Cargando…
Comprehensive MR Urography Protocol: Equally Good Diagnostic Performance and Enhanced Visibility of the Upper Urinary Tract Compared to Triple-Phase CT Urography
OBJECTIVES: To prospectively compare the diagnostic performance and the visualization of the upper urinary tract (UUT) using a comprehensive 3.0T- magnetic resonance urography (MRU) protocol versus triple-phase computed tomography urography (CTU). METHODS: During the study period (January-2014 throu...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4934766/ https://www.ncbi.nlm.nih.gov/pubmed/27384417 http://dx.doi.org/10.1371/journal.pone.0158673 |
_version_ | 1782441384913928192 |
---|---|
author | Sudah, Mazen Masarwah, Amro Kainulainen, Sakari Pitkänen, Marja Matikka, Hanna Dabravolskaite, Vaiva Aaltomaa, Sirpa Vanninen, Ritva |
author_facet | Sudah, Mazen Masarwah, Amro Kainulainen, Sakari Pitkänen, Marja Matikka, Hanna Dabravolskaite, Vaiva Aaltomaa, Sirpa Vanninen, Ritva |
author_sort | Sudah, Mazen |
collection | PubMed |
description | OBJECTIVES: To prospectively compare the diagnostic performance and the visualization of the upper urinary tract (UUT) using a comprehensive 3.0T- magnetic resonance urography (MRU) protocol versus triple-phase computed tomography urography (CTU). METHODS: During the study period (January-2014 through December-2015), all consecutive patients in our tertiary university hospital scheduled by a urologist for CTU to exclude UUT malignancy were invited to participate. Diagnostic performance and visualization scores of 3.0T-MRU were compared to CTU using Wilcoxon matched-pairs test. RESULTS: Twenty patients (39 UUT excreting units) were evaluated. 3.0T-MRU and CTU achieved equal diagnostic performances. The benign etiology of seven UUT obstructions was clarified equally with both methods. Another two urinary tract malignant tumors and one benign extraurinary tumor were detected and confirmed. Diagnostic visualization was slightly better in the intrarenal cavity areas with CTU but worsened towards distal ureter. MRU showed consistently slightly better visualization of the ureter. In the comparison, full 100% visualizations were detected in all areas in 93.6% (with 3.0T-MRU) and 87.2% (with CTU) and >75% visualization in 100% (3.0T-MRU) and 93.6% (CTU). Mean CTU effective radiation dose was 9.2 mSv. CONCLUSIONS: Comprehensive 3.0T-MRU is an accurate imaging modality achieving comparable performance with CTU; since it does not entail exposure to radiation, it has the potential to become the primary investigation technique in selected patients. TRIAL REGISTRATION: ClinicalTrials.gov NCT02606513 |
format | Online Article Text |
id | pubmed-4934766 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-49347662016-07-18 Comprehensive MR Urography Protocol: Equally Good Diagnostic Performance and Enhanced Visibility of the Upper Urinary Tract Compared to Triple-Phase CT Urography Sudah, Mazen Masarwah, Amro Kainulainen, Sakari Pitkänen, Marja Matikka, Hanna Dabravolskaite, Vaiva Aaltomaa, Sirpa Vanninen, Ritva PLoS One Research Article OBJECTIVES: To prospectively compare the diagnostic performance and the visualization of the upper urinary tract (UUT) using a comprehensive 3.0T- magnetic resonance urography (MRU) protocol versus triple-phase computed tomography urography (CTU). METHODS: During the study period (January-2014 through December-2015), all consecutive patients in our tertiary university hospital scheduled by a urologist for CTU to exclude UUT malignancy were invited to participate. Diagnostic performance and visualization scores of 3.0T-MRU were compared to CTU using Wilcoxon matched-pairs test. RESULTS: Twenty patients (39 UUT excreting units) were evaluated. 