Cargando…
The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis
PURPOSE: This study investigated the effects of bone density and crestal cortical bone thickness at the implant-placement site on micromotion (relative displacement between the implant and bone) and the peri-implant bone strain distribution under immediate-loading conditions. METHODS: A three-dimens...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Periodontology
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4928204/ https://www.ncbi.nlm.nih.gov/pubmed/27382504 http://dx.doi.org/10.5051/jpis.2016.46.3.152 |
_version_ | 1782440398226980864 |
---|---|
author | Sugiura, Tsutomu Yamamoto, Kazuhiko Horita, Satoshi Murakami, Kazuhiro Tsutsumi, Sadami Kirita, Tadaaki |
author_facet | Sugiura, Tsutomu Yamamoto, Kazuhiko Horita, Satoshi Murakami, Kazuhiro Tsutsumi, Sadami Kirita, Tadaaki |
author_sort | Sugiura, Tsutomu |
collection | PubMed |
description | PURPOSE: This study investigated the effects of bone density and crestal cortical bone thickness at the implant-placement site on micromotion (relative displacement between the implant and bone) and the peri-implant bone strain distribution under immediate-loading conditions. METHODS: A three-dimensional finite element model of the posterior mandible with an implant was constructed. Various bone parameters were simulated, including low or high cancellous bone density, low or high crestal cortical bone density, and crestal cortical bone thicknesses ranging from 0.5 to 2.5 mm. Delayed- and immediate-loading conditions were simulated. A buccolingual oblique load of 200 N was applied to the top of the abutment. RESULTS: The maximum extent of micromotion was approximately 100 μm in the low-density cancellous bone models, whereas it was under 30 μm in the high-density cancellous bone models. Crestal cortical bone thickness significantly affected the maximum micromotion in the low-density cancellous bone models. The minimum principal strain in the peri-implant cortical bone was affected by the density of the crestal cortical bone and cancellous bone to the same degree for both delayed and immediate loading. In the low-density cancellous bone models under immediate loading, the minimum principal strain in the peri-implant cortical bone decreased with an increase in crestal cortical bone thickness. CONCLUSIONS: Cancellous bone density may be a critical factor for avoiding excessive micromotion in immediately loaded implants. Crestal cortical bone thickness significantly affected the maximum extent of micromotion and peri-implant bone strain in simulations of low-density cancellous bone under immediate loading. |
format | Online Article Text |
id | pubmed-4928204 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Korean Academy of Periodontology |
record_format | MEDLINE/PubMed |
spelling | pubmed-49282042016-07-05 The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis Sugiura, Tsutomu Yamamoto, Kazuhiko Horita, Satoshi Murakami, Kazuhiro Tsutsumi, Sadami Kirita, Tadaaki J Periodontal Implant Sci Research Article PURPOSE: This study investigated the effects of bone density and crestal cortical bone thickness at the implant-placement site on micromotion (relative displacement between the implant and bone) and the peri-implant bone strain distribution under immediate-loading conditions. METHODS: A three-dimensional finite element model of the posterior mandible with an implant was constructed. Various bone parameters were simulated, including low or high cancellous bone density, low or high crestal cortical bone density, and crestal cortical bone thicknesses ranging from 0.5 to 2.5 mm. Delayed- and immediate-loading conditions were simulated. A buccolingual oblique load of 200 N was applied to the top of the abutment. RESULTS: The maximum extent of micromotion was approximately 100 μm in the low-density cancellous bone models, whereas it was under 30 μm in the high-density cancellous bone models. Crestal cortical bone thickness significantly affected the maximum micromotion in the low-density cancellous bone models. The minimum principal strain in the peri-implant cortical bone was affected by the density of the crestal cortical bone and cancellous bone to the same degree for both delayed and immediate loading. In the low-density cancellous bone models under immediate loading, the minimum principal strain in the peri-implant cortical bone decreased with an increase in crestal cortical bone thickness. CONCLUSIONS: Cancellous bone density may be a critical factor for avoiding excessive micromotion in immediately loaded implants. Crestal cortical bone thickness significantly affected the maximum extent of micromotion and peri-implant bone strain in simulations of low-density cancellous bone under immediate loading. Korean Academy of Periodontology 2016-06 2016-06-28 /pmc/articles/PMC4928204/ /pubmed/27382504 http://dx.doi.org/10.5051/jpis.2016.46.3.152 Text en Copyright © 2016 Korean Academy of Periodontology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/). |
spellingShingle | Research Article Sugiura, Tsutomu Yamamoto, Kazuhiko Horita, Satoshi Murakami, Kazuhiro Tsutsumi, Sadami Kirita, Tadaaki The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis |
title | The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis |
title_full | The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis |
title_fullStr | The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis |
title_full_unstemmed | The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis |
title_short | The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis |
title_sort | effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4928204/ https://www.ncbi.nlm.nih.gov/pubmed/27382504 http://dx.doi.org/10.5051/jpis.2016.46.3.152 |
work_keys_str_mv | AT sugiuratsutomu theeffectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis AT yamamotokazuhiko theeffectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis AT horitasatoshi theeffectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis AT murakamikazuhiro theeffectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis AT tsutsumisadami theeffectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis AT kiritatadaaki theeffectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis AT sugiuratsutomu effectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis AT yamamotokazuhiko effectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis AT horitasatoshi effectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis AT murakamikazuhiro effectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis AT tsutsumisadami effectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis AT kiritatadaaki effectsofbonedensityandcrestalcorticalbonethicknessonmicromotionandperiimplantbonestraindistributioninanimmediatelyloadedimplantanonlinearfiniteelementanalysis |