Cargando…

Computational imaging with a balanced detector

Single-pixel cameras allow to obtain images in a wide range of challenging scenarios, including broad regions of the electromagnetic spectrum and through scattering media. However, there still exist several drawbacks that single-pixel architectures must address, such as acquisition speed and imaging...

Descripción completa

Detalles Bibliográficos
Autores principales: Soldevila, F., Clemente, P., Tajahuerce, E., Uribe-Patarroyo, N., Andrés, P., Lancis, J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4926225/
https://www.ncbi.nlm.nih.gov/pubmed/27353733
http://dx.doi.org/10.1038/srep29181
_version_ 1782440071555710976
author Soldevila, F.
Clemente, P.
Tajahuerce, E.
Uribe-Patarroyo, N.
Andrés, P.
Lancis, J.
author_facet Soldevila, F.
Clemente, P.
Tajahuerce, E.
Uribe-Patarroyo, N.
Andrés, P.
Lancis, J.
author_sort Soldevila, F.
collection PubMed
description Single-pixel cameras allow to obtain images in a wide range of challenging scenarios, including broad regions of the electromagnetic spectrum and through scattering media. However, there still exist several drawbacks that single-pixel architectures must address, such as acquisition speed and imaging in the presence of ambient light. In this work we introduce balanced detection in combination with simultaneous complementary illumination in a single-pixel camera. This approach enables to acquire information even when the power of the parasite signal is higher than the signal itself. Furthermore, this novel detection scheme increases both the frame rate and the signal-to-noise ratio of the system. By means of a fast digital micromirror device together with a low numerical aperture collecting system, we are able to produce a live-feed video with a resolution of 64 × 64 pixels at 5 Hz. With advanced undersampling techniques, such as compressive sensing, we can acquire information at rates of 25 Hz. By using this strategy, we foresee real-time biological imaging with large area detectors in conditions where array sensors are unable to operate properly, such as infrared imaging and dealing with objects embedded in turbid media.
format Online
Article
Text
id pubmed-4926225
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-49262252016-07-01 Computational imaging with a balanced detector Soldevila, F. Clemente, P. Tajahuerce, E. Uribe-Patarroyo, N. Andrés, P. Lancis, J. Sci Rep Article Single-pixel cameras allow to obtain images in a wide range of challenging scenarios, including broad regions of the electromagnetic spectrum and through scattering media. However, there still exist several drawbacks that single-pixel architectures must address, such as acquisition speed and imaging in the presence of ambient light. In this work we introduce balanced detection in combination with simultaneous complementary illumination in a single-pixel camera. This approach enables to acquire information even when the power of the parasite signal is higher than the signal itself. Furthermore, this novel detection scheme increases both the frame rate and the signal-to-noise ratio of the system. By means of a fast digital micromirror device together with a low numerical aperture collecting system, we are able to produce a live-feed video with a resolution of 64 × 64 pixels at 5 Hz. With advanced undersampling techniques, such as compressive sensing, we can acquire information at rates of 25 Hz. By using this strategy, we foresee real-time biological imaging with large area detectors in conditions where array sensors are unable to operate properly, such as infrared imaging and dealing with objects embedded in turbid media. Nature Publishing Group 2016-06-29 /pmc/articles/PMC4926225/ /pubmed/27353733 http://dx.doi.org/10.1038/srep29181 Text en Copyright © 2016, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Soldevila, F.
Clemente, P.
Tajahuerce, E.
Uribe-Patarroyo, N.
Andrés, P.
Lancis, J.
Computational imaging with a balanced detector
title Computational imaging with a balanced detector
title_full Computational imaging with a balanced detector
title_fullStr Computational imaging with a balanced detector
title_full_unstemmed Computational imaging with a balanced detector
title_short Computational imaging with a balanced detector
title_sort computational imaging with a balanced detector
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4926225/
https://www.ncbi.nlm.nih.gov/pubmed/27353733
http://dx.doi.org/10.1038/srep29181
work_keys_str_mv AT soldevilaf computationalimagingwithabalanceddetector
AT clementep computationalimagingwithabalanceddetector
AT tajahuercee computationalimagingwithabalanceddetector
AT uribepatarroyon computationalimagingwithabalanceddetector
AT andresp computationalimagingwithabalanceddetector
AT lancisj computationalimagingwithabalanceddetector