Cargando…
In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography
Direct in vivo imaging of lymph flow is key to understanding lymphatic system function in normal and disease states. Optical microscopy techniques provide the resolution required for these measurements, but existing optical techniques for measuring lymph flow require complex protocols and provide li...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4932526/ https://www.ncbi.nlm.nih.gov/pubmed/27377852 http://dx.doi.org/10.1038/srep29035 |
_version_ | 1782441072534749184 |
---|---|
author | Blatter, Cedric Meijer, Eelco F. J. Nam, Ahhyun S. Jones, Dennis Bouma, Brett E. Padera, Timothy P. Vakoc, Benjamin J. |
author_facet | Blatter, Cedric Meijer, Eelco F. J. Nam, Ahhyun S. Jones, Dennis Bouma, Brett E. Padera, Timothy P. Vakoc, Benjamin J. |
author_sort | Blatter, Cedric |
collection | PubMed |
description | Direct in vivo imaging of lymph flow is key to understanding lymphatic system function in normal and disease states. Optical microscopy techniques provide the resolution required for these measurements, but existing optical techniques for measuring lymph flow require complex protocols and provide limited temporal resolution. Here, we describe a Doppler optical coherence tomography platform that allows direct, label-free quantification of lymph velocity and volumetric flow rates. We overcome the challenge of very low scattering by employing a Doppler algorithm that operates on low signal-to-noise measurements. We show that this technique can measure lymph velocity at sufficiently high temporal resolution to resolve the dynamic pulsatile flow in collecting lymphatic vessels. |
format | Online Article Text |
id | pubmed-4932526 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-49325262016-07-08 In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography Blatter, Cedric Meijer, Eelco F. J. Nam, Ahhyun S. Jones, Dennis Bouma, Brett E. Padera, Timothy P. Vakoc, Benjamin J. Sci Rep Article Direct in vivo imaging of lymph flow is key to understanding lymphatic system function in normal and disease states. Optical microscopy techniques provide the resolution required for these measurements, but existing optical techniques for measuring lymph flow require complex protocols and provide limited temporal resolution. Here, we describe a Doppler optical coherence tomography platform that allows direct, label-free quantification of lymph velocity and volumetric flow rates. We overcome the challenge of very low scattering by employing a Doppler algorithm that operates on low signal-to-noise measurements. We show that this technique can measure lymph velocity at sufficiently high temporal resolution to resolve the dynamic pulsatile flow in collecting lymphatic vessels. Nature Publishing Group 2016-07-05 /pmc/articles/PMC4932526/ /pubmed/27377852 http://dx.doi.org/10.1038/srep29035 Text en Copyright © 2016, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Blatter, Cedric Meijer, Eelco F. J. Nam, Ahhyun S. Jones, Dennis Bouma, Brett E. Padera, Timothy P. Vakoc, Benjamin J. In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography |
title | In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography |
title_full | In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography |
title_fullStr | In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography |
title_full_unstemmed | In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography |
title_short | In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography |
title_sort | in vivo label-free measurement of lymph flow velocity and volumetric flow rates using doppler optical coherence tomography |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4932526/ https://www.ncbi.nlm.nih.gov/pubmed/27377852 http://dx.doi.org/10.1038/srep29035 |
work_keys_str_mv | AT blattercedric invivolabelfreemeasurementoflymphflowvelocityandvolumetricflowratesusingdoppleropticalcoherencetomography AT meijereelcofj invivolabelfreemeasurementoflymphflowvelocityandvolumetricflowratesusingdoppleropticalcoherencetomography AT namahhyuns invivolabelfreemeasurementoflymphflowvelocityandvolumetricflowratesusingdoppleropticalcoherencetomography AT jonesdennis invivolabelfreemeasurementoflymphflowvelocityandvolumetricflowratesusingdoppleropticalcoherencetomography AT boumabrette invivolabelfreemeasurementoflymphflowvelocityandvolumetricflowratesusingdoppleropticalcoherencetomography AT paderatimothyp invivolabelfreemeasurementoflymphflowvelocityandvolumetricflowratesusingdoppleropticalcoherencetomography AT vakocbenjaminj invivolabelfreemeasurementoflymphflowvelocityandvolumetricflowratesusingdoppleropticalcoherencetomography |