Cargando…

Proposed New Electrolytic Conductivity Primary Standards for KCl Solutions

An absolute determination of aqueous electrolytic conductivity has been made for 0.01 molal (m) and 0.1 m potassium cliloride solutions, over the temperature range of 0 to 50 °C in 5 degree intervals. A cell with a removable center section of accurately known length and area was used for the measure...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Y. C., Koch, W. F., Pratt, K. W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1991
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4930028/
https://www.ncbi.nlm.nih.gov/pubmed/28184109
http://dx.doi.org/10.6028/jres.096.008

Ejemplares similares