Cargando…
Novel Wearable Device for Blood Leakage Detection during Hemodialysis Using an Array Sensing Patch
Hemodialysis (HD) is a clinical treatment that requires the puncturing of the body surface. However, needle dislodgement can cause a high risk of blood leakage and can be fatal to patients. Previous studies proposed several devices for blood leakage detection using optical or electrical techniques....
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4934275/ https://www.ncbi.nlm.nih.gov/pubmed/27294927 http://dx.doi.org/10.3390/s16060849 |
_version_ | 1782441310505926656 |
---|---|
author | Du, Yi-Chun Lim, Bee-Yen Ciou, Wei-Siang Wu, Ming-Jui |
author_facet | Du, Yi-Chun Lim, Bee-Yen Ciou, Wei-Siang Wu, Ming-Jui |
author_sort | Du, Yi-Chun |
collection | PubMed |
description | Hemodialysis (HD) is a clinical treatment that requires the puncturing of the body surface. However, needle dislodgement can cause a high risk of blood leakage and can be fatal to patients. Previous studies proposed several devices for blood leakage detection using optical or electrical techniques. Nonetheless, these methods used single-point detection and the design was not suitable for multi-bed monitoring. This study proposed a novel wearable device for blood leakage monitoring during HD using an array sensing patch. The array sensing patch combined with a mapping circuit and a wireless module could measure and transmit risk levels. The different risk levels could improve the working process of healthcare workers, and enhance their work efficiency and reduce inconvenience due to false alarms. Experimental results showed that each point of the sensing array could detect up to 0.1 mL of blood leakage and the array sensing patch supports a risk level monitoring system up to 8 h to alert healthcare personnel of pertinent danger to the patients. |
format | Online Article Text |
id | pubmed-4934275 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-49342752016-07-06 Novel Wearable Device for Blood Leakage Detection during Hemodialysis Using an Array Sensing Patch Du, Yi-Chun Lim, Bee-Yen Ciou, Wei-Siang Wu, Ming-Jui Sensors (Basel) Article Hemodialysis (HD) is a clinical treatment that requires the puncturing of the body surface. However, needle dislodgement can cause a high risk of blood leakage and can be fatal to patients. Previous studies proposed several devices for blood leakage detection using optical or electrical techniques. Nonetheless, these methods used single-point detection and the design was not suitable for multi-bed monitoring. This study proposed a novel wearable device for blood leakage monitoring during HD using an array sensing patch. The array sensing patch combined with a mapping circuit and a wireless module could measure and transmit risk levels. The different risk levels could improve the working process of healthcare workers, and enhance their work efficiency and reduce inconvenience due to false alarms. Experimental results showed that each point of the sensing array could detect up to 0.1 mL of blood leakage and the array sensing patch supports a risk level monitoring system up to 8 h to alert healthcare personnel of pertinent danger to the patients. MDPI 2016-06-09 /pmc/articles/PMC4934275/ /pubmed/27294927 http://dx.doi.org/10.3390/s16060849 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Du, Yi-Chun Lim, Bee-Yen Ciou, Wei-Siang Wu, Ming-Jui Novel Wearable Device for Blood Leakage Detection during Hemodialysis Using an Array Sensing Patch |
title | Novel Wearable Device for Blood Leakage Detection during Hemodialysis Using an Array Sensing Patch |
title_full | Novel Wearable Device for Blood Leakage Detection during Hemodialysis Using an Array Sensing Patch |
title_fullStr | Novel Wearable Device for Blood Leakage Detection during Hemodialysis Using an Array Sensing Patch |
title_full_unstemmed | Novel Wearable Device for Blood Leakage Detection during Hemodialysis Using an Array Sensing Patch |
title_short | Novel Wearable Device for Blood Leakage Detection during Hemodialysis Using an Array Sensing Patch |
title_sort | novel wearable device for blood leakage detection during hemodialysis using an array sensing patch |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4934275/ https://www.ncbi.nlm.nih.gov/pubmed/27294927 http://dx.doi.org/10.3390/s16060849 |
work_keys_str_mv | AT duyichun novelwearabledeviceforbloodleakagedetectionduringhemodialysisusinganarraysensingpatch AT limbeeyen novelwearabledeviceforbloodleakagedetectionduringhemodialysisusinganarraysensingpatch AT ciouweisiang novelwearabledeviceforbloodleakagedetectionduringhemodialysisusinganarraysensingpatch AT wumingjui novelwearabledeviceforbloodleakagedetectionduringhemodialysisusinganarraysensingpatch |