Cargando…
Application of Optical Coherence Tomography and Contrast Sensitivity Test for Observing Fundus Changes of Patients With Pregnancy-Induced Hypertension Syndrome
This study was aimed to investigate the fundus changes of patients with pregnancy-induced hypertension syndrome (PIHS) using optical coherence tomography (OCT) technology and contrast sensitivity (CS) tests. Ninety-eight patients with PIHS underwent routine eye examinations including vision correcti...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4915865/ https://www.ncbi.nlm.nih.gov/pubmed/26554764 http://dx.doi.org/10.1097/MD.0000000000001641 |
_version_ | 1782438745352437760 |
---|---|
author | Wang, Zhixue Zou, Yuanyuan Li, Wenying Wang, Xueyan Zhang, Min Wang, Wenying |
author_facet | Wang, Zhixue Zou, Yuanyuan Li, Wenying Wang, Xueyan Zhang, Min Wang, Wenying |
author_sort | Wang, Zhixue |
collection | PubMed |
description | This study was aimed to investigate the fundus changes of patients with pregnancy-induced hypertension syndrome (PIHS) using optical coherence tomography (OCT) technology and contrast sensitivity (CS) tests. Ninety-eight patients with PIHS underwent routine eye examinations including vision correction, fundus examination, OCT, and CS tests. The CS test was performed at low, medium, and high frequency, respectively. Moreover, the difference in CS tests between 2 groups was analyzed by independent-samples T test. The Kruskal–Wallis rank sum test and linear regression model were used to detect the correlation of OCT with CS, respectively. Meanwhile Satterthwaite approximate T test was adopted for pairwise comparisons after nonparametric analysis of variance. The OCT test revealed that 56.76% of the examined eyes showed shallow retinal detachment in the macula lutea and around the optic disk. The differences in CS at each spatial frequency between the case and control group were statistically significant (P < 0.01). Besides, OCT manifestations were associated with CS at each spacial frequency including 1.5, 3, 6, 12, and 18 frequency (P < 0.01). And patients with abnormal manifestations of OCT showed lower CS at each spacial frequency than those without abnormal OCT manifestations. What's more the OCT manifestation 1 showed the greatest impact on CS at each spacial frequency. The results showed that abnormal OCT manifestations were correlated with CS in PIHS. OCT and CS tests might be valuable methods in observing fundus changes for PIHS patients. |
format | Online Article Text |
id | pubmed-4915865 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-49158652016-07-05 Application of Optical Coherence Tomography and Contrast Sensitivity Test for Observing Fundus Changes of Patients With Pregnancy-Induced Hypertension Syndrome Wang, Zhixue Zou, Yuanyuan Li, Wenying Wang, Xueyan Zhang, Min Wang, Wenying Medicine (Baltimore) 7400 This study was aimed to investigate the fundus changes of patients with pregnancy-induced hypertension syndrome (PIHS) using optical coherence tomography (OCT) technology and contrast sensitivity (CS) tests. Ninety-eight patients with PIHS underwent routine eye examinations including vision correction, fundus examination, OCT, and CS tests. The CS test was performed at low, medium, and high frequency, respectively. Moreover, the difference in CS tests between 2 groups was analyzed by independent-samples T test. The Kruskal–Wallis rank sum test and linear regression model were used to detect the correlation of OCT with CS, respectively. Meanwhile Satterthwaite approximate T test was adopted for pairwise comparisons after nonparametric analysis of variance. The OCT test revealed that 56.76% of the examined eyes showed shallow retinal detachment in the macula lutea and around the optic disk. The differences in CS at each spatial frequency between the case and control group were statistically significant (P < 0.01). Besides, OCT manifestations were associated with CS at each spacial frequency including 1.5, 3, 6, 12, and 18 frequency (P < 0.01). And patients with abnormal manifestations of OCT showed lower CS at each spacial frequency than those without abnormal OCT manifestations. What's more the OCT manifestation 1 showed the greatest impact on CS at each spacial frequency. The results showed that abnormal OCT manifestations were correlated with CS in PIHS. OCT and CS tests might be valuable methods in observing fundus changes for PIHS patients. Wolters Kluwer Health 2015-11-06 /pmc/articles/PMC4915865/ /pubmed/26554764 http://dx.doi.org/10.1097/MD.0000000000001641 Text en Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0 |
spellingShingle | 7400 Wang, Zhixue Zou, Yuanyuan Li, Wenying Wang, Xueyan Zhang, Min Wang, Wenying Application of Optical Coherence Tomography and Contrast Sensitivity Test for Observing Fundus Changes of Patients With Pregnancy-Induced Hypertension Syndrome |
title | Application of Optical Coherence Tomography and Contrast Sensitivity Test for Observing Fundus Changes of Patients With Pregnancy-Induced Hypertension Syndrome |
title_full | Application of Optical Coherence Tomography and Contrast Sensitivity Test for Observing Fundus Changes of Patients With Pregnancy-Induced Hypertension Syndrome |
title_fullStr | Application of Optical Coherence Tomography and Contrast Sensitivity Test for Observing Fundus Changes of Patients With Pregnancy-Induced Hypertension Syndrome |
title_full_unstemmed | Application of Optical Coherence Tomography and Contrast Sensitivity Test for Observing Fundus Changes of Patients With Pregnancy-Induced Hypertension Syndrome |
title_short | Application of Optical Coherence Tomography and Contrast Sensitivity Test for Observing Fundus Changes of Patients With Pregnancy-Induced Hypertension Syndrome |
title_sort | application of optical coherence tomography and contrast sensitivity test for observing fundus changes of patients with pregnancy-induced hypertension syndrome |
topic | 7400 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4915865/ https://www.ncbi.nlm.nih.gov/pubmed/26554764 http://dx.doi.org/10.1097/MD.0000000000001641 |
work_keys_str_mv | AT wangzhixue applicationofopticalcoherencetomographyandcontrastsensitivitytestforobservingfunduschangesofpatientswithpregnancyinducedhypertensionsyndrome AT zouyuanyuan applicationofopticalcoherencetomographyandcontrastsensitivitytestforobservingfunduschangesofpatientswithpregnancyinducedhypertensionsyndrome AT liwenying applicationofopticalcoherencetomographyandcontrastsensitivitytestforobservingfunduschangesofpatientswithpregnancyinducedhypertensionsyndrome AT wangxueyan applicationofopticalcoherencetomographyandcontrastsensitivitytestforobservingfunduschangesofpatientswithpregnancyinducedhypertensionsyndrome AT zhangmin applicationofopticalcoherencetomographyandcontrastsensitivitytestforobservingfunduschangesofpatientswithpregnancyinducedhypertensionsyndrome AT wangwenying applicationofopticalcoherencetomographyandcontrastsensitivitytestforobservingfunduschangesofpatientswithpregnancyinducedhypertensionsyndrome |