Cargando…

The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis

PURPOSE: This study investigated the effects of bone density and crestal cortical bone thickness at the implant-placement site on micromotion (relative displacement between the implant and bone) and the peri-implant bone strain distribution under immediate-loading conditions. METHODS: A three-dimens...

Descripción completa

Detalles Bibliográficos
Autores principales: Sugiura, Tsutomu, Yamamoto, Kazuhiko, Horita, Satoshi, Murakami, Kazuhiro, Tsutsumi, Sadami, Kirita, Tadaaki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Periodontology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4928204/
https://www.ncbi.nlm.nih.gov/pubmed/27382504
http://dx.doi.org/10.5051/jpis.2016.46.3.152
_version_ 1782440398226980864
author Sugiura, Tsutomu
Yamamoto, Kazuhiko
Horita, Satoshi
Murakami, Kazuhiro
Tsutsumi, Sadami
Kirita, Tadaaki
author_facet Sugiura, Tsutomu
Yamamoto, Kazuhiko
Horita, Satoshi
Murakami, Kazuhiro
Tsutsumi, Sadami
Kirita, Tadaaki
author_sort Sugiura, Tsutomu
collection PubMed
description PURPOSE: This study investigated the effects of bone density and crestal cortical bone thickness at the implant-placement site on micromotion (relative displacement between the implant and bone) and the peri-implant bone strain distribution under immediate-loading conditions. METHODS: A three-dimensional finite element model of the posterior mandible with an implant was constructed. Various bone parameters were simulated, including low or high cancellous bone density, low or high crestal cortical bone density, and crestal cortical bone thicknesses ranging from 0.5 to 2.5 mm. Delayed- and immediate-loading conditions were simulated. A buccolingual oblique load of 200 N was applied to the top of the abutment. RESULTS: The maximum extent of micromotion was approximately 100 μm in the low-density cancellous bone models, whereas it was under 30 μm in the high-density cancellous bone models. Crestal cortical bone thickness significantly affected the maximum micromotion in the low-density cancellous bone models. The minimum principal strain in the peri-implant cortical bone was affected by the density of the crestal cortical bone and cancellous bone to the same degree for both delayed and immediate loading. In the low-density cancellous bone models under immediate loading, the minimum principal strain in the peri-implant cortical bone decreased with an increase in crestal cortical bone thickness. CONCLUSIONS: Cancellous bone density may be a critical factor for avoiding excessive micromotion in immediately loaded implants. Crestal cortical bone thickness significantly affected the maximum extent of micromotion and peri-implant bone strain in simulations of low-density cancellous bone under immediate loading.
format Online
Article
Text
id pubmed-4928204
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Korean Academy of Periodontology
record_format MEDLINE/PubMed
spelling pubmed-49282042016-07-05 The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis Sugiura, Tsutomu Yamamoto, Kazuhiko Horita, Satoshi Murakami, Kazuhiro Tsutsumi, Sadami Kirita, Tadaaki J Periodontal Implant Sci Research Article PURPOSE: This study investigated the effects of bone density and crestal cortical bone thickness at the implant-placement site on micromotion (relative displacement between the implant and bone) and the peri-implant bone strain distribution under immediate-loading conditions. METHODS: A three-dimensional finite element model of the posterior mandible with an implant was constructed. Various bone parameters were simulated, including low or high cancellous bone density, low or high crestal cortical bone density, and crestal cortical bone thicknesses ranging from 0.5 to 2.5 mm. Delayed- and immediate-loading conditions were simulated. A buccolingual oblique load of 200 N was applied to the top of the abutment. RESULTS: The maximum extent of micromotion was approximately 100 μm in the low-density cancellous bone models, whereas it was under 30 μm in the high-density cancellous bone models. Crestal cortical bone thickness significantly affected the maximum micromotion in the low-density cancellous bone models. The minimum principal strain in the peri-implant cortical bone was affected by the density of the crestal cortical bone and cancellous bone to the same degree for both delayed and immediate loading. In the low-density cancellous bone models under immediate loading, the minimum principal strain in the peri-implant cortical bone decreased with an increase in crestal cortical bone thickness. CONCLUSIONS: Cancellous bone density may be a critical factor for avoiding excessive micromotion in immediately loaded implants. Crestal cortical bone thickness significantly affected the maximum extent of micromotion and peri-implant bone strain in simulations of low-density cancellous bone under immediate loading. Korean Academy of Periodontology 2016-06 2016-06-28 /pmc/articles/PMC4928204/ /pubmed/27382504 http://dx.doi.org/10.5051/jpis.2016.46.3.152 Text en Copyright © 2016 Korean Academy of Periodontology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/).
spellingShingle Research Article
Sugiura, Tsutomu
Yamamoto, Kazuhiko
Horita, Satoshi
Murakami, Kazuhiro
Tsutsumi, Sadami
Kirita, Tadaaki
The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis
title The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis
title_full The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis
title_fullStr The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis
title_full_unstemmed The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis
title_short The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis
title_sort effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4928204/
https://www.ncbi.nlm.nih.gov/pubmed/27382504
http://dx.doi.org/10.5051/jpis.2016.46.3.152
work_keys_str_mv AT sugiuratsutomu theeffectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis
AT yamamotokazuhiko theeffectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis
AT horitasatoshi theeffectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis
AT murakamikazuhiro theeffectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis
AT tsutsumisadami theeffectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis
AT kiritatadaaki theeffectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis
AT sugiuratsutomu effectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis
AT yamamotokazuhiko effectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis
AT horitasatoshi effectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis
AT murakamikazuhiro effectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis
AT tsutsumisadami effectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis
AT kiritatadaaki effectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis