Cargando…

Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation

Heart failure is a leading cause of death, yet its underlying electrophysiological (EP) mechanisms are not well understood. In this study, we use a multiscale approach to analyze a model of heart failure and connect its results to features of the electrocardiogram (ECG). The heart failure model is d...

Descripción completa

Detalles Bibliográficos
Autores principales: Ponnaluri, Aditya V. S., Perotti, Luigi E., Liu, Michael, Qu, Zhilin, Weiss, James N., Ennis, Daniel B., Klug, William S., Garfinkel, Alan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4919062/
https://www.ncbi.nlm.nih.gov/pubmed/27336310
http://dx.doi.org/10.1371/journal.pcbi.1004968
_version_ 1782439203110387712
author Ponnaluri, Aditya V. S.
Perotti, Luigi E.
Liu, Michael
Qu, Zhilin
Weiss, James N.
Ennis, Daniel B.
Klug, William S.
Garfinkel, Alan
author_facet Ponnaluri, Aditya V. S.
Perotti, Luigi E.
Liu, Michael
Qu, Zhilin
Weiss, James N.
Ennis, Daniel B.
Klug, William S.
Garfinkel, Alan
author_sort Ponnaluri, Aditya V. S.
collection PubMed
description Heart failure is a leading cause of death, yet its underlying electrophysiological (EP) mechanisms are not well understood. In this study, we use a multiscale approach to analyze a model of heart failure and connect its results to features of the electrocardiogram (ECG). The heart failure model is derived by modifying a previously validated electrophysiology model for a healthy rabbit heart. Specifically, in accordance with the heart failure literature, we modified the cell EP by changing both membrane currents and calcium handling. At the tissue level, we modeled the increased gap junction lateralization and lower conduction velocity due to downregulation of Connexin 43. At the biventricular level, we reduced the apex-to-base and transmural gradients of action potential duration (APD). The failing cell model was first validated by reproducing the longer action potential, slower and lower calcium transient, and earlier alternans characteristic of heart failure EP. Subsequently, we compared the electrical wave propagation in one dimensional cables of healthy and failing cells. The validated cell model was then used to simulate the EP of heart failure in an anatomically accurate biventricular rabbit model. As pacing cycle length decreases, both the normal and failing heart develop T-wave alternans, but only the failing heart shows QRS alternans (although moderate) at rapid pacing. Moreover, T-wave alternans is significantly more pronounced in the failing heart. At rapid pacing, APD maps show areas of conduction block in the failing heart. Finally, accelerated pacing initiated wave reentry and breakup in the failing heart. Further, the onset of VF was not observed with an upregulation of SERCA, a potential drug therapy, using the same protocol. The changes introduced at the cell and tissue level have increased the failing heart’s susceptibility to dynamic instabilities and arrhythmias under rapid pacing. However, the observed increase in arrhythmogenic potential is not due to a steepening of the restitution curve (not present in our model), but rather to a novel blocking mechanism.
format Online
Article
Text
id pubmed-4919062
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-49190622016-07-08 Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation Ponnaluri, Aditya V. S. Perotti, Luigi E. Liu, Michael Qu, Zhilin Weiss, James N. Ennis, Daniel B. Klug, William S. Garfinkel, Alan PLoS Comput Biol Research Article Heart failure is a leading cause of death, yet its underlying electrophysiological (EP) mechanisms are not well understood. In this study, we use a multiscale approach to analyze a model of heart failure and connect its results to features of the electrocardiogram (ECG). The heart failure model is derived by modifying a previously validated electrophysiology model for a healthy rabbit heart. Specifically, in accordance with the heart failure literature, we modified the cell EP by changing both membrane currents and calcium handling. At the tissue level, we modeled the increased gap junction lateralization and lower conduction velocity due to downregulation of Connexin 43. At the biventricular level, we reduced the apex-to-base and transmural gradients of action potential duration (APD). The failing cell model was first validated by reproducing the longer action potential, slower and lower calcium transient, and earlier alternans characteristic of heart failure EP. Subsequently, we compared the electrical wave propagation in one dimensional cables of healthy and failing cells. The validated cell model was then used to simulate the EP of heart failure in an anatomically accurate biventricular rabbit model. As pacing cycle length decreases, both the normal and failing heart develop T-wave alternans, but only the failing heart shows QRS alternans (although moderate) at rapid pacing. Moreover, T-wave alternans is significantly more pronounced in the failing heart. At rapid pacing, APD maps show areas of conduction block in the failing heart. Finally, accelerated pacing initiated wave reentry and breakup in the failing heart. Further, the onset of VF was not observed with an upregulation of SERCA, a potential drug therapy, using the same protocol. The changes introduced at the cell and tissue level have increased the failing heart’s susceptibility to dynamic instabilities and arrhythmias under rapid pacing. However, the observed increase in arrhythmogenic potential is not due to a steepening of the restitution curve (not present in our model), but rather to a novel blocking mechanism. Public Library of Science 2016-06-23 /pmc/articles/PMC4919062/ /pubmed/27336310 http://dx.doi.org/10.1371/journal.pcbi.1004968 Text en © 2016 Ponnaluri et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Ponnaluri, Aditya V. S.
Perotti, Luigi E.
Liu, Michael
Qu, Zhilin
Weiss, James N.
Ennis, Daniel B.
Klug, William S.
Garfinkel, Alan
Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation
title Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation
title_full Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation
title_fullStr Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation
title_full_unstemmed Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation
title_short Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation
title_sort electrophysiology of heart failure using a rabbit model: from the failing myocyte to ventricular fibrillation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4919062/
https://www.ncbi.nlm.nih.gov/pubmed/27336310
http://dx.doi.org/10.1371/journal.pcbi.1004968
work_keys_str_mv AT ponnaluriadityavs electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation
AT perottiluigie electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation
AT liumichael electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation
AT quzhilin electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation
AT weissjamesn electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation
AT ennisdanielb electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation
AT klugwilliams electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation
AT garfinkelalan electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation