Cargando…
The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions
PURPOSE: The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. MATERIALS AND METHODS:...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Oral and Maxillofacial Radiology
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4925656/ https://www.ncbi.nlm.nih.gov/pubmed/27358816 http://dx.doi.org/10.5624/isd.2016.46.2.93 |
_version_ | 1782439973307285504 |
---|---|
author | Ganguly, Rumpa Ramesh, Aruna Pagni, Sarah |
author_facet | Ganguly, Rumpa Ramesh, Aruna Pagni, Sarah |
author_sort | Ganguly, Rumpa |
collection | PubMed |
description | PURPOSE: The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. MATERIALS AND METHODS: Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view (13 cm×16 cm) and small field of view (5 cm×8 cm) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. RESULTS: The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. CONCLUSION: The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements. |
format | Online Article Text |
id | pubmed-4925656 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Korean Academy of Oral and Maxillofacial Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-49256562016-06-29 The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions Ganguly, Rumpa Ramesh, Aruna Pagni, Sarah Imaging Sci Dent Original Article PURPOSE: The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. MATERIALS AND METHODS: Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view (13 cm×16 cm) and small field of view (5 cm×8 cm) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. RESULTS: The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. CONCLUSION: The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements. Korean Academy of Oral and Maxillofacial Radiology 2016-06 2016-06-23 /pmc/articles/PMC4925656/ /pubmed/27358816 http://dx.doi.org/10.5624/isd.2016.46.2.93 Text en Copyright © 2016 by Korean Academy of Oral and Maxillofacial Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Ganguly, Rumpa Ramesh, Aruna Pagni, Sarah The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions |
title | The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions |
title_full | The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions |
title_fullStr | The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions |
title_full_unstemmed | The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions |
title_short | The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions |
title_sort | accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4925656/ https://www.ncbi.nlm.nih.gov/pubmed/27358816 http://dx.doi.org/10.5624/isd.2016.46.2.93 |
work_keys_str_mv | AT gangulyrumpa theaccuracyoflinearmeasurementsofmaxillaryandmandibularedentuloussitesinconebeamcomputedtomographyimageswithdifferentfieldsofviewandvoxelsizesundersimulatedclinicalconditions AT ramesharuna theaccuracyoflinearmeasurementsofmaxillaryandmandibularedentuloussitesinconebeamcomputedtomographyimageswithdifferentfieldsofviewandvoxelsizesundersimulatedclinicalconditions AT pagnisarah theaccuracyoflinearmeasurementsofmaxillaryandmandibularedentuloussitesinconebeamcomputedtomographyimageswithdifferentfieldsofviewandvoxelsizesundersimulatedclinicalconditions AT gangulyrumpa accuracyoflinearmeasurementsofmaxillaryandmandibularedentuloussitesinconebeamcomputedtomographyimageswithdifferentfieldsofviewandvoxelsizesundersimulatedclinicalconditions AT ramesharuna accuracyoflinearmeasurementsofmaxillaryandmandibularedentuloussitesinconebeamcomputedtomographyimageswithdifferentfieldsofviewandvoxelsizesundersimulatedclinicalconditions AT pagnisarah accuracyoflinearmeasurementsofmaxillaryandmandibularedentuloussitesinconebeamcomputedtomographyimageswithdifferentfieldsofviewandvoxelsizesundersimulatedclinicalconditions |