Cargando…
The modification of the thrombin generation test for the clinical assessment of dabigatran etexilate efficiency
A new oral anticoagulant, dabigatran etexilate (DE, a prodrug of direct thrombin inhibitor (DTI) dabigatran), has been used clinically to prevent thrombosis. The assessment of dabigatran efficiency is necessary in some clinical cases, such as renal insufficiency, risk of bleeding, and drug interacti...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4932519/ https://www.ncbi.nlm.nih.gov/pubmed/27377013 http://dx.doi.org/10.1038/srep29242 |
_version_ | 1782441070947205120 |
---|---|
author | Gribkova, Irina V. Lipets, Elena N. Rekhtina, Irina G. Bernakevich, Alex I. Ayusheev, Dorzho B. Ovsepyan, Ruzanna A. Ataullakhanov, Fazoil I. Sinauridze, Elena I. |
author_facet | Gribkova, Irina V. Lipets, Elena N. Rekhtina, Irina G. Bernakevich, Alex I. Ayusheev, Dorzho B. Ovsepyan, Ruzanna A. Ataullakhanov, Fazoil I. Sinauridze, Elena I. |
author_sort | Gribkova, Irina V. |
collection | PubMed |
description | A new oral anticoagulant, dabigatran etexilate (DE, a prodrug of direct thrombin inhibitor (DTI) dabigatran), has been used clinically to prevent thrombosis. The assessment of dabigatran efficiency is necessary in some clinical cases, such as renal insufficiency, risk of bleeding, and drug interactions. However, a specific thrombin generation test (TGT) that is one of the most informative and sensitive to anticoagulant therapy (calibrated automated thrombinography (САТ)) shows a paradoxical increase of test parameters, such as endogenous thrombin potential (ETP) and peak thrombin, in patients receiving DE. The paradoxical behaviour of ETP and peak thrombin in these patients in the presence of DTIs is mostly caused by a decrease in the activity of thrombin in the α(2)-macroglobulin-thrombin complex that is used as a calibrator in CAT. For a correct estimation of the TGT parameters in patient’s plasma containing DTIs we proposed to use our previously described alternative calibration method that is based on the measurement of the fluorescence signal of a well-known concentration of the reaction product (7-amino-4-methylcoumarin). In this study, the validity of such approach was demonstrated in an ex vivo study in patients with knee replacement and two special patients with multiple myeloma, who received DE for thrombosis prophylaxis. |
format | Online Article Text |
id | pubmed-4932519 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-49325192016-07-08 The modification of the thrombin generation test for the clinical assessment of dabigatran etexilate efficiency Gribkova, Irina V. Lipets, Elena N. Rekhtina, Irina G. Bernakevich, Alex I. Ayusheev, Dorzho B. Ovsepyan, Ruzanna A. Ataullakhanov, Fazoil I. Sinauridze, Elena I. Sci Rep Article A new oral anticoagulant, dabigatran etexilate (DE, a prodrug of direct thrombin inhibitor (DTI) dabigatran), has been used clinically to prevent thrombosis. The assessment of dabigatran efficiency is necessary in some clinical cases, such as renal insufficiency, risk of bleeding, and drug interactions. However, a specific thrombin generation test (TGT) that is one of the most informative and sensitive to anticoagulant therapy (calibrated automated thrombinography (САТ)) shows a paradoxical increase of test parameters, such as endogenous thrombin potential (ETP) and peak thrombin, in patients receiving DE. The paradoxical behaviour of ETP and peak thrombin in these patients in the presence of DTIs is mostly caused by a decrease in the activity of thrombin in the α(2)-macroglobulin-thrombin complex that is used as a calibrator in CAT. For a correct estimation of the TGT parameters in patient’s plasma containing DTIs we proposed to use our previously described alternative calibration method that is based on the measurement of the fluorescence signal of a well-known concentration of the reaction product (7-amino-4-methylcoumarin). In this study, the validity of such approach was demonstrated in an ex vivo study in patients with knee replacement and two special patients with multiple myeloma, who received DE for thrombosis prophylaxis. Nature Publishing Group 2016-07-05 /pmc/articles/PMC4932519/ /pubmed/27377013 http://dx.doi.org/10.1038/srep29242 Text en Copyright © 2016, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Gribkova, Irina V. Lipets, Elena N. Rekhtina, Irina G. Bernakevich, Alex I. Ayusheev, Dorzho B. Ovsepyan, Ruzanna A. Ataullakhanov, Fazoil I. Sinauridze, Elena I. The modification of the thrombin generation test for the clinical assessment of dabigatran etexilate efficiency |
title | The modification of the thrombin generation test for the clinical assessment of dabigatran etexilate efficiency |
title_full | The modification of the thrombin generation test for the clinical assessment of dabigatran etexilate efficiency |
title_fullStr | The modification of the thrombin generation test for the clinical assessment of dabigatran etexilate efficiency |
title_full_unstemmed | The modification of the thrombin generation test for the clinical assessment of dabigatran etexilate efficiency |
title_short | The modification of the thrombin generation test for the clinical assessment of dabigatran etexilate efficiency |
title_sort | modification of the thrombin generation test for the clinical assessment of dabigatran etexilate efficiency |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4932519/ https://www.ncbi.nlm.nih.gov/pubmed/27377013 http://dx.doi.org/10.1038/srep29242 |
work_keys_str_mv | AT gribkovairinav themodificationofthethrombingenerationtestfortheclinicalassessmentofdabigatranetexilateefficiency AT lipetselenan themodificationofthethrombingenerationtestfortheclinicalassessmentofdabigatranetexilateefficiency AT rekhtinairinag themodificationofthethrombingenerationtestfortheclinicalassessmentofdabigatranetexilateefficiency AT bernakevichalexi themodificationofthethrombingenerationtestfortheclinicalassessmentofdabigatranetexilateefficiency AT ayusheevdorzhob themodificationofthethrombingenerationtestfortheclinicalassessmentofdabigatranetexilateefficiency AT ovsepyanruzannaa themodificationofthethrombingenerationtestfortheclinicalassessmentofdabigatranetexilateefficiency AT ataullakhanovfazoili themodificationofthethrombingenerationtestfortheclinicalassessmentofdabigatranetexilateefficiency AT sinauridzeelenai themodificationofthethrombingenerationtestfortheclinicalassessmentofdabigatranetexilateefficiency AT gribkovairinav modificationofthethrombingenerationtestfortheclinicalassessmentofdabigatranetexilateefficiency AT lipetselenan modificationofthethrombingenerationtestfortheclinicalassessmentofdabigatranetexilateefficiency AT rekhtinairinag modificationofthethrombingenerationtestfortheclinicalassessmentofdabigatranetexilateefficiency AT bernakevichalexi modificationofthethrombingenerationtestfortheclinicalassessmentofdabigatranetexilateefficiency AT ayusheevdorzhob modificationofthethrombingenerationtestfortheclinicalassessmentofdabigatranetexilateefficiency AT ovsepyanruzannaa modificationofthethrombingenerationtestfortheclinicalassessmentofdabigatranetexilateefficiency AT ataullakhanovfazoili modificationofthethrombingenerationtestfortheclinicalassessmentofdabigatranetexilateefficiency AT sinauridzeelenai modificationofthethrombingenerationtestfortheclinicalassessmentofdabigatranetexilateefficiency |