Purpose: To evaluate LithoVue, the new single-use digital flexible ureteroscope, in a human cadaveric model and compare it with a nondisposable fiber optic and digital flexible ureteroscopes. Materials and Methods: LithoVue, a conventional fiber optic, and digital flexible ureteroscopes were each te...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Mary Ann Liebert, Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4913498/ https://www.ncbi.nlm.nih.gov/pubmed/27084572 http://dx.doi.org/10.1089/end.2016.0051 |
_version_ | 1782438411075846144 |
---|---|
author | Proietti, Silvia Dragos, Laurian Molina, Wilson Doizi, Steeve Giusti, Guido Traxer, Olivier |
author_facet | Proietti, Silvia Dragos, Laurian Molina, Wilson Doizi, Steeve Giusti, Guido Traxer, Olivier |
author_sort | Proietti, Silvia |
collection | PubMed |
description | Purpose: To evaluate LithoVue, the new single-use digital flexible ureteroscope, in a human cadaveric model and compare it with a nondisposable fiber optic and digital flexible ureteroscopes. Materials and Methods: LithoVue, a conventional fiber optic, and digital flexible ureteroscopes were each tested in four renal units of recently deceased female cadavers by three surgeons. The following parameters were analyzed: accessibility to the kidney and navigation of the entire collecting system with and without ureteral access sheath (UAS), lower pole access measuring the deflection of the ureteroscope with the working channel empty, and with inside two different baskets and laser fibers. A subjective evaluation of maneuverability and visibility was assessed by each surgeon at the end of every procedure. Results: Kidney access into the Renal unit 1 was not possible without UAS for all ureteroscopes because of noncompliant ureter at the level of sacroiliac joint. The reusable digital ureteroscope was unable to reach one calix of the lower pole and one calix of the upper pole (Renal units 2 and 3) without UAS placement. Lower pole access with baskets and laser fibers was possible for each ureteroscope after UAS placement. No statistically significant differences were detected in angle deflection between ureteroscopes. The digital ureteroscope was preferred for visibility in all procedures: LithoVue for maneuverability in six procedures, fiber optic in five procedures, and the digital ureteroscope in one procedure. Conclusions: LithoVue seems to be comparable with conventional ureteroscopes in terms of visibility and manipulation into the collecting system in fresh human cadavers. Further studies in humans are needed to determine the clinical value of this new instrument. |
format | Online Article Text |
id | pubmed-4913498 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Mary Ann Liebert, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-49134982016-07-06 Comparison of New Single-Use Digital Flexible Ureteroscope Versus Nondisposable Fiber Optic and Digital Ureteroscope in a Cadaveric Model Proietti, Silvia Dragos, Laurian Molina, Wilson Doizi, Steeve Giusti, Guido Traxer, Olivier J Endourol Ureteroscopy and Percutaneous Procedures Purpose: To evaluate LithoVue, the new single-use digital flexible ureteroscope, in a human cadaveric model and compare it with a nondisposable fiber optic and digital flexible ureteroscopes. Materials and Methods: LithoVue, a conventional fiber optic, and digital flexible ureteroscopes were each tested in four renal units of recently deceased female cadavers by three surgeons. The following parameters were analyzed: accessibility to the kidney and navigation of the entire collecting system with and without ureteral access sheath (UAS), lower pole access measuring the deflection of the ureteroscope with the working channel empty, and with inside two different baskets and laser fibers. A subjective evaluation of maneuverability and visibility was assessed by each surgeon at the end of every procedure. Results: Kidney access into the Renal unit 1 was not possible without UAS for all ureteroscopes because of noncompliant ureter at the level of sacroiliac joint. The reusable digital ureteroscope was unable to reach one calix of the lower pole and one calix of the upper pole (Renal units 2 and 3) without UAS placement. Lower pole access with baskets and laser fibers was possible for each ureteroscope after UAS placement. No statistically significant differences were detected in angle deflection between ureteroscopes. The digital ureteroscope was preferred for visibility in all procedures: LithoVue for maneuverability in six procedures, fiber optic in five procedures, and the digital ureteroscope in one procedure. Conclusions: LithoVue seems to be comparable with conventional ureteroscopes in terms of visibility and manipulation into the collecting system in fresh human cadavers. Further studies in humans are needed to determine the clinical value of this new instrument. Mary Ann Liebert, Inc. 2016-06-01 /pmc/articles/PMC4913498/ /pubmed/27084572 http://dx.doi.org/10.1089/end.2016.0051 Text en © Silvia Proietti et al. 2016; Published by Mary Ann Liebert, Inc. This Open Access article is distributed under the terms of the Creative Commons Attribution Noncommercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Ureteroscopy and Percutaneous Procedures Proietti, Silvia Dragos, Laurian Molina, Wilson Doizi, Steeve Giusti, Guido Traxer, Olivier Comparison of New Single-Use Digital Flexible Ureteroscope Versus Nondisposable Fiber Optic and Digital Ureteroscope in a Cadaveric Model |
title | Comparison of New Single-Use Digital Flexible Ureteroscope Versus Nondisposable Fiber Optic and Digital Ureteroscope in a Cadaveric Model |
title_full | Comparison of New Single-Use Digital Flexible Ureteroscope Versus Nondisposable Fiber Optic and Digital Ureteroscope in a Cadaveric Model |
title_fullStr | Comparison of New Single-Use Digital Flexible Ureteroscope Versus Nondisposable Fiber Optic and Digital Ureteroscope in a Cadaveric Model |
title_full_unstemmed | Comparison of New Single-Use Digital Flexible Ureteroscope Versus Nondisposable Fiber Optic and Digital Ureteroscope in a Cadaveric Model |
title_short | Comparison of New Single-Use Digital Flexible Ureteroscope Versus Nondisposable Fiber Optic and Digital Ureteroscope in a Cadaveric Model |
title_sort | comparison of new single-use digital flexible ureteroscope versus nondisposable fiber optic and digital ureteroscope in a cadaveric model |
topic | Ureteroscopy and Percutaneous Procedures |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4913498/ https://www.ncbi.nlm.nih.gov/pubmed/27084572 http://dx.doi.org/10.1089/end.2016.0051 |
work_keys_str_mv | AT proiettisilvia comparisonofnewsingleusedigitalflexibleureteroscopeversusnondisposablefiberopticanddigitalureteroscopeinacadavericmodel AT dragoslaurian comparisonofnewsingleusedigitalflexibleureteroscopeversusnondisposablefiberopticanddigitalureteroscopeinacadavericmodel AT molinawilson comparisonofnewsingleusedigitalflexibleureteroscopeversusnondisposablefiberopticanddigitalureteroscopeinacadavericmodel AT doizisteeve comparisonofnewsingleusedigitalflexibleureteroscopeversusnondisposablefiberopticanddigitalureteroscopeinacadavericmodel AT giustiguido comparisonofnewsingleusedigitalflexibleureteroscopeversusnondisposablefiberopticanddigitalureteroscopeinacadavericmodel AT traxerolivier comparisonofnewsingleusedigitalflexibleureteroscopeversusnondisposablefiberopticanddigitalureteroscopeinacadavericmodel |