during the treatment planning of orthognathic cases to help predict post-surgical soft tissue changes. Although surgical soft tissue prediction is considered to be a vital tool, its accuracy is not well understood in tow-jaw surgical procedures. The objective of this study was to quantify the accuracy of Dolphin Imaging’s VTO soft tissue prediction software on class III patients treated with maxillary advancement and mandibular setback and to validate the efficacy of the software in such complex cases. METHODS: This retrospective study analyzed the records of 14 patients treated with comprehensive orthodontics in conjunction with two-jaw orthognathic surgery. Pre- and post-treatment radiographs were traced and superimposed to determine the actual skeletal movements achieved in surgery. This information was then used to simulate surgery in the software and generate a final soft tissue patient profile prediction. Prediction images were then compared to the actual post-treatment profile photos to determine differences. RESULTS: Dolphin Imaging’s software was determined to be accurate within an error range of +/− 2 mm in the X-axis at most landmarks. The lower lip predictions were most inaccurate. CONCLUSIONS: Clinically, the observed error suggests that the VTO may be used for demonstration and communication with a patient or consulting practitioner. However, Dolphin should not be useful for precise treatment planning of surgical movements. This program should be used with caution to prevent unrealistic patient expectations and dissatisfaction.
format Online
Article
Text
id pubmed-4911347
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-49113472016-07-06 Accuracy of Dolphin visual treatment objective (VTO) prediction software on class III patients treated with maxillary advancement and mandibular setback Peterman, Robert J. Jiang, Shuying Johe, Rene Mukherjee, Padma M. Prog Orthod Research BACKGROUND: Dolphin® visual treatment objective (VTO) prediction software is routinely utilized by orthodontists during the treatment planning of orthognathic cases to help predict post-surgical soft tissue changes. Although surgical soft tissue prediction is considered to be a vital tool, its accuracy is not well understood in tow-jaw surgical procedures. The objective of this study was to quantify the accuracy of Dolphin Imaging’s VTO soft tissue prediction software on class III patients treated with maxillary advancement and mandibular setback and to validate the efficacy of the software in such complex cases. METHODS: This retrospective study analyzed the records of 14 patients treated with comprehensive orthodontics in conjunction with two-jaw orthognathic surgery. Pre- and post-treatment radiographs were traced and superimposed to determine the actual skeletal movements achieved in surgery. This information was then used to simulate surgery in the software and generate a final soft tissue patient profile prediction. Prediction images were then compared to the actual post-treatment profile photos to determine differences. RESULTS: Dolphin Imaging’s software was determined to be accurate within an error range of +/− 2 mm in the X-axis at most landmarks. The lower lip predictions were most inaccurate. CONCLUSIONS: Clinically, the observed error suggests that the VTO may be used for demonstration and communication with a patient or consulting practitioner. However, Dolphin should not be useful for precise treatment planning of surgical movements. This program should be used with caution to prevent unrealistic patient expectations and dissatisfaction. Springer Berlin Heidelberg 2016-06-17 /pmc/articles/PMC4911347/ /pubmed/27312722 http://dx.doi.org/10.1186/s40510-016-0132-2 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Peterman, Robert J.
Jiang, Shuying
Johe, Rene
Mukherjee, Padma M.
Accuracy of Dolphin visual treatment objective (VTO) prediction software on class III patients treated with maxillary advancement and mandibular setback
title Accuracy of Dolphin visual treatment objective (VTO) prediction software on class III patients treated with maxillary advancement and mandibular setback
title_full Accuracy of Dolphin visual treatment objective (VTO) prediction software on class III patients treated with maxillary advancement and mandibular setback
title_fullStr Accuracy of Dolphin visual treatment objective (VTO) prediction software on class III patients treated with maxillary advancement and mandibular setback
title_full_unstemmed Accuracy of Dolphin visual treatment objective (VTO) prediction software on class III patients treated with maxillary advancement and mandibular setback
title_short Accuracy of Dolphin visual treatment objective (VTO) prediction software on class III patients treated with maxillary advancement and mandibular setback
title_sort accuracy of dolphin visual treatment objective (vto) prediction software on class iii patients treated with maxillary advancement and mandibular setback
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4911347/
https://www.ncbi.nlm.nih.gov/pubmed/27312722
http://dx.doi.org/10.1186/s40510-016-0132-2
work_keys_str_mv AT petermanrobertj accuracyofdolphinvisualtreatmentobjectivevtopredictionsoftwareonclassiiipatientstreatedwithmaxillaryadvancementandmandibularsetback
AT jiangshuying accuracyofdolphinvisualtreatmentobjectivevtopredictionsoftwareonclassiiipatientstreatedwithmaxillaryadvancementandmandibularsetback
AT joherene accuracyofdolphinvisualtreatmentobjectivevtopredictionsoftwareonclassiiipatientstreatedwithmaxillaryadvancementandmandibularsetback
AT mukherjeepadmam accuracyofdolphinvisualtreatmentobjectivevtopredictionsoftwareonclassiiipatientstreatedwithmaxillaryadvancementandmandibularsetback