Cargando…
Validation of an automated assay for the measurement of cupric reducing antioxidant capacity in serum of dogs
BACKGROUND: The objective of the present study was to optimize and validate an automated method to assess the total antioxidant capacity (TAC) in serum of dogs using the cupric reducing antioxidant capacity (CUPRAC) methodology (TAC(c)) with bathocuproinedisulfonic acid disodium salt as chelating ag...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4930603/ https://www.ncbi.nlm.nih.gov/pubmed/27370026 http://dx.doi.org/10.1186/s12917-016-0760-2 |
_version_ | 1782440769350533120 |
---|---|
author | Rubio, Camila Peres Tvarijonaviciute, Asta Martinez-Subiela, Silvia Hernández-Ruiz, Josefa Cerón, José Joaquin |
author_facet | Rubio, Camila Peres Tvarijonaviciute, Asta Martinez-Subiela, Silvia Hernández-Ruiz, Josefa Cerón, José Joaquin |
author_sort | Rubio, Camila Peres |
collection | PubMed |
description | BACKGROUND: The objective of the present study was to optimize and validate an automated method to assess the total antioxidant capacity (TAC) in serum of dogs using the cupric reducing antioxidant capacity (CUPRAC) methodology (TAC(c)) with bathocuproinedisulfonic acid disodium salt as chelating agent, evaluating also possible variations due to the use of two different automated analyzers. The method is based on the reduction of Cu(2+) into Cu(1+) by the action of the non-enzymatic antioxidants that are present in the sample. RESULTS: Imprecision was low in both apparatus utilized, and the results were linear across serial Trolox and canine serum samples dilutions. Lipids did not interfere with the assay; however, hemolysis increased the TAC(c) concentrations. When TAC(c) concentrations were determined in ten healthy (control) dogs and in twelve dogs with inflammatory bowel disease (IBD), dogs with IBD had lower TAC(c) concentrations when compared with the healthy dogs. CONCLUSIONS: The method validated in this paper is precise, simple, and fast and can be easily adapted to automated analyzers. |
format | Online Article Text |
id | pubmed-4930603 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-49306032016-07-03 Validation of an automated assay for the measurement of cupric reducing antioxidant capacity in serum of dogs Rubio, Camila Peres Tvarijonaviciute, Asta Martinez-Subiela, Silvia Hernández-Ruiz, Josefa Cerón, José Joaquin BMC Vet Res Methodology Article BACKGROUND: The objective of the present study was to optimize and validate an automated method to assess the total antioxidant capacity (TAC) in serum of dogs using the cupric reducing antioxidant capacity (CUPRAC) methodology (TAC(c)) with bathocuproinedisulfonic acid disodium salt as chelating agent, evaluating also possible variations due to the use of two different automated analyzers. The method is based on the reduction of Cu(2+) into Cu(1+) by the action of the non-enzymatic antioxidants that are present in the sample. RESULTS: Imprecision was low in both apparatus utilized, and the results were linear across serial Trolox and canine serum samples dilutions. Lipids did not interfere with the assay; however, hemolysis increased the TAC(c) concentrations. When TAC(c) concentrations were determined in ten healthy (control) dogs and in twelve dogs with inflammatory bowel disease (IBD), dogs with IBD had lower TAC(c) concentrations when compared with the healthy dogs. CONCLUSIONS: The method validated in this paper is precise, simple, and fast and can be easily adapted to automated analyzers. BioMed Central 2016-07-02 /pmc/articles/PMC4930603/ /pubmed/27370026 http://dx.doi.org/10.1186/s12917-016-0760-2 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Methodology Article Rubio, Camila Peres Tvarijonaviciute, Asta Martinez-Subiela, Silvia Hernández-Ruiz, Josefa Cerón, José Joaquin Validation of an automated assay for the measurement of cupric reducing antioxidant capacity in serum of dogs |
title | Validation of an automated assay for the measurement of cupric reducing antioxidant capacity in serum of dogs |
title_full | Validation of an automated assay for the measurement of cupric reducing antioxidant capacity in serum of dogs |
title_fullStr | Validation of an automated assay for the measurement of cupric reducing antioxidant capacity in serum of dogs |
title_full_unstemmed | Validation of an automated assay for the measurement of cupric reducing antioxidant capacity in serum of dogs |
title_short | Validation of an automated assay for the measurement of cupric reducing antioxidant capacity in serum of dogs |
title_sort | validation of an automated assay for the measurement of cupric reducing antioxidant capacity in serum of dogs |
topic | Methodology Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4930603/ https://www.ncbi.nlm.nih.gov/pubmed/27370026 http://dx.doi.org/10.1186/s12917-016-0760-2 |
work_keys_str_mv | AT rubiocamilaperes validationofanautomatedassayforthemeasurementofcupricreducingantioxidantcapacityinserumofdogs AT tvarijonaviciuteasta validationofanautomatedassayforthemeasurementofcupricreducingantioxidantcapacityinserumofdogs AT martinezsubielasilvia validationofanautomatedassayforthemeasurementofcupricreducingantioxidantcapacityinserumofdogs AT hernandezruizjosefa validationofanautomatedassayforthemeasurementofcupricreducingantioxidantcapacityinserumofdogs AT ceronjosejoaquin validationofanautomatedassayforthemeasurementofcupricreducingantioxidantcapacityinserumofdogs |