Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants

Background. In premature infants, maintaining blood partial pressure of carbon dioxide (pCO(2)) value within a narrow range is important to avoid cerebral lesions. The aim of this study was to assess the accuracy of a noninvasive transcutaneous method (TcpCO(2)), compared to blood partial pressure o...

Descripción completa

Detalles Bibliográficos
Autores principales: Janaillac, Marie, Labarinas, Sonia, Pfister, Riccardo E., Karam, Oliver
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4916268/
https://www.ncbi.nlm.nih.gov/pubmed/27375901
http://dx.doi.org/10.1155/2016/8041967
_version_ 1782438800119562240
author Janaillac, Marie
Labarinas, Sonia
Pfister, Riccardo E.
Karam, Oliver
author_facet Janaillac, Marie
Labarinas, Sonia
Pfister, Riccardo E.
Karam, Oliver
author_sort Janaillac, Marie
collection PubMed
description Background. In premature infants, maintaining blood partial pressure of carbon dioxide (pCO(2)) value within a narrow range is important to avoid cerebral lesions. The aim of this study was to assess the accuracy of a noninvasive transcutaneous method (TcpCO(2)), compared to blood partial pressure of carbon dioxide (pCO(2)). Methods. Retrospective observational study in a tertiary neonatal intensive care unit. We analyzed the correlation between blood pCO(2) and transcutaneous values and the accuracy between the trends of blood pCO(2) and TcpCO(2) in all consecutive premature infants born at <33 weeks' gestational age. Results. 248 infants were included (median gestational age: 29 + 5 weeks and median birth weight: 1250 g), providing 1365 pairs of TcpCO(2) and blood pCO(2) values. Pearson's R correlation between these values was 0.58. The mean bias was −0.93 kPa with a 95% confidence limit of agreement of −4.05 to +2.16 kPa. Correlation between the trends of TcpCO(2) and blood pCO(2) values was good in only 39.6%. Conclusions. In premature infants, TcpCO(2) was poorly correlated to blood pCO(2), with a wide limit of agreement. Furthermore, concordance between trends was equally low. We warn about clinical decision-making on TcpCO(2) alone when used as continuous monitoring.
format Online
Article
Text
id pubmed-4916268
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-49162682016-07-03 Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants Janaillac, Marie Labarinas, Sonia Pfister, Riccardo E. Karam, Oliver Crit Care Res Pract Research Article Background. In premature infants, maintaining blood partial pressure of carbon dioxide (pCO(2)) value within a narrow range is important to avoid cerebral lesions. The aim of this study was to assess the accuracy of a noninvasive transcutaneous method (TcpCO(2)), compared to blood partial pressure of carbon dioxide (pCO(2)). Methods. Retrospective observational study in a tertiary neonatal intensive care unit. We analyzed the correlation between blood pCO(2) and transcutaneous values and the accuracy between the trends of blood pCO(2) and TcpCO(2) in all consecutive premature infants born at <33 weeks' gestational age. Results. 248 infants were included (median gestational age: 29 + 5 weeks and median birth weight: 1250 g), providing 1365 pairs of TcpCO(2) and blood pCO(2) values. Pearson's R correlation between these values was 0.58. The mean bias was −0.93 kPa with a 95% confidence limit of agreement of −4.05 to +2.16 kPa. Correlation between the trends of TcpCO(2) and blood pCO(2) values was good in only 39.6%. Conclusions. In premature infants, TcpCO(2) was poorly correlated to blood pCO(2), with a wide limit of agreement. Furthermore, concordance between trends was equally low. We warn about clinical decision-making on TcpCO(2) alone when used as continuous monitoring. Hindawi Publishing Corporation 2016 2016-06-08 /pmc/articles/PMC4916268/ /pubmed/27375901 http://dx.doi.org/10.1155/2016/8041967 Text en Copyright © 2016 Marie Janaillac et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Janaillac, Marie
Labarinas, Sonia
Pfister, Riccardo E.
Karam, Oliver
Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants
title Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants
title_full Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants
title_fullStr Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants
title_full_unstemmed Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants
title_short Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants
title_sort accuracy of transcutaneous carbon dioxide measurement in premature infants
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4916268/
https://www.ncbi.nlm.nih.gov/pubmed/27375901
http://dx.doi.org/10.1155/2016/8041967
work_keys_str_mv AT janaillacmarie accuracyoftranscutaneouscarbondioxidemeasurementinprematureinfants
AT labarinassonia accuracyoftranscutaneouscarbondioxidemeasurementinprematureinfants
AT pfisterriccardoe accuracyoftranscutaneouscarbondioxidemeasurementinprematureinfants
AT karamoliver accuracyoftranscutaneouscarbondioxidemeasurementinprematureinfants