3.0T-MRU and CTU achieved equal diagnostic performances. The benign etiology of seven UUT obstructions was clarified equally with both methods. Another two urinary tract malignant tumors and one benign extraurinary tumor were detected and confirmed. Diagnostic visualization was slightly better in the intrarenal cavity areas with CTU but worsened towards distal ureter. MRU showed consistently slightly better visualization of the ureter. In the comparison, full 100% visualizations were detected in all areas in 93.6% (with 3.0T-MRU) and 87.2% (with CTU) and >75% visualization in 100% (3.0T-MRU) and 93.6% (CTU). Mean CTU effective radiation dose was 9.2 mSv. CONCLUSIONS: Comprehensive 3.0T-MRU is an accurate imaging modality achieving comparable performance with CTU; since it does not entail exposure to radiation, it has the potential to become the primary investigation technique in selected patients. TRIAL REGISTRATION: ClinicalTrials.gov NCT02606513 Public Library of Science 2016-07-06 /pmc/articles/PMC4934766/ /pubmed/27384417 http://dx.doi.org/10.1371/journal.pone.0158673 Text en © 2016 Sudah et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Sudah, Mazen Masarwah, Amro Kainulainen, Sakari Pitkänen, Marja Matikka, Hanna Dabravolskaite, Vaiva Aaltomaa, Sirpa Vanninen, Ritva Comprehensive MR Urography Protocol: Equally Good Diagnostic Performance and Enhanced Visibility of the Upper Urinary Tract Compared to Triple-Phase CT Urography |
title | Comprehensive MR Urography Protocol: Equally Good Diagnostic Performance and Enhanced Visibility of the Upper Urinary Tract Compared to Triple-Phase CT Urography |
title_full | Comprehensive MR Urography Protocol: Equally Good Diagnostic Performance and Enhanced Visibility of the Upper Urinary Tract Compared to Triple-Phase CT Urography |
title_fullStr | Comprehensive MR Urography Protocol: Equally Good Diagnostic Performance and Enhanced Visibility of the Upper Urinary Tract Compared to Triple-Phase CT Urography |
title_full_unstemmed | Comprehensive MR Urography Protocol: Equally Good Diagnostic Performance and Enhanced Visibility of the Upper Urinary Tract Compared to Triple-Phase CT Urography |
title_short | Comprehensive MR Urography Protocol: Equally Good Diagnostic Performance and Enhanced Visibility of the Upper Urinary Tract Compared to Triple-Phase CT Urography |
title_sort | comprehensive mr urography protocol: equally good diagnostic performance and enhanced visibility of the upper urinary tract compared to triple-phase ct urography |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4934766/ https://www.ncbi.nlm.nih.gov/pubmed/27384417 http://dx.doi.org/10.1371/journal.pone.0158673 |
work_keys_str_mv | AT sudahmazen comprehensivemrurographyprotocolequallygooddiagnosticperformanceandenhancedvisibilityoftheupperurinarytractcomparedtotriplephasecturography AT masarwahamro comprehensivemrurographyprotocolequallygooddiagnosticperformanceandenhancedvisibilityoftheupperurinarytractcomparedtotriplephasecturography AT kainulainensakari comprehensivemrurographyprotocolequallygooddiagnosticperformanceandenhancedvisibilityoftheupperurinarytractcomparedtotriplephasecturography AT pitkanenmarja comprehensivemrurographyprotocolequallygooddiagnosticperformanceandenhancedvisibilityoftheupperurinarytractcomparedtotriplephasecturography AT matikkahanna comprehensivemrurographyprotocolequallygooddiagnosticperformanceandenhancedvisibilityoftheupperurinarytractcomparedtotriplephasecturography AT dabravolskaitevaiva comprehensivemrurographyprotocolequallygooddiagnosticperformanceandenhancedvisibilityoftheupperurinarytractcomparedtotriplephasecturography AT aaltomaasirpa comprehensivemrurographyprotocolequallygooddiagnosticperformanceandenhancedvisibilityoftheupperurinarytractcomparedtotriplephasecturography AT vanninenritva comprehensivemrurographyprotocolequallygooddiagnosticperformanceandenhancedvisibilityoftheupperurinarytractcomparedtotriplephasecturography |