Cargando…
Design and Performance Analysis of an Intrinsically Safe Ultrasonic Ranging Sensor
In flammable or explosive environments, an ultrasonic sensor for distance measurement poses an important engineering safety challenge, because the driving circuit uses an intermediate frequency transformer as an impedance transformation element, in which the produced heat or spark is available for i...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4934293/ https://www.ncbi.nlm.nih.gov/pubmed/27304958 http://dx.doi.org/10.3390/s16060867 |
_version_ | 1782441314682404864 |
---|---|
author | Zhang, Hongjuan Wang, Yu Zhang, Xu Wang, Dong Jin, Baoquan |
author_facet | Zhang, Hongjuan Wang, Yu Zhang, Xu Wang, Dong Jin, Baoquan |
author_sort | Zhang, Hongjuan |
collection | PubMed |
description | In flammable or explosive environments, an ultrasonic sensor for distance measurement poses an important engineering safety challenge, because the driving circuit uses an intermediate frequency transformer as an impedance transformation element, in which the produced heat or spark is available for ignition. In this paper, an intrinsically safe ultrasonic ranging sensor is designed and implemented. The waterproof piezoelectric transducer with integrated transceiver is chosen as an energy transducing element. Then a novel transducer driving circuit is designed based on an impedance matching method considering safety spark parameters to replace an intermediate frequency transformer. Then, an energy limiting circuit is developed to achieve dual levels of over-voltage and over-current protection. The detail calculation and evaluation are executed and the electrical characteristics are analyzed to verify the intrinsic safety of the driving circuit. Finally, an experimental platform of the ultrasonic ranging sensor system is constructed, which involves short-circuit protection. Experimental results show that the proposed ultrasonic ranging sensor is excellent in both ranging performance and intrinsic safety. |
format | Online Article Text |
id | pubmed-4934293 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-49342932016-07-06 Design and Performance Analysis of an Intrinsically Safe Ultrasonic Ranging Sensor Zhang, Hongjuan Wang, Yu Zhang, Xu Wang, Dong Jin, Baoquan Sensors (Basel) Article In flammable or explosive environments, an ultrasonic sensor for distance measurement poses an important engineering safety challenge, because the driving circuit uses an intermediate frequency transformer as an impedance transformation element, in which the produced heat or spark is available for ignition. In this paper, an intrinsically safe ultrasonic ranging sensor is designed and implemented. The waterproof piezoelectric transducer with integrated transceiver is chosen as an energy transducing element. Then a novel transducer driving circuit is designed based on an impedance matching method considering safety spark parameters to replace an intermediate frequency transformer. Then, an energy limiting circuit is developed to achieve dual levels of over-voltage and over-current protection. The detail calculation and evaluation are executed and the electrical characteristics are analyzed to verify the intrinsic safety of the driving circuit. Finally, an experimental platform of the ultrasonic ranging sensor system is constructed, which involves short-circuit protection. Experimental results show that the proposed ultrasonic ranging sensor is excellent in both ranging performance and intrinsic safety. MDPI 2016-06-13 /pmc/articles/PMC4934293/ /pubmed/27304958 http://dx.doi.org/10.3390/s16060867 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhang, Hongjuan Wang, Yu Zhang, Xu Wang, Dong Jin, Baoquan Design and Performance Analysis of an Intrinsically Safe Ultrasonic Ranging Sensor |
title | Design and Performance Analysis of an Intrinsically Safe Ultrasonic Ranging Sensor |
title_full | Design and Performance Analysis of an Intrinsically Safe Ultrasonic Ranging Sensor |
title_fullStr | Design and Performance Analysis of an Intrinsically Safe Ultrasonic Ranging Sensor |
title_full_unstemmed | Design and Performance Analysis of an Intrinsically Safe Ultrasonic Ranging Sensor |
title_short | Design and Performance Analysis of an Intrinsically Safe Ultrasonic Ranging Sensor |
title_sort | design and performance analysis of an intrinsically safe ultrasonic ranging sensor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4934293/ https://www.ncbi.nlm.nih.gov/pubmed/27304958 http://dx.doi.org/10.3390/s16060867 |
work_keys_str_mv | AT zhanghongjuan designandperformanceanalysisofanintrinsicallysafeultrasonicrangingsensor AT wangyu designandperformanceanalysisofanintrinsicallysafeultrasonicrangingsensor AT zhangxu designandperformanceanalysisofanintrinsicallysafeultrasonicrangingsensor AT wangdong designandperformanceanalysisofanintrinsicallysafeultrasonicrangingsensor AT jinbaoquan designandperformanceanalysisofanintrinsicallysafeultrasonicrangingsensor |