Cargando…

Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience

Background. Quantitative ultrasound measures are influenced by multiple external factors including examiner scanning force. Force feedback may foster the acquisition of reliable morphometry measures under a variety of scanning conditions. The purpose of this study was to determine the reliability of...

Descripción completa

Detalles Bibliográficos
Autores principales: Harris-Love, Michael O., Ismail, Catheeja, Monfaredi, Reza, Hernandez, Haniel J., Pennington, Donte, Woletz, Paula, McIntosh, Valerie, Adams, Bernadette, Blackman, Marc R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PeerJ Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4924341/
https://www.ncbi.nlm.nih.gov/pubmed/27366647
http://dx.doi.org/10.7717/peerj.2146
_version_ 1782439855913959424
author Harris-Love, Michael O.
Ismail, Catheeja
Monfaredi, Reza
Hernandez, Haniel J.
Pennington, Donte
Woletz, Paula
McIntosh, Valerie
Adams, Bernadette
Blackman, Marc R.
author_facet Harris-Love, Michael O.
Ismail, Catheeja
Monfaredi, Reza
Hernandez, Haniel J.
Pennington, Donte
Woletz, Paula
McIntosh, Valerie
Adams, Bernadette
Blackman, Marc R.
author_sort Harris-Love, Michael O.
collection PubMed
description Background. Quantitative ultrasound measures are influenced by multiple external factors including examiner scanning force. Force feedback may foster the acquisition of reliable morphometry measures under a variety of scanning conditions. The purpose of this study was to determine the reliability of force-feedback image acquisition and morphometry over a range of examiner-generated forces using a muscle tissue-mimicking ultrasound phantom. Methods. Sixty material thickness measures were acquired from a muscle tissue mimicking phantom using B-mode ultrasound scanning by six examiners with varied experience levels (i.e., experienced, intermediate, and novice). Estimates of interrater reliability and measurement error with force feedback scanning were determined for the examiners. In addition, criterion-based reliability was determined using material deformation values across a range of examiner scanning forces (1–10 Newtons) via automated and manually acquired image capture methods using force feedback. Results. All examiners demonstrated acceptable interrater reliability (intraclass correlation coefficient, ICC = .98, p < .001) for material thickness measures obtained using force feedback. Individual examiners exhibited acceptable reliability with the criterion-based reference measures (ICC > .90, p < .001), independent of their level of experience. The measurement error among all examiners was 1.5%–2.9% across all applied stress conditions. Conclusion. Manual image capture with force feedback may aid the reliability of morphometry measures across a range of examiner scanning forces, and allow for consistent performance among examiners with differing levels of experience.
format Online
Article
Text
id pubmed-4924341
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher PeerJ Inc.
record_format MEDLINE/PubMed
spelling pubmed-49243412016-06-30 Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience Harris-Love, Michael O. Ismail, Catheeja Monfaredi, Reza Hernandez, Haniel J. Pennington, Donte Woletz, Paula McIntosh, Valerie Adams, Bernadette Blackman, Marc R. PeerJ Evidence Based Medicine Background. Quantitative ultrasound measures are influenced by multiple external factors including examiner scanning force. Force feedback may foster the acquisition of reliable morphometry measures under a variety of scanning conditions. The purpose of this study was to determine the reliability of force-feedback image acquisition and morphometry over a range of examiner-generated forces using a muscle tissue-mimicking ultrasound phantom. Methods. Sixty material thickness measures were acquired from a muscle tissue mimicking phantom using B-mode ultrasound scanning by six examiners with varied experience levels (i.e., experienced, intermediate, and novice). Estimates of interrater reliability and measurement error with force feedback scanning were determined for the examiners. In addition, criterion-based reliability was determined using material deformation values across a range of examiner scanning forces (1–10 Newtons) via automated and manually acquired image capture methods using force feedback. Results. All examiners demonstrated acceptable interrater reliability (intraclass correlation coefficient, ICC = .98, p < .001) for material thickness measures obtained using force feedback. Individual examiners exhibited acceptable reliability with the criterion-based reference measures (ICC > .90, p < .001), independent of their level of experience. The measurement error among all examiners was 1.5%–2.9% across all applied stress conditions. Conclusion. Manual image capture with force feedback may aid the reliability of morphometry measures across a range of examiner scanning forces, and allow for consistent performance among examiners with differing levels of experience. PeerJ Inc. 2016-06-21 /pmc/articles/PMC4924341/ /pubmed/27366647 http://dx.doi.org/10.7717/peerj.2146 Text en http://creativecommons.org/publicdomain/zero/1.0/ This is an open access article, free of all copyright, made available under the Creative Commons Public Domain Dedication (http://creativecommons.org/publicdomain/zero/1.0/) . This work may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose.
spellingShingle Evidence Based Medicine
Harris-Love, Michael O.
Ismail, Catheeja
Monfaredi, Reza
Hernandez, Haniel J.
Pennington, Donte
Woletz, Paula
McIntosh, Valerie
Adams, Bernadette
Blackman, Marc R.
Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience
title Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience
title_full Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience
title_fullStr Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience
title_full_unstemmed Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience
title_short Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience
title_sort interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience
topic Evidence Based Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4924341/
https://www.ncbi.nlm.nih.gov/pubmed/27366647
http://dx.doi.org/10.7717/peerj.2146
work_keys_str_mv AT harrislovemichaelo interraterreliabilityofquantitativeultrasoundusingforcefeedbackamongexaminerswithvariedlevelsofexperience
AT ismailcatheeja interraterreliabilityofquantitativeultrasoundusingforcefeedbackamongexaminerswithvariedlevelsofexperience
AT monfaredireza interraterreliabilityofquantitativeultrasoundusingforcefeedbackamongexaminerswithvariedlevelsofexperience
AT hernandezhanielj interraterreliabilityofquantitativeultrasoundusingforcefeedbackamongexaminerswithvariedlevelsofexperience
AT penningtondonte interraterreliabilityofquantitativeultrasoundusingforcefeedbackamongexaminerswithvariedlevelsofexperience
AT woletzpaula interraterreliabilityofquantitativeultrasoundusingforcefeedbackamongexaminerswithvariedlevelsofexperience
AT mcintoshvalerie interraterreliabilityofquantitativeultrasoundusingforcefeedbackamongexaminerswithvariedlevelsofexperience
AT adamsbernadette interraterreliabilityofquantitativeultrasoundusingforcefeedbackamongexaminerswithvariedlevelsofexperience
AT blackmanmarcr interraterreliabilityofquantitativeultrasoundusingforcefeedbackamongexaminerswithvariedlevelsofexperience