Cargando…

The Diagnostic Performance of Thyroid US in Each Category of the Bethesda System for Reporting Thyroid Cytopathology

We aimed to evaluate the diagnostic performance of thyroid ultrasonography (US) in each category of the Bethesda system and analyze false positive/negative findings using US. This retrospective study included 622 thyroid nodules in 592 patients. The sensitivity, specificity, negative predictive valu...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, So Yoon, Hahn, Soo Yeon, Shin, Jung Hee, Ko, Eun Young, Oh, Young Lyun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4922578/
https://www.ncbi.nlm.nih.gov/pubmed/27348515
http://dx.doi.org/10.1371/journal.pone.0155898
_version_ 1782439632955244544
author Park, So Yoon
Hahn, Soo Yeon
Shin, Jung Hee
Ko, Eun Young
Oh, Young Lyun
author_facet Park, So Yoon
Hahn, Soo Yeon
Shin, Jung Hee
Ko, Eun Young
Oh, Young Lyun
author_sort Park, So Yoon
collection PubMed
description We aimed to evaluate the diagnostic performance of thyroid ultrasonography (US) in each category of the Bethesda system and analyze false positive/negative findings using US. This retrospective study included 622 thyroid nodules in 592 patients. The sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV) and accuracy of US in each category of the Bethesda system were evaluated. False positive/negative cases of US were analyzed. Out of the 622 total thyroid FNAs, 179 (28.8%) were malignant. The malignancy rates for the 6 categories were as follows: I (nondiagnostic): 9.7%, II (benign): 2.5%, III (atypia/follicular lesion of undetermined significance): 37.5%, IV (suspicious for follicular neoplasm): 5.7%, V (suspicious for malignancy): 100%, and VI (malignancy): 100%. The accuracies of US for the 6 categories were 92.5%, 95.6%, 70.8%, 94.3%, 95%, and 92.4% in category order. US showed the lowest sensitivity (50%) in Category IV. Category III demonstrated relatively low sensitivity (66.7%) and specificity (73.3%) due to a high incidence of follicular variant of papillary thyroid carcinoma and a low number of category III nodules. The most optimal performance of US was revealed in Category I with 88.9% sensitivity and 92.9% specificity. In 22 US false positive cases, the most frequent finding was associated with marked hypoechogenicity and the least finding was noncircumscribed margin. The most common US features of 19 false negative cases were circumscribed iso or hypoechoic nodules. These results highlight the excellent diagnostic performance of US in category I of the Bethesda system and the lowest sensitivity of US in category IV. Awareness of US interpreters regarding these pitfalls can minimize false positive/negative diagnoses and prevent unnecessary interventions.
format Online
Article
Text
id pubmed-4922578
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-49225782016-07-18 The Diagnostic Performance of Thyroid US in Each Category of the Bethesda System for Reporting Thyroid Cytopathology Park, So Yoon Hahn, Soo Yeon Shin, Jung Hee Ko, Eun Young Oh, Young Lyun PLoS One Research Article We aimed to evaluate the diagnostic performance of thyroid ultrasonography (US) in each category of the Bethesda system and analyze false positive/negative findings using US. This retrospective study included 622 thyroid nodules in 592 patients. The sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV) and accuracy of US in each category of the Bethesda system were evaluated. False positive/negative cases of US were analyzed. Out of the 622 total thyroid FNAs, 179 (28.8%) were malignant. The malignancy rates for the 6 categories were as follows: I (nondiagnostic): 9.7%, II (benign): 2.5%, III (atypia/follicular lesion of undetermined significance): 37.5%, IV (suspicious for follicular neoplasm): 5.7%, V (suspicious for malignancy): 100%, and VI (malignancy): 100%. The accuracies of US for the 6 categories were 92.5%, 95.6%, 70.8%, 94.3%, 95%, and 92.4% in category order. US showed the lowest sensitivity (50%) in Category IV. Category III demonstrated relatively low sensitivity (66.7%) and specificity (73.3%) due to a high incidence of follicular variant of papillary thyroid carcinoma and a low number of category III nodules. The most optimal performance of US was revealed in Category I with 88.9% sensitivity and 92.9% specificity. In 22 US false positive cases, the most frequent finding was associated with marked hypoechogenicity and the least finding was noncircumscribed margin. The most common US features of 19 false negative cases were circumscribed iso or hypoechoic nodules. These results highlight the excellent diagnostic performance of US in category I of the Bethesda system and the lowest sensitivity of US in category IV. Awareness of US interpreters regarding these pitfalls can minimize false positive/negative diagnoses and prevent unnecessary interventions. Public Library of Science 2016-06-27 /pmc/articles/PMC4922578/ /pubmed/27348515 http://dx.doi.org/10.1371/journal.pone.0155898 Text en © 2016 Park et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Park, So Yoon
Hahn, Soo Yeon
Shin, Jung Hee
Ko, Eun Young
Oh, Young Lyun
The Diagnostic Performance of Thyroid US in Each Category of the Bethesda System for Reporting Thyroid Cytopathology
title The Diagnostic Performance of Thyroid US in Each Category of the Bethesda System for Reporting Thyroid Cytopathology
title_full The Diagnostic Performance of Thyroid US in Each Category of the Bethesda System for Reporting Thyroid Cytopathology
title_fullStr The Diagnostic Performance of Thyroid US in Each Category of the Bethesda System for Reporting Thyroid Cytopathology
title_full_unstemmed The Diagnostic Performance of Thyroid US in Each Category of the Bethesda System for Reporting Thyroid Cytopathology
title_short The Diagnostic Performance of Thyroid US in Each Category of the Bethesda System for Reporting Thyroid Cytopathology
title_sort diagnostic performance of thyroid us in each category of the bethesda system for reporting thyroid cytopathology
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4922578/
https://www.ncbi.nlm.nih.gov/pubmed/27348515
http://dx.doi.org/10.1371/journal.pone.0155898
work_keys_str_mv AT parksoyoon thediagnosticperformanceofthyroidusineachcategoryofthebethesdasystemforreportingthyroidcytopathology
AT hahnsooyeon thediagnosticperformanceofthyroidusineachcategoryofthebethesdasystemforreportingthyroidcytopathology
AT shinjunghee thediagnosticperformanceofthyroidusineachcategoryofthebethesdasystemforreportingthyroidcytopathology
AT koeunyoung thediagnosticperformanceofthyroidusineachcategoryofthebethesdasystemforreportingthyroidcytopathology
AT ohyounglyun thediagnosticperformanceofthyroidusineachcategoryofthebethesdasystemforreportingthyroidcytopathology
AT parksoyoon diagnosticperformanceofthyroidusineachcategoryofthebethesdasystemforreportingthyroidcytopathology
AT hahnsooyeon diagnosticperformanceofthyroidusineachcategoryofthebethesdasystemforreportingthyroidcytopathology
AT shinjunghee diagnosticperformanceofthyroidusineachcategoryofthebethesdasystemforreportingthyroidcytopathology
AT koeunyoung diagnosticperformanceofthyroidusineachcategoryofthebethesdasystemforreportingthyroidcytopathology
AT ohyounglyun diagnosticperformanceofthyroidusineachcategoryofthebethesdasystemforreportingthyroidcytopathology