Cargando…

Probe-Position Error Correction in Planar Near Field Measurements at 60 GHz: Experimental Verification

This study was conducted to verify that the probe-position error correction can be successfully applied to real data obtained on a planar near-field range where probe position errors are known. Since probe position-error correction is most important at high frequencies, measurements were made at 60...

Descripción completa

Detalles Bibliográficos
Autor principal: Muth, Lorant A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1992
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4914235/
https://www.ncbi.nlm.nih.gov/pubmed/28053433
http://dx.doi.org/10.6028/jres.097.009
_version_ 1782438522492289024
author Muth, Lorant A.
author_facet Muth, Lorant A.
author_sort Muth, Lorant A.
collection PubMed
description This study was conducted to verify that the probe-position error correction can be successfully applied to real data obtained on a planar near-field range where probe position errors are known. Since probe position-error correction is most important at high frequencies, measurements were made at 60 GHz. Six planar scans at z positions separated by 0.03 A were obtained. The correction technique was applied to an error-contaminated near field constructed out of the six scans according to a discretized periodic error function. The results indicate that probe position errors can be removed from real near-field data as successfully as from simulated data; some residual errors, which are thought to be due to multiple reflections, residual drift in the measurement system, and residual probe position errors in all three coordinates, are observed.
format Online
Article
Text
id pubmed-4914235
institution National Center for Biotechnology Information
language English
publishDate 1992
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-49142352017-01-04 Probe-Position Error Correction in Planar Near Field Measurements at 60 GHz: Experimental Verification Muth, Lorant A. J Res Natl Inst Stand Technol Article This study was conducted to verify that the probe-position error correction can be successfully applied to real data obtained on a planar near-field range where probe position errors are known. Since probe position-error correction is most important at high frequencies, measurements were made at 60 GHz. Six planar scans at z positions separated by 0.03 A were obtained. The correction technique was applied to an error-contaminated near field constructed out of the six scans according to a discretized periodic error function. The results indicate that probe position errors can be removed from real near-field data as successfully as from simulated data; some residual errors, which are thought to be due to multiple reflections, residual drift in the measurement system, and residual probe position errors in all three coordinates, are observed. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1992 /pmc/articles/PMC4914235/ /pubmed/28053433 http://dx.doi.org/10.6028/jres.097.009 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Muth, Lorant A.
Probe-Position Error Correction in Planar Near Field Measurements at 60 GHz: Experimental Verification
title Probe-Position Error Correction in Planar Near Field Measurements at 60 GHz: Experimental Verification
title_full Probe-Position Error Correction in Planar Near Field Measurements at 60 GHz: Experimental Verification
title_fullStr Probe-Position Error Correction in Planar Near Field Measurements at 60 GHz: Experimental Verification
title_full_unstemmed Probe-Position Error Correction in Planar Near Field Measurements at 60 GHz: Experimental Verification
title_short Probe-Position Error Correction in Planar Near Field Measurements at 60 GHz: Experimental Verification
title_sort probe-position error correction in planar near field measurements at 60 ghz: experimental verification
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4914235/
https://www.ncbi.nlm.nih.gov/pubmed/28053433
http://dx.doi.org/10.6028/jres.097.009
work_keys_str_mv AT muthloranta probepositionerrorcorrectioninplanarnearfieldmeasurementsat60ghzexperimentalverification