Cargando…

Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study

PURPOSE: A recently introduced direct drill-guiding implant surgery system features minimal tolerance of surgical instruments in the metal sleeve by using shank-modified drills and a sleeve-incorporated stereolithographic guide template. The purpose of this study was to evaluate the accuracy of this...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Du-Hyeong, An, Seo-Young, Hong, Min-Ho, Jeon, Kyoung-Bae, Lee, Kyu-Bok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4919491/
https://www.ncbi.nlm.nih.gov/pubmed/27350855
http://dx.doi.org/10.4047/jap.2016.8.3.207
_version_ 1782439256091787264
author Lee, Du-Hyeong
An, Seo-Young
Hong, Min-Ho
Jeon, Kyoung-Bae
Lee, Kyu-Bok
author_facet Lee, Du-Hyeong
An, Seo-Young
Hong, Min-Ho
Jeon, Kyoung-Bae
Lee, Kyu-Bok
author_sort Lee, Du-Hyeong
collection PubMed
description PURPOSE: A recently introduced direct drill-guiding implant surgery system features minimal tolerance of surgical instruments in the metal sleeve by using shank-modified drills and a sleeve-incorporated stereolithographic guide template. The purpose of this study was to evaluate the accuracy of this new guided surgery system in partially edentulous patients using geometric analyses. MATERIALS AND METHODS: For the study, 21 implants were placed in 11 consecutive patients using the direct drill-guiding implant surgery system. The stereolithographic surgical guide was fabricated using cone-beam computed tomography, digital scanning, computer-aided design and computer-assisted manufacturing, and additive manufacturing processes. After surgery, the positional and angular deviations between planned and placed implants were measured at the abutment level using implant-planning software. The Kruskal-Wallis test and Mann-Whitney U test were used to compare the deviations (α=.05). RESULTS: The mean horizontal deviations were 0.593 mm (SD 0.238) mesiodistally and 0.691 mm (SD 0.344) buccolingually. The mean vertical deviation was 0.925 mm (SD 0.376) occlusogingivally. The vertical deviation was significantly larger than the horizontal deviation (P=.018). The mean angular deviation was 2.024 degrees (SD 0.942) mesiodistally and 2.390 degrees (SD 1.142) buccolingually. CONCLUSION: The direct drill-guiding implant surgery system demonstrates high accuracy in placing implants. Use of the drill shank as the guiding component is an effective way for reducing tolerance.
format Online
Article
Text
id pubmed-4919491
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-49194912016-06-27 Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study Lee, Du-Hyeong An, Seo-Young Hong, Min-Ho Jeon, Kyoung-Bae Lee, Kyu-Bok J Adv Prosthodont Original Article PURPOSE: A recently introduced direct drill-guiding implant surgery system features minimal tolerance of surgical instruments in the metal sleeve by using shank-modified drills and a sleeve-incorporated stereolithographic guide template. The purpose of this study was to evaluate the accuracy of this new guided surgery system in partially edentulous patients using geometric analyses. MATERIALS AND METHODS: For the study, 21 implants were placed in 11 consecutive patients using the direct drill-guiding implant surgery system. The stereolithographic surgical guide was fabricated using cone-beam computed tomography, digital scanning, computer-aided design and computer-assisted manufacturing, and additive manufacturing processes. After surgery, the positional and angular deviations between planned and placed implants were measured at the abutment level using implant-planning software. The Kruskal-Wallis test and Mann-Whitney U test were used to compare the deviations (α=.05). RESULTS: The mean horizontal deviations were 0.593 mm (SD 0.238) mesiodistally and 0.691 mm (SD 0.344) buccolingually. The mean vertical deviation was 0.925 mm (SD 0.376) occlusogingivally. The vertical deviation was significantly larger than the horizontal deviation (P=.018). The mean angular deviation was 2.024 degrees (SD 0.942) mesiodistally and 2.390 degrees (SD 1.142) buccolingually. CONCLUSION: The direct drill-guiding implant surgery system demonstrates high accuracy in placing implants. Use of the drill shank as the guiding component is an effective way for reducing tolerance. The Korean Academy of Prosthodontics 2016-06 2016-06-17 /pmc/articles/PMC4919491/ /pubmed/27350855 http://dx.doi.org/10.4047/jap.2016.8.3.207 Text en © 2016 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Du-Hyeong
An, Seo-Young
Hong, Min-Ho
Jeon, Kyoung-Bae
Lee, Kyu-Bok
Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study
title Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study
title_full Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study
title_fullStr Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study
title_full_unstemmed Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study
title_short Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study
title_sort accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4919491/
https://www.ncbi.nlm.nih.gov/pubmed/27350855
http://dx.doi.org/10.4047/jap.2016.8.3.207
work_keys_str_mv AT leeduhyeong accuracyofadirectdrillguidingsystemwithminimaltoleranceofsurgicalinstrumentsusedforimplantsurgeryaprospectiveclinicalstudy
AT anseoyoung accuracyofadirectdrillguidingsystemwithminimaltoleranceofsurgicalinstrumentsusedforimplantsurgeryaprospectiveclinicalstudy
AT hongminho accuracyofadirectdrillguidingsystemwithminimaltoleranceofsurgicalinstrumentsusedforimplantsurgeryaprospectiveclinicalstudy
AT jeonkyoungbae accuracyofadirectdrillguidingsystemwithminimaltoleranceofsurgicalinstrumentsusedforimplantsurgeryaprospectiveclinicalstudy
AT leekyubok accuracyofadirectdrillguidingsystemwithminimaltoleranceofsurgicalinstrumentsusedforimplantsurgeryaprospectiveclinicalstudy