Cargando…
Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening
The ability of pathogens to survive cheese ripening is a food-security concern. Therefore, this study aimed to evaluate the performance of two alternative methods of analysis of Listeria during the ripening of artisanal Minas cheese. These methods were tested and compared with the conventional metho...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4927643/ https://www.ncbi.nlm.nih.gov/pubmed/27268116 http://dx.doi.org/10.1016/j.bjm.2016.04.006 |
_version_ | 1782440294245990400 |
---|---|
author | Mata, Gardênia Márcia Silva Campos Martins, Evandro Machado, Solimar Gonçalves Pinto, Maximiliano Soares de Carvalho, Antônio Fernandes Vanetti, Maria Cristina Dantas |
author_facet | Mata, Gardênia Márcia Silva Campos Martins, Evandro Machado, Solimar Gonçalves Pinto, Maximiliano Soares de Carvalho, Antônio Fernandes Vanetti, Maria Cristina Dantas |
author_sort | Mata, Gardênia Márcia Silva Campos |
collection | PubMed |
description | The ability of pathogens to survive cheese ripening is a food-security concern. Therefore, this study aimed to evaluate the performance of two alternative methods of analysis of Listeria during the ripening of artisanal Minas cheese. These methods were tested and compared with the conventional method: Lateral Flow System™, in cheeses produced on laboratory scale using raw milk collected from different farms and inoculated with Listeria innocua; and VIDAS(®)-LMO, in cheese samples collected from different manufacturers in Serro, Minas Gerais, Brazil. These samples were also characterized in terms of lactic acid bacteria, coliforms and physical–chemical analysis. In the inoculated samples, L. innocua was detected by Lateral Flow System™ method with 33% false-negative and 68% accuracy results. L. innocua was only detected in the inoculated samples by the conventional method at 60-days of cheese ripening. L. monocytogenes was not detected by the conventional and the VIDAS(®)-LMO methods in cheese samples collected from different manufacturers, which impairs evaluating the performance of this alternative method. We concluded that the conventional method provided a better recovery of L. innocua throughout cheese ripening, being able to detect L. innocua at 60-day, aging period which is required by the current legislation. |
format | Online Article Text |
id | pubmed-4927643 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-49276432016-07-13 Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening Mata, Gardênia Márcia Silva Campos Martins, Evandro Machado, Solimar Gonçalves Pinto, Maximiliano Soares de Carvalho, Antônio Fernandes Vanetti, Maria Cristina Dantas Braz J Microbiol Food Microbiology The ability of pathogens to survive cheese ripening is a food-security concern. Therefore, this study aimed to evaluate the performance of two alternative methods of analysis of Listeria during the ripening of artisanal Minas cheese. These methods were tested and compared with the conventional method: Lateral Flow System™, in cheeses produced on laboratory scale using raw milk collected from different farms and inoculated with Listeria innocua; and VIDAS(®)-LMO, in cheese samples collected from different manufacturers in Serro, Minas Gerais, Brazil. These samples were also characterized in terms of lactic acid bacteria, coliforms and physical–chemical analysis. In the inoculated samples, L. innocua was detected by Lateral Flow System™ method with 33% false-negative and 68% accuracy results. L. innocua was only detected in the inoculated samples by the conventional method at 60-days of cheese ripening. L. monocytogenes was not detected by the conventional and the VIDAS(®)-LMO methods in cheese samples collected from different manufacturers, which impairs evaluating the performance of this alternative method. We concluded that the conventional method provided a better recovery of L. innocua throughout cheese ripening, being able to detect L. innocua at 60-day, aging period which is required by the current legislation. Elsevier 2016-04-22 /pmc/articles/PMC4927643/ /pubmed/27268116 http://dx.doi.org/10.1016/j.bjm.2016.04.006 Text en © 2016 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Food Microbiology Mata, Gardênia Márcia Silva Campos Martins, Evandro Machado, Solimar Gonçalves Pinto, Maximiliano Soares de Carvalho, Antônio Fernandes Vanetti, Maria Cristina Dantas Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening |
title | Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening |
title_full | Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening |
title_fullStr | Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening |
title_full_unstemmed | Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening |
title_short | Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening |
title_sort | performance of two alternative methods for listeria detection throughout serro minas cheese ripening |
topic | Food Microbiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4927643/ https://www.ncbi.nlm.nih.gov/pubmed/27268116 http://dx.doi.org/10.1016/j.bjm.2016.04.006 |
work_keys_str_mv | AT matagardeniamarciasilvacampos performanceoftwoalternativemethodsforlisteriadetectionthroughoutserrominascheeseripening AT martinsevandro performanceoftwoalternativemethodsforlisteriadetectionthroughoutserrominascheeseripening AT machadosolimargoncalves performanceoftwoalternativemethodsforlisteriadetectionthroughoutserrominascheeseripening AT pintomaximilianosoares performanceoftwoalternativemethodsforlisteriadetectionthroughoutserrominascheeseripening AT decarvalhoantoniofernandes performanceoftwoalternativemethodsforlisteriadetectionthroughoutserrominascheeseripening AT vanettimariacristinadantas performanceoftwoalternativemethodsforlisteriadetectionthroughoutserrominascheeseripening |