Cargando…

Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse

The radial artery pulse is one of the major diagnostic indices used clinically in both Eastern and Western medicine. One of the prominent methods for measuring the radial artery pulse is the piezoresistive sensor array. Independence among channels and an appropriate sensor arrangement are important...

Descripción completa

Detalles Bibliográficos
Autores principales: Jun, Min-Ho, Kim, Young-Min, Bae, Jang-Han, Jung, Chang Jin, Cho, Jung-Hee, Jeon, Young Ju
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4934194/
https://www.ncbi.nlm.nih.gov/pubmed/27240363
http://dx.doi.org/10.3390/s16060768
_version_ 1782441292076154880
author Jun, Min-Ho
Kim, Young-Min
Bae, Jang-Han
Jung, Chang Jin
Cho, Jung-Hee
Jeon, Young Ju
author_facet Jun, Min-Ho
Kim, Young-Min
Bae, Jang-Han
Jung, Chang Jin
Cho, Jung-Hee
Jeon, Young Ju
author_sort Jun, Min-Ho
collection PubMed
description The radial artery pulse is one of the major diagnostic indices used clinically in both Eastern and Western medicine. One of the prominent methods for measuring the radial artery pulse is the piezoresistive sensor array. Independence among channels and an appropriate sensor arrangement are important for effectively assessing the spatial-temporal information of the pulse. This study developed a circular-type seven-channel piezoresistive sensor array using face-down bonding (FDB) as one of the sensor combination methods. The three-layered housing structure that included independent pressure sensor units using the FDB method not only enabled elimination of the crosstalk among channels, but also allowed various array patterns to be created for effective pulse measurement. The sensors were arranged in a circular-type arrangement such that they could estimate the direction of the radial artery and precisely measure the pulse wave. The performance of the fabricated sensor array was validated by evaluating the sensor sensitivity per channel, and the possibility of estimating the blood vessel direction was demonstrated through a radial artery pulse simulator. We expect the proposed sensor to allow accurate extraction of the pulse indices for pulse diagnosis.
format Online
Article
Text
id pubmed-4934194
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-49341942016-07-06 Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse Jun, Min-Ho Kim, Young-Min Bae, Jang-Han Jung, Chang Jin Cho, Jung-Hee Jeon, Young Ju Sensors (Basel) Article The radial artery pulse is one of the major diagnostic indices used clinically in both Eastern and Western medicine. One of the prominent methods for measuring the radial artery pulse is the piezoresistive sensor array. Independence among channels and an appropriate sensor arrangement are important for effectively assessing the spatial-temporal information of the pulse. This study developed a circular-type seven-channel piezoresistive sensor array using face-down bonding (FDB) as one of the sensor combination methods. The three-layered housing structure that included independent pressure sensor units using the FDB method not only enabled elimination of the crosstalk among channels, but also allowed various array patterns to be created for effective pulse measurement. The sensors were arranged in a circular-type arrangement such that they could estimate the direction of the radial artery and precisely measure the pulse wave. The performance of the fabricated sensor array was validated by evaluating the sensor sensitivity per channel, and the possibility of estimating the blood vessel direction was demonstrated through a radial artery pulse simulator. We expect the proposed sensor to allow accurate extraction of the pulse indices for pulse diagnosis. MDPI 2016-05-26 /pmc/articles/PMC4934194/ /pubmed/27240363 http://dx.doi.org/10.3390/s16060768 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jun, Min-Ho
Kim, Young-Min
Bae, Jang-Han
Jung, Chang Jin
Cho, Jung-Hee
Jeon, Young Ju
Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse
title Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse
title_full Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse
title_fullStr Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse
title_full_unstemmed Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse
title_short Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse
title_sort development of a tonometric sensor with a decoupled circular array for precisely measuring radial artery pulse
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4934194/
https://www.ncbi.nlm.nih.gov/pubmed/27240363
http://dx.doi.org/10.3390/s16060768
work_keys_str_mv AT junminho developmentofatonometricsensorwithadecoupledcirculararrayforpreciselymeasuringradialarterypulse
AT kimyoungmin developmentofatonometricsensorwithadecoupledcirculararrayforpreciselymeasuringradialarterypulse
AT baejanghan developmentofatonometricsensorwithadecoupledcirculararrayforpreciselymeasuringradialarterypulse
AT jungchangjin developmentofatonometricsensorwithadecoupledcirculararrayforpreciselymeasuringradialarterypulse
AT chojunghee developmentofatonometricsensorwithadecoupledcirculararrayforpreciselymeasuringradialarterypulse
AT jeonyoungju developmentofatonometricsensorwithadecoupledcirculararrayforpreciselymeasuringradialarterypulse