(36)Cl/Cl Accelerator-Mass-Spectrometry Standards: Verification of Their Serial-Dilution-Solution Preparations by Radioactivity Measurements

A consortium of accclerator-mass-spectrometry (AMS) laboratories recently prepared a series of (36)Cl/Cl isotopic ratio AMS standards by an eight-step serial gravimetric dilution scheme. Of the resulting nine solutions, only the latter six could be assayed by AMS to confirm the gravimetric dilution...

Descripción completa

Detalles Bibliográficos
Autores principales: Collé, R., Thomas, Joylene W. L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1993
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4922398/
https://www.ncbi.nlm.nih.gov/pubmed/28053491
http://dx.doi.org/10.6028/jres.098.043
_version_ 1782439615988236288
author Collé, R.
Thomas, Joylene W. L.
author_facet Collé, R.
Thomas, Joylene W. L.
author_sort Collé, R.
collection PubMed
description A consortium of accclerator-mass-spectrometry (AMS) laboratories recently prepared a series of (36)Cl/Cl isotopic ratio AMS standards by an eight-step serial gravimetric dilution scheme. Of the resulting nine solutions, only the latter six could be assayed by AMS to confirm the gravimetric dilution factors. This paper provides the results of relative radioactivity measurements on the first four solutions to verify the first three dilution factors. The fourth solution was the only dilution capable of being directly measured by both AMS and radionuclidic metrology of (36)Cl, and therefore its assay by radioactivity counting was deemed of considerable importance. Assays were performed by 4πβ(−) liquid scintillation (LS) counting of gravimetric aliquots of the solutions, with confirmatory measurements by 2πβ(−) gas-flow proportional counting of gravimetrically-prepared solid sources. The radioactivity measurements on the fourth solution were complex and difficult because of the conflicting combination of a low activity concentration (0.036 Bq · g(−1)) and high salt content (146 mg NaCl per g of solution). These conditions necessitated independent studies of the (36)Cl LS efficiency as a function of NaCl loading in the LS cocktails and of the feasibility of LS counting of precipitated samples, both of which are also reported here. The results of the radioactivity measurements confirmed the dilution factors for the first three solutions to absolute differences of about 1%, and that for the fourth solution to about 1% to 2%. The overall uncertainties for these verification measurements, at a relative three standard deviation uncertainty interval, were of comparable magnitude, i.e., in the range of ±1% to ±2% for the first three solutions and roughly ±3% for the fourth solution.
format Online
Article
Text
id pubmed-4922398
institution National Center for Biotechnology Information
language English
publishDate 1993
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-49223982017-01-04 (36)Cl/Cl Accelerator-Mass-Spectrometry Standards: Verification of Their Serial-Dilution-Solution Preparations by Radioactivity Measurements Collé, R. Thomas, Joylene W. L. J Res Natl Inst Stand Technol Article A consortium of accclerator-mass-spectrometry (AMS) laboratories recently prepared a series of (36)Cl/Cl isotopic ratio AMS standards by an eight-step serial gravimetric dilution scheme. Of the resulting nine solutions, only the latter six could be assayed by AMS to confirm the gravimetric dilution factors. This paper provides the results of relative radioactivity measurements on the first four solutions to verify the first three dilution factors. The fourth solution was the only dilution capable of being directly measured by both AMS and radionuclidic metrology of (36)Cl, and therefore its assay by radioactivity counting was deemed of considerable importance. Assays were performed by 4πβ(−) liquid scintillation (LS) counting of gravimetric aliquots of the solutions, with confirmatory measurements by 2πβ(−) gas-flow proportional counting of gravimetrically-prepared solid sources. The radioactivity measurements on the fourth solution were complex and difficult because of the conflicting combination of a low activity concentration (0.036 Bq · g(−1)) and high salt content (146 mg NaCl per g of solution). These conditions necessitated independent studies of the (36)Cl LS efficiency as a function of NaCl loading in the LS cocktails and of the feasibility of LS counting of precipitated samples, both of which are also reported here. The results of the radioactivity measurements confirmed the dilution factors for the first three solutions to absolute differences of about 1%, and that for the fourth solution to about 1% to 2%. The overall uncertainties for these verification measurements, at a relative three standard deviation uncertainty interval, were of comparable magnitude, i.e., in the range of ±1% to ±2% for the first three solutions and roughly ±3% for the fourth solution. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1993 /pmc/articles/PMC4922398/ /pubmed/28053491 http://dx.doi.org/10.6028/jres.098.043 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Collé, R.
Thomas, Joylene W. L.
(36)Cl/Cl Accelerator-Mass-Spectrometry Standards: Verification of Their Serial-Dilution-Solution Preparations by Radioactivity Measurements
title (36)Cl/Cl Accelerator-Mass-Spectrometry Standards: Verification of Their Serial-Dilution-Solution Preparations by Radioactivity Measurements
title_full (36)Cl/Cl Accelerator-Mass-Spectrometry Standards: Verification of Their Serial-Dilution-Solution Preparations by Radioactivity Measurements
title_fullStr (36)Cl/Cl Accelerator-Mass-Spectrometry Standards: Verification of Their Serial-Dilution-Solution Preparations by Radioactivity Measurements
title_full_unstemmed (36)Cl/Cl Accelerator-Mass-Spectrometry Standards: Verification of Their Serial-Dilution-Solution Preparations by Radioactivity Measurements
title_short (36)Cl/Cl Accelerator-Mass-Spectrometry Standards: Verification of Their Serial-Dilution-Solution Preparations by Radioactivity Measurements
title_sort (36)cl/cl accelerator-mass-spectrometry standards: verification of their serial-dilution-solution preparations by radioactivity measurements
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4922398/
https://www.ncbi.nlm.nih.gov/pubmed/28053491
http://dx.doi.org/10.6028/jres.098.043
work_keys_str_mv AT coller 36clclacceleratormassspectrometrystandardsverificationoftheirserialdilutionsolutionpreparationsbyradioactivitymeasurements
AT thomasjoylenewl 36clclacceleratormassspectrometrystandardsverificationoftheirserialdilutionsolutionpreparationsbyradioactivitymeasurements