Cargando…
Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation
Heart failure is a leading cause of death, yet its underlying electrophysiological (EP) mechanisms are not well understood. In this study, we use a multiscale approach to analyze a model of heart failure and connect its results to features of the electrocardiogram (ECG). The heart failure model is d...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4919062/ https://www.ncbi.nlm.nih.gov/pubmed/27336310 http://dx.doi.org/10.1371/journal.pcbi.1004968 |
_version_ | 1782439203110387712 |
---|---|
author | Ponnaluri, Aditya V. S. Perotti, Luigi E. Liu, Michael Qu, Zhilin Weiss, James N. Ennis, Daniel B. Klug, William S. Garfinkel, Alan |
author_facet | Ponnaluri, Aditya V. S. Perotti, Luigi E. Liu, Michael Qu, Zhilin Weiss, James N. Ennis, Daniel B. Klug, William S. Garfinkel, Alan |
author_sort | Ponnaluri, Aditya V. S. |
collection | PubMed |
description | Heart failure is a leading cause of death, yet its underlying electrophysiological (EP) mechanisms are not well understood. In this study, we use a multiscale approach to analyze a model of heart failure and connect its results to features of the electrocardiogram (ECG). The heart failure model is derived by modifying a previously validated electrophysiology model for a healthy rabbit heart. Specifically, in accordance with the heart failure literature, we modified the cell EP by changing both membrane currents and calcium handling. At the tissue level, we modeled the increased gap junction lateralization and lower conduction velocity due to downregulation of Connexin 43. At the biventricular level, we reduced the apex-to-base and transmural gradients of action potential duration (APD). The failing cell model was first validated by reproducing the longer action potential, slower and lower calcium transient, and earlier alternans characteristic of heart failure EP. Subsequently, we compared the electrical wave propagation in one dimensional cables of healthy and failing cells. The validated cell model was then used to simulate the EP of heart failure in an anatomically accurate biventricular rabbit model. As pacing cycle length decreases, both the normal and failing heart develop T-wave alternans, but only the failing heart shows QRS alternans (although moderate) at rapid pacing. Moreover, T-wave alternans is significantly more pronounced in the failing heart. At rapid pacing, APD maps show areas of conduction block in the failing heart. Finally, accelerated pacing initiated wave reentry and breakup in the failing heart. Further, the onset of VF was not observed with an upregulation of SERCA, a potential drug therapy, using the same protocol. The changes introduced at the cell and tissue level have increased the failing heart’s susceptibility to dynamic instabilities and arrhythmias under rapid pacing. However, the observed increase in arrhythmogenic potential is not due to a steepening of the restitution curve (not present in our model), but rather to a novel blocking mechanism. |
format | Online Article Text |
id | pubmed-4919062 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-49190622016-07-08 Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation Ponnaluri, Aditya V. S. Perotti, Luigi E. Liu, Michael Qu, Zhilin Weiss, James N. Ennis, Daniel B. Klug, William S. Garfinkel, Alan PLoS Comput Biol Research Article Heart failure is a leading cause of death, yet its underlying electrophysiological (EP) mechanisms are not well understood. In this study, we use a multiscale approach to analyze a model of heart failure and connect its results to features of the electrocardiogram (ECG). The heart failure model is derived by modifying a previously validated electrophysiology model for a healthy rabbit heart. Specifically, in accordance with the heart failure literature, we modified the cell EP by changing both membrane currents and calcium handling. At the tissue level, we modeled the increased gap junction lateralization and lower conduction velocity due to downregulation of Connexin 43. At the biventricular level, we reduced the apex-to-base and transmural gradients of action potential duration (APD). The failing cell model was first validated by reproducing the longer action potential, slower and lower calcium transient, and earlier alternans characteristic of heart failure EP. Subsequently, we compared the electrical wave propagation in one dimensional cables of healthy and failing cells. The validated cell model was then used to simulate the EP of heart failure in an anatomically accurate biventricular rabbit model. As pacing cycle length decreases, both the normal and failing heart develop T-wave alternans, but only the failing heart shows QRS alternans (although moderate) at rapid pacing. Moreover, T-wave alternans is significantly more pronounced in the failing heart. At rapid pacing, APD maps show areas of conduction block in the failing heart. Finally, accelerated pacing initiated wave reentry and breakup in the failing heart. Further, the onset of VF was not observed with an upregulation of SERCA, a potential drug therapy, using the same protocol. The changes introduced at the cell and tissue level have increased the failing heart’s susceptibility to dynamic instabilities and arrhythmias under rapid pacing. However, the observed increase in arrhythmogenic potential is not due to a steepening of the restitution curve (not present in our model), but rather to a novel blocking mechanism. Public Library of Science 2016-06-23 /pmc/articles/PMC4919062/ /pubmed/27336310 http://dx.doi.org/10.1371/journal.pcbi.1004968 Text en © 2016 Ponnaluri et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Ponnaluri, Aditya V. S. Perotti, Luigi E. Liu, Michael Qu, Zhilin Weiss, James N. Ennis, Daniel B. Klug, William S. Garfinkel, Alan Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation |
title | Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation |
title_full | Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation |
title_fullStr | Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation |
title_full_unstemmed | Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation |
title_short | Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation |
title_sort | electrophysiology of heart failure using a rabbit model: from the failing myocyte to ventricular fibrillation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4919062/ https://www.ncbi.nlm.nih.gov/pubmed/27336310 http://dx.doi.org/10.1371/journal.pcbi.1004968 |
work_keys_str_mv | AT ponnaluriadityavs electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation AT perottiluigie electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation AT liumichael electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation AT quzhilin electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation AT weissjamesn electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation AT ennisdanielb electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation AT klugwilliams electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation AT garfinkelalan electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation |