Cargando…
Echocardiographic Assessment of Cardiac Function by Conventional and Speckle‐Tracking Echocardiography in Dogs with Patent Ductus Arteriosus
BACKGROUND: Patent ductus arteriosus (PDA) is one of the most common congenital heart defects in dogs. Advanced echocardiographic techniques such as speckle‐tracking echocardiography (STE) have not been extensively used to evaluate cardiac function in affected dogs. HYPOTHESIS: Advanced echocardiogr...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4913585/ https://www.ncbi.nlm.nih.gov/pubmed/27177624 http://dx.doi.org/10.1111/jvim.13938 |
_version_ | 1782438424033099776 |
---|---|
author | Spalla, I. Locatelli, C. Zanaboni, A.M. Brambilla, P. Bussadori, C. |
author_facet | Spalla, I. Locatelli, C. Zanaboni, A.M. Brambilla, P. Bussadori, C. |
author_sort | Spalla, I. |
collection | PubMed |
description | BACKGROUND: Patent ductus arteriosus (PDA) is one of the most common congenital heart defects in dogs. Advanced echocardiographic techniques such as speckle‐tracking echocardiography (STE) have not been extensively used to evaluate cardiac function in affected dogs. HYPOTHESIS: Advanced echocardiographic techniques are more sensitive than standard echocardiographic techniques in analyzing systolic function in dogs with PDA. ANIMALS: Forty‐four client‐owned dogs: 34 dogs with PDA (preoperative evaluation) and 10 healthy sex‐ and weight‐matched controls. METHODS: Prospective study. Dogs were recruited over a 2‐year period. Complete echocardiographic evaluation was performed, including conventional (end‐diastolic volumes indexed to body surface area in B and M‐mode [EDVI(B) (/M)], end‐systolic volumes indexed to body surface area in B and M‐mode [ESVI(B) (/M)], allometric scaling in diastole and systole [AlloD/S], pulmonary flow to systemic flow [Qp/Qs], ejection fraction [EF] and fractional shortening [FS]) and speckle‐tracking echocardiography ([STE]: global longitudinal, radial and circumferential strain [S] and strain rate [SR]). RESULTS: Dogs with PDA had significantly different EDVI(B) (/M), ESVI(B) (/M), AlloD/S, Qp/Qs and all STE‐derived parameters (global longitudinal S and SR, global circumferential S and SR, global radial S and SR)compared to healthy dogs. No correlation was found between standard techniques (EDVI(B) (/M), ESVI(B) (/M), AlloD/S, Qp/Qs) and STE‐derived parameters (global longitudinal, circumferential and radial S and SR). CONCLUSION AND CLINICAL IMPORTANCE: Conventional parameters routinely used to assess systolic function (EF and FS) were not different between the groups; STE‐derived parameters identified subtle changes in cardiac systolic function and contractility between the 2 groups of dogs. Based on these findings, STE may be a more appropriate tool to assess cardiac contractility in dogs with PDA. |
format | Online Article Text |
id | pubmed-4913585 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-49135852016-06-22 Echocardiographic Assessment of Cardiac Function by Conventional and Speckle‐Tracking Echocardiography in Dogs with Patent Ductus Arteriosus Spalla, I. Locatelli, C. Zanaboni, A.M. Brambilla, P. Bussadori, C. J Vet Intern Med SMALL ANIMAL BACKGROUND: Patent ductus arteriosus (PDA) is one of the most common congenital heart defects in dogs. Advanced echocardiographic techniques such as speckle‐tracking echocardiography (STE) have not been extensively used to evaluate cardiac function in affected dogs. HYPOTHESIS: Advanced echocardiographic techniques are more sensitive than standard echocardiographic techniques in analyzing systolic function in dogs with PDA. ANIMALS: Forty‐four client‐owned dogs: 34 dogs with PDA (preoperative evaluation) and 10 healthy sex‐ and weight‐matched controls. METHODS: Prospective study. Dogs were recruited over a 2‐year period. Complete echocardiographic evaluation was performed, including conventional (end‐diastolic volumes indexed to body surface area in B and M‐mode [EDVI(B) (/M)], end‐systolic volumes indexed to body surface area in B and M‐mode [ESVI(B) (/M)], allometric scaling in diastole and systole [AlloD/S], pulmonary flow to systemic flow [Qp/Qs], ejection fraction [EF] and fractional shortening [FS]) and speckle‐tracking echocardiography ([STE]: global longitudinal, radial and circumferential strain [S] and strain rate [SR]). RESULTS: Dogs with PDA had significantly different EDVI(B) (/M), ESVI(B) (/M), AlloD/S, Qp/Qs and all STE‐derived parameters (global longitudinal S and SR, global circumferential S and SR, global radial S and SR)compared to healthy dogs. No correlation was found between standard techniques (EDVI(B) (/M), ESVI(B) (/M), AlloD/S, Qp/Qs) and STE‐derived parameters (global longitudinal, circumferential and radial S and SR). CONCLUSION AND CLINICAL IMPORTANCE: Conventional parameters routinely used to assess systolic function (EF and FS) were not different between the groups; STE‐derived parameters identified subtle changes in cardiac systolic function and contractility between the 2 groups of dogs. Based on these findings, STE may be a more appropriate tool to assess cardiac contractility in dogs with PDA. John Wiley and Sons Inc. 2016-05-14 2016 /pmc/articles/PMC4913585/ /pubmed/27177624 http://dx.doi.org/10.1111/jvim.13938 Text en Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial (http://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | SMALL ANIMAL Spalla, I. Locatelli, C. Zanaboni, A.M. Brambilla, P. Bussadori, C. Echocardiographic Assessment of Cardiac Function by Conventional and Speckle‐Tracking Echocardiography in Dogs with Patent Ductus Arteriosus |
title | Echocardiographic Assessment of Cardiac Function by Conventional and Speckle‐Tracking Echocardiography in Dogs with Patent Ductus Arteriosus |
title_full | Echocardiographic Assessment of Cardiac Function by Conventional and Speckle‐Tracking Echocardiography in Dogs with Patent Ductus Arteriosus |
title_fullStr | Echocardiographic Assessment of Cardiac Function by Conventional and Speckle‐Tracking Echocardiography in Dogs with Patent Ductus Arteriosus |
title_full_unstemmed | Echocardiographic Assessment of Cardiac Function by Conventional and Speckle‐Tracking Echocardiography in Dogs with Patent Ductus Arteriosus |
title_short | Echocardiographic Assessment of Cardiac Function by Conventional and Speckle‐Tracking Echocardiography in Dogs with Patent Ductus Arteriosus |
title_sort | echocardiographic assessment of cardiac function by conventional and speckle‐tracking echocardiography in dogs with patent ductus arteriosus |
topic | SMALL ANIMAL |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4913585/ https://www.ncbi.nlm.nih.gov/pubmed/27177624 http://dx.doi.org/10.1111/jvim.13938 |
work_keys_str_mv | AT spallai echocardiographicassessmentofcardiacfunctionbyconventionalandspeckletrackingechocardiographyindogswithpatentductusarteriosus AT locatellic echocardiographicassessmentofcardiacfunctionbyconventionalandspeckletrackingechocardiographyindogswithpatentductusarteriosus AT zanaboniam echocardiographicassessmentofcardiacfunctionbyconventionalandspeckletrackingechocardiographyindogswithpatentductusarteriosus AT brambillap echocardiographicassessmentofcardiacfunctionbyconventionalandspeckletrackingechocardiographyindogswithpatentductusarteriosus AT bussadoric echocardiographicassessmentofcardiacfunctionbyconventionalandspeckletrackingechocardiographyindogswithpatentductusarteriosus |