Cargando…
Near-Infrared Fluorescence Lymphatic Imaging to Reconsider Occlusion Pressure of Superficial Lymphatic Collectors in Upper Extremities of Healthy Volunteers
Background: There are very little scientific data on occlusion pressure for superficial lymphatic collectors. Given its importance in determining the transport capacity of lymphatic vessels, it is crucial to know its value. The novel method of near-infrared fluorescence lymphatic imaging (NIRFLI) ca...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Mary Ann Liebert, Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4926199/ https://www.ncbi.nlm.nih.gov/pubmed/27167187 http://dx.doi.org/10.1089/lrb.2015.0040 |
_version_ | 1782440066547712000 |
---|---|
author | Belgrado, Jean-Paul Vandermeeren, Liesbeth Vankerckhove, Sophie Valsamis, Jean-Baptiste Malloizel-Delaunay, Julie Moraine, Jean-Jacques Liebens, Fabienne |
author_facet | Belgrado, Jean-Paul Vandermeeren, Liesbeth Vankerckhove, Sophie Valsamis, Jean-Baptiste Malloizel-Delaunay, Julie Moraine, Jean-Jacques Liebens, Fabienne |
author_sort | Belgrado, Jean-Paul |
collection | PubMed |
description | Background: There are very little scientific data on occlusion pressure for superficial lymphatic collectors. Given its importance in determining the transport capacity of lymphatic vessels, it is crucial to know its value. The novel method of near-infrared fluorescence lymphatic imaging (NIRFLI) can be used to visualize lymphatic flow in real time. The goal of this study was to see if this method could be used to measure the lymphatic occlusion pressure. Methods: We observed and recorded lymph flow in the upper limb of healthy volunteers through a transparent cuff using near-infrared fluorescence lymphatic imaging. After obtaining a baseline of the lymph flow without pressure inside the cuff, the cuff was inflated by increments of 10 mm Hg starting at 30 mm Hg. A NIRFLI guided manual lymphatic drainage technique named “Fill & Flush Drainage Method” was performed during the measurement to promote lymph flow. Lymphatic occlusion pressure was determined by observing when lymph flow stopped under the cuff. Results: We measured the lymphatic occlusion pressure on 30 healthy volunteers (11 men and 19 women). Mean lymphatic occlusion pressure in the upper limb was 86 mm Hg (CI ±3.7 mm Hg, α = 0.5%). No significant differences were found between age groups (p = 0.18), gender (p = 0.12), or limb side (p = 0.85). Conclusions: NIRFLI, a transparent sphygmomanometer cuff and the “Fill and Flush” manual lymphatic drainage method were used to measure the lymphatic occlusion pressure in 30 healthy humans. That combination of these techniques allows the visualization of the lymph flow in real time, while ensuring the continuous filling of the lymph collectors during the measurement session, reducing false negative observations. The measured occlusion pressures are much higher than previously described in the medical literature. |
format | Online Article Text |
id | pubmed-4926199 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Mary Ann Liebert, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-49261992016-07-25 Near-Infrared Fluorescence Lymphatic Imaging to Reconsider Occlusion Pressure of Superficial Lymphatic Collectors in Upper Extremities of Healthy Volunteers Belgrado, Jean-Paul Vandermeeren, Liesbeth Vankerckhove, Sophie Valsamis, Jean-Baptiste Malloizel-Delaunay, Julie Moraine, Jean-Jacques Liebens, Fabienne Lymphat Res Biol Original Articles Background: There are very little scientific data on occlusion pressure for superficial lymphatic collectors. Given its importance in determining the transport capacity of lymphatic vessels, it is crucial to know its value. The novel method of near-infrared fluorescence lymphatic imaging (NIRFLI) can be used to visualize lymphatic flow in real time. The goal of this study was to see if this method could be used to measure the lymphatic occlusion pressure. Methods: We observed and recorded lymph flow in the upper limb of healthy volunteers through a transparent cuff using near-infrared fluorescence lymphatic imaging. After obtaining a baseline of the lymph flow without pressure inside the cuff, the cuff was inflated by increments of 10 mm Hg starting at 30 mm Hg. A NIRFLI guided manual lymphatic drainage technique named “Fill & Flush Drainage Method” was performed during the measurement to promote lymph flow. Lymphatic occlusion pressure was determined by observing when lymph flow stopped under the cuff. Results: We measured the lymphatic occlusion pressure on 30 healthy volunteers (11 men and 19 women). Mean lymphatic occlusion pressure in the upper limb was 86 mm Hg (CI ±3.7 mm Hg, α = 0.5%). No significant differences were found between age groups (p = 0.18), gender (p = 0.12), or limb side (p = 0.85). Conclusions: NIRFLI, a transparent sphygmomanometer cuff and the “Fill and Flush” manual lymphatic drainage method were used to measure the lymphatic occlusion pressure in 30 healthy humans. That combination of these techniques allows the visualization of the lymph flow in real time, while ensuring the continuous filling of the lymph collectors during the measurement session, reducing false negative observations. The measured occlusion pressures are much higher than previously described in the medical literature. Mary Ann Liebert, Inc. 2016-06-01 /pmc/articles/PMC4926199/ /pubmed/27167187 http://dx.doi.org/10.1089/lrb.2015.0040 Text en © Belgrado et al, 2016; Published by Mary Ann Liebert, Inc. This Open Access article is distributed under the terms of the Creative Commons Attribution Noncommercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Original Articles Belgrado, Jean-Paul Vandermeeren, Liesbeth Vankerckhove, Sophie Valsamis, Jean-Baptiste Malloizel-Delaunay, Julie Moraine, Jean-Jacques Liebens, Fabienne Near-Infrared Fluorescence Lymphatic Imaging to Reconsider Occlusion Pressure of Superficial Lymphatic Collectors in Upper Extremities of Healthy Volunteers |
title | Near-Infrared Fluorescence Lymphatic Imaging to Reconsider Occlusion Pressure of Superficial Lymphatic Collectors in Upper Extremities of Healthy Volunteers |
title_full | Near-Infrared Fluorescence Lymphatic Imaging to Reconsider Occlusion Pressure of Superficial Lymphatic Collectors in Upper Extremities of Healthy Volunteers |
title_fullStr | Near-Infrared Fluorescence Lymphatic Imaging to Reconsider Occlusion Pressure of Superficial Lymphatic Collectors in Upper Extremities of Healthy Volunteers |
title_full_unstemmed | Near-Infrared Fluorescence Lymphatic Imaging to Reconsider Occlusion Pressure of Superficial Lymphatic Collectors in Upper Extremities of Healthy Volunteers |
title_short | Near-Infrared Fluorescence Lymphatic Imaging to Reconsider Occlusion Pressure of Superficial Lymphatic Collectors in Upper Extremities of Healthy Volunteers |
title_sort | near-infrared fluorescence lymphatic imaging to reconsider occlusion pressure of superficial lymphatic collectors in upper extremities of healthy volunteers |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4926199/ https://www.ncbi.nlm.nih.gov/pubmed/27167187 http://dx.doi.org/10.1089/lrb.2015.0040 |
work_keys_str_mv | AT belgradojeanpaul nearinfraredfluorescencelymphaticimagingtoreconsiderocclusionpressureofsuperficiallymphaticcollectorsinupperextremitiesofhealthyvolunteers AT vandermeerenliesbeth nearinfraredfluorescencelymphaticimagingtoreconsiderocclusionpressureofsuperficiallymphaticcollectorsinupperextremitiesofhealthyvolunteers AT vankerckhovesophie nearinfraredfluorescencelymphaticimagingtoreconsiderocclusionpressureofsuperficiallymphaticcollectorsinupperextremitiesofhealthyvolunteers AT valsamisjeanbaptiste nearinfraredfluorescencelymphaticimagingtoreconsiderocclusionpressureofsuperficiallymphaticcollectorsinupperextremitiesofhealthyvolunteers AT malloizeldelaunayjulie nearinfraredfluorescencelymphaticimagingtoreconsiderocclusionpressureofsuperficiallymphaticcollectorsinupperextremitiesofhealthyvolunteers AT morainejeanjacques nearinfraredfluorescencelymphaticimagingtoreconsiderocclusionpressureofsuperficiallymphaticcollectorsinupperextremitiesofhealthyvolunteers AT liebensfabienne nearinfraredfluorescencelymphaticimagingtoreconsiderocclusionpressureofsuperficiallymphaticcollectorsinupperextremitiesofhealthyvolunteers |