Time resolved X-ray Dark-Field Tomography Revealing Water Transport in a Fresh Cement Sample

Grating-based X-ray dark-field tomography is a promising technique for biomedical and materials research. Even if the resolution of conventional X-ray tomography does not suffice to resolve relevant structures, the dark-field signal provides valuable information about the sub-pixel microstructural p...