Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up
PURPOSE: to assess the efficacy of transcorporal artificial urinary sphincter (AUS) implantation on continence for male stress urinary incontinence in cases of prior surgical treatment or/and radiation failure, and as a first option in radiation patients. MATERIALS AND METHODS: From March 2007 to Au...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira de Urologia
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4920566/ https://www.ncbi.nlm.nih.gov/pubmed/27286112 http://dx.doi.org/10.1590/S1677-5538.IBJU.2015.0329 |
_version_ | 1782439418605338624 |
---|---|
author | Long, Erwann Le Rebibo, John David Nouhaud, Francois Xavier Grise, Philippe |
author_facet | Long, Erwann Le Rebibo, John David Nouhaud, Francois Xavier Grise, Philippe |
author_sort | Long, Erwann Le |
collection | PubMed |
description | PURPOSE: to assess the efficacy of transcorporal artificial urinary sphincter (AUS) implantation on continence for male stress urinary incontinence in cases of prior surgical treatment or/and radiation failure, and as a first option in radiation patients. MATERIALS AND METHODS: From March 2007 to August 2012, 37 male patients were treated with transcorporal AUS AMS™ 800. Twelve patients had primary placement of transcorporal cuff, a surgical option due to a previous history of radiation and 25 patients had secondary procedure after failure of AUS or urinary incontinence surgery. Functional urinary outcomes were assessed by daily pad use, 24-hour Pad-test and ICIQ-SF questionnaire. Quality of life and satisfaction were assessed based on I-QoL and PGI-I questionnaires. RESULTS: After a median of 32 months, the continence rate (0 to 1 pad) was 69.7%. Median pad test was 17.5g (0-159), mean ICIQ-SF score was 7.3/21 (±5.4) and mean I-QoL score was 93.9/110. A total of 88% of the patients reported satisfaction with the AUS. The 5-year actuarial revision-free for AUS total device was 51%. Patients for primary implant for radiation were not more likely to experience revision than non-radiation patients. Preservation of erections was reported in half of the potent patients. CONCLUSIONS: Transcorporal AUS cuff placement is a useful alternative procedure option for severe male UI treatment, especially in patients with a compromised urethra after prior surgery or radiation. A high continence rate was reported and implantation as first option in radiation patients should be considered. |
format | Online Article Text |
id | pubmed-4920566 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Sociedade Brasileira de Urologia |
record_format | MEDLINE/PubMed |
spelling | pubmed-49205662016-06-27 Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up Long, Erwann Le Rebibo, John David Nouhaud, Francois Xavier Grise, Philippe Int Braz J Urol Original Article PURPOSE: to assess the efficacy of transcorporal artificial urinary sphincter (AUS) implantation on continence for male stress urinary incontinence in cases of prior surgical treatment or/and radiation failure, and as a first option in radiation patients. MATERIALS AND METHODS: From March 2007 to August 2012, 37 male patients were treated with transcorporal AUS AMS™ 800. Twelve patients had primary placement of transcorporal cuff, a surgical option due to a previous history of radiation and 25 patients had secondary procedure after failure of AUS or urinary incontinence surgery. Functional urinary outcomes were assessed by daily pad use, 24-hour Pad-test and ICIQ-SF questionnaire. Quality of life and satisfaction were assessed based on I-QoL and PGI-I questionnaires. RESULTS: After a median of 32 months, the continence rate (0 to 1 pad) was 69.7%. Median pad test was 17.5g (0-159), mean ICIQ-SF score was 7.3/21 (±5.4) and mean I-QoL score was 93.9/110. A total of 88% of the patients reported satisfaction with the AUS. The 5-year actuarial revision-free for AUS total device was 51%. Patients for primary implant for radiation were not more likely to experience revision than non-radiation patients. Preservation of erections was reported in half of the potent patients. CONCLUSIONS: Transcorporal AUS cuff placement is a useful alternative procedure option for severe male UI treatment, especially in patients with a compromised urethra after prior surgery or radiation. A high continence rate was reported and implantation as first option in radiation patients should be considered. Sociedade Brasileira de Urologia 2016 /pmc/articles/PMC4920566/ /pubmed/27286112 http://dx.doi.org/10.1590/S1677-5538.IBJU.2015.0329 Text en http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Long, Erwann Le Rebibo, John David Nouhaud, Francois Xavier Grise, Philippe Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up |
title | Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up |
title_full | Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up |
title_fullStr | Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up |
title_full_unstemmed | Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up |
title_short | Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up |
title_sort | transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. assessment with a minimum 2 year follow-up |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4920566/ https://www.ncbi.nlm.nih.gov/pubmed/27286112 http://dx.doi.org/10.1590/S1677-5538.IBJU.2015.0329 |
work_keys_str_mv | AT longerwannle transcorporalartificialurinarysphincterinradiatedandnonradiatedcompromisedurethraassessmentwithaminimum2yearfollowup AT rebibojohndavid transcorporalartificialurinarysphincterinradiatedandnonradiatedcompromisedurethraassessmentwithaminimum2yearfollowup AT nouhaudfrancoisxavier transcorporalartificialurinarysphincterinradiatedandnonradiatedcompromisedurethraassessmentwithaminimum2yearfollowup AT grisephilippe transcorporalartificialurinarysphincterinradiatedandnonradiatedcompromisedurethraassessmentwithaminimum2yearfollowup |