Cargando…

In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography

Direct in vivo imaging of lymph flow is key to understanding lymphatic system function in normal and disease states. Optical microscopy techniques provide the resolution required for these measurements, but existing optical techniques for measuring lymph flow require complex protocols and provide li...

Descripción completa

Detalles Bibliográficos
Autores principales: Blatter, Cedric, Meijer, Eelco F. J., Nam, Ahhyun S., Jones, Dennis, Bouma, Brett E., Padera, Timothy P., Vakoc, Benjamin J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4932526/
https://www.ncbi.nlm.nih.gov/pubmed/27377852
http://dx.doi.org/10.1038/srep29035
_version_ 1782441072534749184
author Blatter, Cedric
Meijer, Eelco F. J.
Nam, Ahhyun S.
Jones, Dennis
Bouma, Brett E.
Padera, Timothy P.
Vakoc, Benjamin J.
author_facet Blatter, Cedric
Meijer, Eelco F. J.
Nam, Ahhyun S.
Jones, Dennis
Bouma, Brett E.
Padera, Timothy P.
Vakoc, Benjamin J.
author_sort Blatter, Cedric
collection PubMed
description Direct in vivo imaging of lymph flow is key to understanding lymphatic system function in normal and disease states. Optical microscopy techniques provide the resolution required for these measurements, but existing optical techniques for measuring lymph flow require complex protocols and provide limited temporal resolution. Here, we describe a Doppler optical coherence tomography platform that allows direct, label-free quantification of lymph velocity and volumetric flow rates. We overcome the challenge of very low scattering by employing a Doppler algorithm that operates on low signal-to-noise measurements. We show that this technique can measure lymph velocity at sufficiently high temporal resolution to resolve the dynamic pulsatile flow in collecting lymphatic vessels.
format Online
Article
Text
id pubmed-4932526
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-49325262016-07-08 In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography Blatter, Cedric Meijer, Eelco F. J. Nam, Ahhyun S. Jones, Dennis Bouma, Brett E. Padera, Timothy P. Vakoc, Benjamin J. Sci Rep Article Direct in vivo imaging of lymph flow is key to understanding lymphatic system function in normal and disease states. Optical microscopy techniques provide the resolution required for these measurements, but existing optical techniques for measuring lymph flow require complex protocols and provide limited temporal resolution. Here, we describe a Doppler optical coherence tomography platform that allows direct, label-free quantification of lymph velocity and volumetric flow rates. We overcome the challenge of very low scattering by employing a Doppler algorithm that operates on low signal-to-noise measurements. We show that this technique can measure lymph velocity at sufficiently high temporal resolution to resolve the dynamic pulsatile flow in collecting lymphatic vessels. Nature Publishing Group 2016-07-05 /pmc/articles/PMC4932526/ /pubmed/27377852 http://dx.doi.org/10.1038/srep29035 Text en Copyright © 2016, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Blatter, Cedric
Meijer, Eelco F. J.
Nam, Ahhyun S.
Jones, Dennis
Bouma, Brett E.
Padera, Timothy P.
Vakoc, Benjamin J.
In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography
title In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography
title_full In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography
title_fullStr In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography
title_full_unstemmed In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography
title_short In vivo label-free measurement of lymph flow velocity and volumetric flow rates using Doppler optical coherence tomography
title_sort in vivo label-free measurement of lymph flow velocity and volumetric flow rates using doppler optical coherence tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4932526/
https://www.ncbi.nlm.nih.gov/pubmed/27377852
http://dx.doi.org/10.1038/srep29035
work_keys_str_mv AT blattercedric invivolabelfreemeasurementoflymphflowvelocityandvolumetricflowratesusingdoppleropticalcoherencetomography
AT meijereelcofj invivolabelfreemeasurementoflymphflowvelocityandvolumetricflowratesusingdoppleropticalcoherencetomography
AT namahhyuns invivolabelfreemeasurementoflymphflowvelocityandvolumetricflowratesusingdoppleropticalcoherencetomography
AT jonesdennis invivolabelfreemeasurementoflymphflowvelocityandvolumetricflowratesusingdoppleropticalcoherencetomography
AT boumabrette invivolabelfreemeasurementoflymphflowvelocityandvolumetricflowratesusingdoppleropticalcoherencetomography
AT paderatimothyp invivolabelfreemeasurementoflymphflowvelocityandvolumetricflowratesusingdoppleropticalcoherencetomography
AT vakocbenjaminj invivolabelfreemeasurementoflymphflowvelocityandvolumetricflowratesusingdoppleropticalcoherencetomography