Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode
OBJECTIVES: To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. MATERIALS AND METHODS: We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira de Urologia
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4920573/ https://www.ncbi.nlm.nih.gov/pubmed/27286119 http://dx.doi.org/10.1590/S1677-5538.IBJU.2015.0071 |
_version_ | 1782439420229582848 |
---|---|
author | Omar, Mohamed Sarkissian, Carl Jianbo, Li Calle, Juan Monga, Manoj |
author_facet | Omar, Mohamed Sarkissian, Carl Jianbo, Li Calle, Juan Monga, Manoj |
author_sort | Omar, Mohamed |
collection | PubMed |
description | OBJECTIVES: To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. MATERIALS AND METHODS: We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recent pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered an inaccurate result. RESULTS: A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). CONCLUSIONS: Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH. |
format | Online Article Text |
id | pubmed-4920573 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Sociedade Brasileira de Urologia |
record_format | MEDLINE/PubMed |
spelling | pubmed-49205732016-06-27 Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode Omar, Mohamed Sarkissian, Carl Jianbo, Li Calle, Juan Monga, Manoj Int Braz J Urol Original Article OBJECTIVES: To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. MATERIALS AND METHODS: We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recent pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered an inaccurate result. RESULTS: A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). CONCLUSIONS: Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH. Sociedade Brasileira de Urologia 2016 /pmc/articles/PMC4920573/ /pubmed/27286119 http://dx.doi.org/10.1590/S1677-5538.IBJU.2015.0071 Text en http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Omar, Mohamed Sarkissian, Carl Jianbo, Li Calle, Juan Monga, Manoj Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode |
title | Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode |
title_full | Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode |
title_fullStr | Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode |
title_full_unstemmed | Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode |
title_short | Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode |
title_sort | dipstick spot urine ph does not accurately represent 24 hour urine ph measured by an electrode |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4920573/ https://www.ncbi.nlm.nih.gov/pubmed/27286119 http://dx.doi.org/10.1590/S1677-5538.IBJU.2015.0071 |
work_keys_str_mv | AT omarmohamed dipstickspoturinephdoesnotaccuratelyrepresent24hoururinephmeasuredbyanelectrode AT sarkissiancarl dipstickspoturinephdoesnotaccuratelyrepresent24hoururinephmeasuredbyanelectrode AT jianboli dipstickspoturinephdoesnotaccuratelyrepresent24hoururinephmeasuredbyanelectrode AT callejuan dipstickspoturinephdoesnotaccuratelyrepresent24hoururinephmeasuredbyanelectrode AT mongamanoj dipstickspoturinephdoesnotaccuratelyrepresent24hoururinephmeasuredbyanelectrode |