Cargando…

Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening

The ability of pathogens to survive cheese ripening is a food-security concern. Therefore, this study aimed to evaluate the performance of two alternative methods of analysis of Listeria during the ripening of artisanal Minas cheese. These methods were tested and compared with the conventional metho...

Descripción completa

Detalles Bibliográficos
Autores principales: Mata, Gardênia Márcia Silva Campos, Martins, Evandro, Machado, Solimar Gonçalves, Pinto, Maximiliano Soares, de Carvalho, Antônio Fernandes, Vanetti, Maria Cristina Dantas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4927643/
https://www.ncbi.nlm.nih.gov/pubmed/27268116
http://dx.doi.org/10.1016/j.bjm.2016.04.006
_version_ 1782440294245990400
author Mata, Gardênia Márcia Silva Campos
Martins, Evandro
Machado, Solimar Gonçalves
Pinto, Maximiliano Soares
de Carvalho, Antônio Fernandes
Vanetti, Maria Cristina Dantas
author_facet Mata, Gardênia Márcia Silva Campos
Martins, Evandro
Machado, Solimar Gonçalves
Pinto, Maximiliano Soares
de Carvalho, Antônio Fernandes
Vanetti, Maria Cristina Dantas
author_sort Mata, Gardênia Márcia Silva Campos
collection PubMed
description The ability of pathogens to survive cheese ripening is a food-security concern. Therefore, this study aimed to evaluate the performance of two alternative methods of analysis of Listeria during the ripening of artisanal Minas cheese. These methods were tested and compared with the conventional method: Lateral Flow System™, in cheeses produced on laboratory scale using raw milk collected from different farms and inoculated with Listeria innocua; and VIDAS(®)-LMO, in cheese samples collected from different manufacturers in Serro, Minas Gerais, Brazil. These samples were also characterized in terms of lactic acid bacteria, coliforms and physical–chemical analysis. In the inoculated samples, L. innocua was detected by Lateral Flow System™ method with 33% false-negative and 68% accuracy results. L. innocua was only detected in the inoculated samples by the conventional method at 60-days of cheese ripening. L. monocytogenes was not detected by the conventional and the VIDAS(®)-LMO methods in cheese samples collected from different manufacturers, which impairs evaluating the performance of this alternative method. We concluded that the conventional method provided a better recovery of L. innocua throughout cheese ripening, being able to detect L. innocua at 60-day, aging period which is required by the current legislation.
format Online
Article
Text
id pubmed-4927643
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-49276432016-07-13 Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening Mata, Gardênia Márcia Silva Campos Martins, Evandro Machado, Solimar Gonçalves Pinto, Maximiliano Soares de Carvalho, Antônio Fernandes Vanetti, Maria Cristina Dantas Braz J Microbiol Food Microbiology The ability of pathogens to survive cheese ripening is a food-security concern. Therefore, this study aimed to evaluate the performance of two alternative methods of analysis of Listeria during the ripening of artisanal Minas cheese. These methods were tested and compared with the conventional method: Lateral Flow System™, in cheeses produced on laboratory scale using raw milk collected from different farms and inoculated with Listeria innocua; and VIDAS(®)-LMO, in cheese samples collected from different manufacturers in Serro, Minas Gerais, Brazil. These samples were also characterized in terms of lactic acid bacteria, coliforms and physical–chemical analysis. In the inoculated samples, L. innocua was detected by Lateral Flow System™ method with 33% false-negative and 68% accuracy results. L. innocua was only detected in the inoculated samples by the conventional method at 60-days of cheese ripening. L. monocytogenes was not detected by the conventional and the VIDAS(®)-LMO methods in cheese samples collected from different manufacturers, which impairs evaluating the performance of this alternative method. We concluded that the conventional method provided a better recovery of L. innocua throughout cheese ripening, being able to detect L. innocua at 60-day, aging period which is required by the current legislation. Elsevier 2016-04-22 /pmc/articles/PMC4927643/ /pubmed/27268116 http://dx.doi.org/10.1016/j.bjm.2016.04.006 Text en © 2016 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Food Microbiology
Mata, Gardênia Márcia Silva Campos
Martins, Evandro
Machado, Solimar Gonçalves
Pinto, Maximiliano Soares
de Carvalho, Antônio Fernandes
Vanetti, Maria Cristina Dantas
Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening
title Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening
title_full Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening
title_fullStr Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening
title_full_unstemmed Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening
title_short Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening
title_sort performance of two alternative methods for listeria detection throughout serro minas cheese ripening
topic Food Microbiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4927643/
https://www.ncbi.nlm.nih.gov/pubmed/27268116
http://dx.doi.org/10.1016/j.bjm.2016.04.006
work_keys_str_mv AT matagardeniamarciasilvacampos performanceoftwoalternativemethodsforlisteriadetectionthroughoutserrominascheeseripening
AT martinsevandro performanceoftwoalternativemethodsforlisteriadetectionthroughoutserrominascheeseripening
AT machadosolimargoncalves performanceoftwoalternativemethodsforlisteriadetectionthroughoutserrominascheeseripening
AT pintomaximilianosoares performanceoftwoalternativemethodsforlisteriadetectionthroughoutserrominascheeseripening
AT decarvalhoantoniofernandes performanceoftwoalternativemethodsforlisteriadetectionthroughoutserrominascheeseripening
AT vanettimariacristinadantas performanceoftwoalternativemethodsforlisteriadetectionthroughoutserrominascheeseripening