Cargando…
Accuracy of Dolphin visual treatment objective (VTO) prediction software on class III patients treated with maxillary advancement and mandibular setback
BACKGROUND: Dolphin® visual treatment objective (VTO) prediction software is routinely utilized by orthodontists during the treatment planning of orthognathic cases to help predict post-surgical soft tissue changes. Although surgical soft tissue prediction is considered to be a vital tool, its accur...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4911347/ https://www.ncbi.nlm.nih.gov/pubmed/27312722 http://dx.doi.org/10.1186/s40510-016-0132-2 |
_version_ | 1782438109361733632 |
---|---|
author | Peterman, Robert J. Jiang, Shuying Johe, Rene Mukherjee, Padma M. |
author_facet | Peterman, Robert J. Jiang, Shuying Johe, Rene Mukherjee, Padma M. |
author_sort | Peterman, Robert J. |
collection | PubMed |
description | BACKGROUND: Dolphin® visual treatment objective (VTO) prediction software is routinely utilized by orthodontists during the treatment planning of orthognathic cases to help predict post-surgical soft tissue changes. Although surgical soft tissue prediction is considered to be a vital tool, its accuracy is not well understood in tow-jaw surgical procedures. The objective of this study was to quantify the accuracy of Dolphin Imaging’s VTO soft tissue prediction software on class III patients treated with maxillary advancement and mandibular setback and to validate the efficacy of the software in such complex cases. METHODS: This retrospective study analyzed the records of 14 patients treated with comprehensive orthodontics in conjunction with two-jaw orthognathic surgery. Pre- and post-treatment radiographs were traced and superimposed to determine the actual skeletal movements achieved in surgery. This information was then used to simulate surgery in the software and generate a final soft tissue patient profile prediction. Prediction images were then compared to the actual post-treatment profile photos to determine differences. RESULTS: Dolphin Imaging’s software was determined to be accurate within an error range of +/− 2 mm in the X-axis at most landmarks. The lower lip predictions were most inaccurate. CONCLUSIONS: Clinically, the observed error suggests that the VTO may be used for demonstration and communication with a patient or consulting practitioner. However, Dolphin should not be useful for precise treatment planning of surgical movements. This program should be used with caution to prevent unrealistic patient expectations and dissatisfaction. |
format | Online Article Text |
id | pubmed-4911347 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-49113472016-07-06 Accuracy of Dolphin visual treatment objective (VTO) prediction software on class III patients treated with maxillary advancement and mandibular setback Peterman, Robert J. Jiang, Shuying Johe, Rene Mukherjee, Padma M. Prog Orthod Research BACKGROUND: Dolphin® visual treatment objective (VTO) prediction software is routinely utilized by orthodontists during the treatment planning of orthognathic cases to help predict post-surgical soft tissue changes. Although surgical soft tissue prediction is considered to be a vital tool, its accuracy is not well understood in tow-jaw surgical procedures. The objective of this study was to quantify the accuracy of Dolphin Imaging’s VTO soft tissue prediction software on class III patients treated with maxillary advancement and mandibular setback and to validate the efficacy of the software in such complex cases. METHODS: This retrospective study analyzed the records of 14 patients treated with comprehensive orthodontics in conjunction with two-jaw orthognathic surgery. Pre- and post-treatment radiographs were traced and superimposed to determine the actual skeletal movements achieved in surgery. This information was then used to simulate surgery in the software and generate a final soft tissue patient profile prediction. Prediction images were then compared to the actual post-treatment profile photos to determine differences. RESULTS: Dolphin Imaging’s software was determined to be accurate within an error range of +/− 2 mm in the X-axis at most landmarks. The lower lip predictions were most inaccurate. CONCLUSIONS: Clinically, the observed error suggests that the VTO may be used for demonstration and communication with a patient or consulting practitioner. However, Dolphin should not be useful for precise treatment planning of surgical movements. This program should be used with caution to prevent unrealistic patient expectations and dissatisfaction. Springer Berlin Heidelberg 2016-06-17 /pmc/articles/PMC4911347/ /pubmed/27312722 http://dx.doi.org/10.1186/s40510-016-0132-2 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Research Peterman, Robert J. Jiang, Shuying Johe, Rene Mukherjee, Padma M. Accuracy of Dolphin visual treatment objective (VTO) prediction software on class III patients treated with maxillary advancement and mandibular setback |
title | Accuracy of Dolphin visual treatment objective (VTO) prediction software on class III patients treated with maxillary advancement and mandibular setback |
title_full | Accuracy of Dolphin visual treatment objective (VTO) prediction software on class III patients treated with maxillary advancement and mandibular setback |
title_fullStr | Accuracy of Dolphin visual treatment objective (VTO) prediction software on class III patients treated with maxillary advancement and mandibular setback |
title_full_unstemmed | Accuracy of Dolphin visual treatment objective (VTO) prediction software on class III patients treated with maxillary advancement and mandibular setback |
title_short | Accuracy of Dolphin visual treatment objective (VTO) prediction software on class III patients treated with maxillary advancement and mandibular setback |
title_sort | accuracy of dolphin visual treatment objective (vto) prediction software on class iii patients treated with maxillary advancement and mandibular setback |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4911347/ https://www.ncbi.nlm.nih.gov/pubmed/27312722 http://dx.doi.org/10.1186/s40510-016-0132-2 |
work_keys_str_mv | AT petermanrobertj accuracyofdolphinvisualtreatmentobjectivevtopredictionsoftwareonclassiiipatientstreatedwithmaxillaryadvancementandmandibularsetback AT jiangshuying accuracyofdolphinvisualtreatmentobjectivevtopredictionsoftwareonclassiiipatientstreatedwithmaxillaryadvancementandmandibularsetback AT joherene accuracyofdolphinvisualtreatmentobjectivevtopredictionsoftwareonclassiiipatientstreatedwithmaxillaryadvancementandmandibularsetback AT mukherjeepadmam accuracyofdolphinvisualtreatmentobjectivevtopredictionsoftwareonclassiiipatientstreatedwithmaxillaryadvancementandmandibularsetback |