Cargando…

Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode

OBJECTIVES: To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. MATERIALS AND METHODS: We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the...

Descripción completa

Detalles Bibliográficos
Autores principales: Omar, Mohamed, Sarkissian, Carl, Jianbo, Li, Calle, Juan, Monga, Manoj
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Urologia 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4920573/
https://www.ncbi.nlm.nih.gov/pubmed/27286119
http://dx.doi.org/10.1590/S1677-5538.IBJU.2015.0071
_version_ 1782439420229582848
author Omar, Mohamed
Sarkissian, Carl
Jianbo, Li
Calle, Juan
Monga, Manoj
author_facet Omar, Mohamed
Sarkissian, Carl
Jianbo, Li
Calle, Juan
Monga, Manoj
author_sort Omar, Mohamed
collection PubMed
description OBJECTIVES: To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. MATERIALS AND METHODS: We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recent pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered an inaccurate result. RESULTS: A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). CONCLUSIONS: Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH.
format Online
Article
Text
id pubmed-4920573
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Sociedade Brasileira de Urologia
record_format MEDLINE/PubMed
spelling pubmed-49205732016-06-27 Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode Omar, Mohamed Sarkissian, Carl Jianbo, Li Calle, Juan Monga, Manoj Int Braz J Urol Original Article OBJECTIVES: To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. MATERIALS AND METHODS: We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recent pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered an inaccurate result. RESULTS: A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). CONCLUSIONS: Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH. Sociedade Brasileira de Urologia 2016 /pmc/articles/PMC4920573/ /pubmed/27286119 http://dx.doi.org/10.1590/S1677-5538.IBJU.2015.0071 Text en http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Omar, Mohamed
Sarkissian, Carl
Jianbo, Li
Calle, Juan
Monga, Manoj
Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode
title Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode
title_full Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode
title_fullStr Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode
title_full_unstemmed Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode
title_short Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode
title_sort dipstick spot urine ph does not accurately represent 24 hour urine ph measured by an electrode
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4920573/
https://www.ncbi.nlm.nih.gov/pubmed/27286119
http://dx.doi.org/10.1590/S1677-5538.IBJU.2015.0071
work_keys_str_mv AT omarmohamed dipstickspoturinephdoesnotaccuratelyrepresent24hoururinephmeasuredbyanelectrode
AT sarkissiancarl dipstickspoturinephdoesnotaccuratelyrepresent24hoururinephmeasuredbyanelectrode
AT jianboli dipstickspoturinephdoesnotaccuratelyrepresent24hoururinephmeasuredbyanelectrode
AT callejuan dipstickspoturinephdoesnotaccuratelyrepresent24hoururinephmeasuredbyanelectrode
AT mongamanoj dipstickspoturinephdoesnotaccuratelyrepresent24hoururinephmeasuredbyanelectrode