Cargando…

Evaluation of Serum Volume Losses During Long-Term Storage

Aliquots of serum collected in a large case-control study of cervical cancer were stored at −70°C for up to 4 years during implementation of the study. When 500 μL serum aliquots were thawed in preparation for carotenoid and vitamin A assays, volumes were noticeably variable and fell below 500 μL in...

Descripción completa

Detalles Bibliográficos
Autores principales: Craft, Neal E., Epler, Katherine S., Butler, Therese A., May, Willie E., Ziegler, Regina G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1993
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4914240/
https://www.ncbi.nlm.nih.gov/pubmed/28053478
http://dx.doi.org/10.6028/jres.098.027
_version_ 1782438523649916928
author Craft, Neal E.
Epler, Katherine S.
Butler, Therese A.
May, Willie E.
Ziegler, Regina G.
author_facet Craft, Neal E.
Epler, Katherine S.
Butler, Therese A.
May, Willie E.
Ziegler, Regina G.
author_sort Craft, Neal E.
collection PubMed
description Aliquots of serum collected in a large case-control study of cervical cancer were stored at −70°C for up to 4 years during implementation of the study. When 500 μL serum aliquots were thawed in preparation for carotenoid and vitamin A assays, volumes were noticeably variable and fell below 500 μL in the majority of the samples. We were concerned about evaporation/sublimation during storage of the samples because loss of water would concentrate the analytes of interest. We evaluated the use of density and sodium ion concentration measurements to confirm its occurrence. We found that serum density was an unreliable indicator of extent of volume loss since the anticipated increases in density due to evaporation were of the same magnitude as inter-individual variation in serum density. In contrast, Na(+) concentration is tightly regulated and would rise if water had been lost from the samples. In a representative sample of serum aliquots from the case-control study, 24 of 25 vials contained less than 500 μL of serum. The mean sodium ion concentration (138.1 ± 3.6 mmol/L) was within the normal range for human serum of 136–145 mmol/L, and no correlation was observed between serum volume and Na(+) concentration. These results strongly suggest that the observed low volumes were not due to evaporative losses. Instead, the variably low volumes of serum aliquots were probably due to pipetting errors in the initial aliquotting resulting from the use of air-displacement pipettes.
format Online
Article
Text
id pubmed-4914240
institution National Center for Biotechnology Information
language English
publishDate 1993
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-49142402017-01-04 Evaluation of Serum Volume Losses During Long-Term Storage Craft, Neal E. Epler, Katherine S. Butler, Therese A. May, Willie E. Ziegler, Regina G. J Res Natl Inst Stand Technol Article Aliquots of serum collected in a large case-control study of cervical cancer were stored at −70°C for up to 4 years during implementation of the study. When 500 μL serum aliquots were thawed in preparation for carotenoid and vitamin A assays, volumes were noticeably variable and fell below 500 μL in the majority of the samples. We were concerned about evaporation/sublimation during storage of the samples because loss of water would concentrate the analytes of interest. We evaluated the use of density and sodium ion concentration measurements to confirm its occurrence. We found that serum density was an unreliable indicator of extent of volume loss since the anticipated increases in density due to evaporation were of the same magnitude as inter-individual variation in serum density. In contrast, Na(+) concentration is tightly regulated and would rise if water had been lost from the samples. In a representative sample of serum aliquots from the case-control study, 24 of 25 vials contained less than 500 μL of serum. The mean sodium ion concentration (138.1 ± 3.6 mmol/L) was within the normal range for human serum of 136–145 mmol/L, and no correlation was observed between serum volume and Na(+) concentration. These results strongly suggest that the observed low volumes were not due to evaporative losses. Instead, the variably low volumes of serum aliquots were probably due to pipetting errors in the initial aliquotting resulting from the use of air-displacement pipettes. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1993 /pmc/articles/PMC4914240/ /pubmed/28053478 http://dx.doi.org/10.6028/jres.098.027 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Craft, Neal E.
Epler, Katherine S.
Butler, Therese A.
May, Willie E.
Ziegler, Regina G.
Evaluation of Serum Volume Losses During Long-Term Storage
title Evaluation of Serum Volume Losses During Long-Term Storage
title_full Evaluation of Serum Volume Losses During Long-Term Storage
title_fullStr Evaluation of Serum Volume Losses During Long-Term Storage
title_full_unstemmed Evaluation of Serum Volume Losses During Long-Term Storage
title_short Evaluation of Serum Volume Losses During Long-Term Storage
title_sort evaluation of serum volume losses during long-term storage
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4914240/
https://www.ncbi.nlm.nih.gov/pubmed/28053478
http://dx.doi.org/10.6028/jres.098.027
work_keys_str_mv AT craftneale evaluationofserumvolumelossesduringlongtermstorage
AT eplerkatherines evaluationofserumvolumelossesduringlongtermstorage
AT butlertheresea evaluationofserumvolumelossesduringlongtermstorage
AT maywilliee evaluationofserumvolumelossesduringlongtermstorage
AT zieglerreginag evaluationofserumvolumelossesduringlongtermstorage