Cargando…
Probe-Position Error Correction in Planar Near Field Measurements at 60 GHz: Experimental Verification
This study was conducted to verify that the probe-position error correction can be successfully applied to real data obtained on a planar near-field range where probe position errors are known. Since probe position-error correction is most important at high frequencies, measurements were made at 60...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
1992
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4914235/ https://www.ncbi.nlm.nih.gov/pubmed/28053433 http://dx.doi.org/10.6028/jres.097.009 |
_version_ | 1782438522492289024 |
---|---|
author | Muth, Lorant A. |
author_facet | Muth, Lorant A. |
author_sort | Muth, Lorant A. |
collection | PubMed |
description | This study was conducted to verify that the probe-position error correction can be successfully applied to real data obtained on a planar near-field range where probe position errors are known. Since probe position-error correction is most important at high frequencies, measurements were made at 60 GHz. Six planar scans at z positions separated by 0.03 A were obtained. The correction technique was applied to an error-contaminated near field constructed out of the six scans according to a discretized periodic error function. The results indicate that probe position errors can be removed from real near-field data as successfully as from simulated data; some residual errors, which are thought to be due to multiple reflections, residual drift in the measurement system, and residual probe position errors in all three coordinates, are observed. |
format | Online Article Text |
id | pubmed-4914235 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1992 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-49142352017-01-04 Probe-Position Error Correction in Planar Near Field Measurements at 60 GHz: Experimental Verification Muth, Lorant A. J Res Natl Inst Stand Technol Article This study was conducted to verify that the probe-position error correction can be successfully applied to real data obtained on a planar near-field range where probe position errors are known. Since probe position-error correction is most important at high frequencies, measurements were made at 60 GHz. Six planar scans at z positions separated by 0.03 A were obtained. The correction technique was applied to an error-contaminated near field constructed out of the six scans according to a discretized periodic error function. The results indicate that probe position errors can be removed from real near-field data as successfully as from simulated data; some residual errors, which are thought to be due to multiple reflections, residual drift in the measurement system, and residual probe position errors in all three coordinates, are observed. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1992 /pmc/articles/PMC4914235/ /pubmed/28053433 http://dx.doi.org/10.6028/jres.097.009 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Muth, Lorant A. Probe-Position Error Correction in Planar Near Field Measurements at 60 GHz: Experimental Verification |
title | Probe-Position Error Correction in Planar Near Field Measurements at 60 GHz: Experimental Verification |
title_full | Probe-Position Error Correction in Planar Near Field Measurements at 60 GHz: Experimental Verification |
title_fullStr | Probe-Position Error Correction in Planar Near Field Measurements at 60 GHz: Experimental Verification |
title_full_unstemmed | Probe-Position Error Correction in Planar Near Field Measurements at 60 GHz: Experimental Verification |
title_short | Probe-Position Error Correction in Planar Near Field Measurements at 60 GHz: Experimental Verification |
title_sort | probe-position error correction in planar near field measurements at 60 ghz: experimental verification |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4914235/ https://www.ncbi.nlm.nih.gov/pubmed/28053433 http://dx.doi.org/10.6028/jres.097.009 |
work_keys_str_mv | AT muthloranta probepositionerrorcorrectioninplanarnearfieldmeasurementsat60ghzexperimentalverification |