Cargando…

Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up

PURPOSE: to assess the efficacy of transcorporal artificial urinary sphincter (AUS) implantation on continence for male stress urinary incontinence in cases of prior surgical treatment or/and radiation failure, and as a first option in radiation patients. MATERIALS AND METHODS: From March 2007 to Au...

Descripción completa

Detalles Bibliográficos
Autores principales: Long, Erwann Le, Rebibo, John David, Nouhaud, Francois Xavier, Grise, Philippe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Urologia 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4920566/
https://www.ncbi.nlm.nih.gov/pubmed/27286112
http://dx.doi.org/10.1590/S1677-5538.IBJU.2015.0329
_version_ 1782439418605338624
author Long, Erwann Le
Rebibo, John David
Nouhaud, Francois Xavier
Grise, Philippe
author_facet Long, Erwann Le
Rebibo, John David
Nouhaud, Francois Xavier
Grise, Philippe
author_sort Long, Erwann Le
collection PubMed
description PURPOSE: to assess the efficacy of transcorporal artificial urinary sphincter (AUS) implantation on continence for male stress urinary incontinence in cases of prior surgical treatment or/and radiation failure, and as a first option in radiation patients. MATERIALS AND METHODS: From March 2007 to August 2012, 37 male patients were treated with transcorporal AUS AMS™ 800. Twelve patients had primary placement of transcorporal cuff, a surgical option due to a previous history of radiation and 25 patients had secondary procedure after failure of AUS or urinary incontinence surgery. Functional urinary outcomes were assessed by daily pad use, 24-hour Pad-test and ICIQ-SF questionnaire. Quality of life and satisfaction were assessed based on I-QoL and PGI-I questionnaires. RESULTS: After a median of 32 months, the continence rate (0 to 1 pad) was 69.7%. Median pad test was 17.5g (0-159), mean ICIQ-SF score was 7.3/21 (±5.4) and mean I-QoL score was 93.9/110. A total of 88% of the patients reported satisfaction with the AUS. The 5-year actuarial revision-free for AUS total device was 51%. Patients for primary implant for radiation were not more likely to experience revision than non-radiation patients. Preservation of erections was reported in half of the potent patients. CONCLUSIONS: Transcorporal AUS cuff placement is a useful alternative procedure option for severe male UI treatment, especially in patients with a compromised urethra after prior surgery or radiation. A high continence rate was reported and implantation as first option in radiation patients should be considered.
format Online
Article
Text
id pubmed-4920566
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Sociedade Brasileira de Urologia
record_format MEDLINE/PubMed
spelling pubmed-49205662016-06-27 Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up Long, Erwann Le Rebibo, John David Nouhaud, Francois Xavier Grise, Philippe Int Braz J Urol Original Article PURPOSE: to assess the efficacy of transcorporal artificial urinary sphincter (AUS) implantation on continence for male stress urinary incontinence in cases of prior surgical treatment or/and radiation failure, and as a first option in radiation patients. MATERIALS AND METHODS: From March 2007 to August 2012, 37 male patients were treated with transcorporal AUS AMS™ 800. Twelve patients had primary placement of transcorporal cuff, a surgical option due to a previous history of radiation and 25 patients had secondary procedure after failure of AUS or urinary incontinence surgery. Functional urinary outcomes were assessed by daily pad use, 24-hour Pad-test and ICIQ-SF questionnaire. Quality of life and satisfaction were assessed based on I-QoL and PGI-I questionnaires. RESULTS: After a median of 32 months, the continence rate (0 to 1 pad) was 69.7%. Median pad test was 17.5g (0-159), mean ICIQ-SF score was 7.3/21 (±5.4) and mean I-QoL score was 93.9/110. A total of 88% of the patients reported satisfaction with the AUS. The 5-year actuarial revision-free for AUS total device was 51%. Patients for primary implant for radiation were not more likely to experience revision than non-radiation patients. Preservation of erections was reported in half of the potent patients. CONCLUSIONS: Transcorporal AUS cuff placement is a useful alternative procedure option for severe male UI treatment, especially in patients with a compromised urethra after prior surgery or radiation. A high continence rate was reported and implantation as first option in radiation patients should be considered. Sociedade Brasileira de Urologia 2016 /pmc/articles/PMC4920566/ /pubmed/27286112 http://dx.doi.org/10.1590/S1677-5538.IBJU.2015.0329 Text en http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Long, Erwann Le
Rebibo, John David
Nouhaud, Francois Xavier
Grise, Philippe
Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up
title Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up
title_full Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up
title_fullStr Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up
title_full_unstemmed Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up
title_short Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up
title_sort transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. assessment with a minimum 2 year follow-up
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4920566/
https://www.ncbi.nlm.nih.gov/pubmed/27286112
http://dx.doi.org/10.1590/S1677-5538.IBJU.2015.0329
work_keys_str_mv AT longerwannle transcorporalartificialurinarysphincterinradiatedandnonradiatedcompromisedurethraassessmentwithaminimum2yearfollowup
AT rebibojohndavid transcorporalartificialurinarysphincterinradiatedandnonradiatedcompromisedurethraassessmentwithaminimum2yearfollowup
AT nouhaudfrancoisxavier transcorporalartificialurinarysphincterinradiatedandnonradiatedcompromisedurethraassessmentwithaminimum2yearfollowup
AT grisephilippe transcorporalartificialurinarysphincterinradiatedandnonradiatedcompromisedurethraassessmentwithaminimum2yearfollowup