Acoustic Cavitation Enhances Focused Ultrasound Ablation with Phase-Shift Inorganic Perfluorohexane Nanoemulsions: An In Vitro Study Using a Clinical Device
Purpose. To investigate whether acoustic cavitation could increase the evaporation of a phase-shift inorganic perfluorohexane (PFH) nanoemulsion and enhance high intensity focused ultrasound (HIFU) ablation. Materials and Methods. PFH was encapsulated by mesoporous silica nanocapsule (MSNC) to form...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4935909/ https://www.ncbi.nlm.nih.gov/pubmed/27419138 http://dx.doi.org/10.1155/2016/7936902 |
_version_ | 1782441480944615424 |
---|---|
author | Zhao, Lu-Yan Zou, Jian-Zhong Chen, Zong-Gui Liu, Shan Jiao, Jiao Wu, Feng |
author_facet | Zhao, Lu-Yan Zou, Jian-Zhong Chen, Zong-Gui Liu, Shan Jiao, Jiao Wu, Feng |
author_sort | Zhao, Lu-Yan |
collection | PubMed |
description | Purpose. To investigate whether acoustic cavitation could increase the evaporation of a phase-shift inorganic perfluorohexane (PFH) nanoemulsion and enhance high intensity focused ultrasound (HIFU) ablation. Materials and Methods. PFH was encapsulated by mesoporous silica nanocapsule (MSNC) to form a nanometer-sized droplet (MSNC-PFH). It was added to a tissue-mimicking phantom, whereas phosphate buffered saline (PBS) was added as a control (PBS-control). HIFU (P (ac) = 150 W, t = 5/10 s) exposures were performed in both phantoms with various duty cycles (DC). US images, temperature, and cavitation emissions were recorded during HIFU exposure. HIFU-induced lesions were measured and calculated. Results. Compared to PBS-control, MSNC-PFH nanoemulsion could significantly increase the volume of HIFU-induced lesion (P < 0.01). Peak temperatures were 78.16 ± 5.64°C at a DC of 100%, 70.17 ± 6.43°C at 10%, 53.17 ± 4.54°C at 5%, and 42.00 ± 5.55°C at 2%, respectively. Inertial cavitation was much stronger in the pulsed-HIFU than that in the continuous-wave HIFU exposure. Compared to 100%-DC exposure, the mean volume of lesion induced by 5 s exposure at 10%-DC was significantly larger, but smaller at 2%-DC. Conclusions. MSNC-PFH nanoemulsion can significantly enhance HIFU ablation. Appropriate pulsed-HIFU exposure could significantly increase the volume of lesion and reduce total US energy required for HIFU ablation. |
format | Online Article Text |
id | pubmed-4935909 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-49359092016-07-14 Acoustic Cavitation Enhances Focused Ultrasound Ablation with Phase-Shift Inorganic Perfluorohexane Nanoemulsions: An In Vitro Study Using a Clinical Device Zhao, Lu-Yan Zou, Jian-Zhong Chen, Zong-Gui Liu, Shan Jiao, Jiao Wu, Feng Biomed Res Int Research Article Purpose. To investigate whether acoustic cavitation could increase the evaporation of a phase-shift inorganic perfluorohexane (PFH) nanoemulsion and enhance high intensity focused ultrasound (HIFU) ablation. Materials and Methods. PFH was encapsulated by mesoporous silica nanocapsule (MSNC) to form a nanometer-sized droplet (MSNC-PFH). It was added to a tissue-mimicking phantom, whereas phosphate buffered saline (PBS) was added as a control (PBS-control). HIFU (P (ac) = 150 W, t = 5/10 s) exposures were performed in both phantoms with various duty cycles (DC). US images, temperature, and cavitation emissions were recorded during HIFU exposure. HIFU-induced lesions were measured and calculated. Results. Compared to PBS-control, MSNC-PFH nanoemulsion could significantly increase the volume of HIFU-induced lesion (P < 0.01). Peak temperatures were 78.16 ± 5.64°C at a DC of 100%, 70.17 ± 6.43°C at 10%, 53.17 ± 4.54°C at 5%, and 42.00 ± 5.55°C at 2%, respectively. Inertial cavitation was much stronger in the pulsed-HIFU than that in the continuous-wave HIFU exposure. Compared to 100%-DC exposure, the mean volume of lesion induced by 5 s exposure at 10%-DC was significantly larger, but smaller at 2%-DC. Conclusions. MSNC-PFH nanoemulsion can significantly enhance HIFU ablation. Appropriate pulsed-HIFU exposure could significantly increase the volume of lesion and reduce total US energy required for HIFU ablation. Hindawi Publishing Corporation 2016 2016-06-23 /pmc/articles/PMC4935909/ /pubmed/27419138 http://dx.doi.org/10.1155/2016/7936902 Text en Copyright © 2016 Lu-Yan Zhao et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Zhao, Lu-Yan Zou, Jian-Zhong Chen, Zong-Gui Liu, Shan Jiao, Jiao Wu, Feng Acoustic Cavitation Enhances Focused Ultrasound Ablation with Phase-Shift Inorganic Perfluorohexane Nanoemulsions: An In Vitro Study Using a Clinical Device |
title | Acoustic Cavitation Enhances Focused Ultrasound Ablation with Phase-Shift Inorganic Perfluorohexane Nanoemulsions: An In Vitro Study Using a Clinical Device |
title_full | Acoustic Cavitation Enhances Focused Ultrasound Ablation with Phase-Shift Inorganic Perfluorohexane Nanoemulsions: An In Vitro Study Using a Clinical Device |
title_fullStr | Acoustic Cavitation Enhances Focused Ultrasound Ablation with Phase-Shift Inorganic Perfluorohexane Nanoemulsions: An In Vitro Study Using a Clinical Device |
title_full_unstemmed | Acoustic Cavitation Enhances Focused Ultrasound Ablation with Phase-Shift Inorganic Perfluorohexane Nanoemulsions: An In Vitro Study Using a Clinical Device |
title_short | Acoustic Cavitation Enhances Focused Ultrasound Ablation with Phase-Shift Inorganic Perfluorohexane Nanoemulsions: An In Vitro Study Using a Clinical Device |
title_sort | acoustic cavitation enhances focused ultrasound ablation with phase-shift inorganic perfluorohexane nanoemulsions: an in vitro study using a clinical device |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4935909/ https://www.ncbi.nlm.nih.gov/pubmed/27419138 http://dx.doi.org/10.1155/2016/7936902 |
work_keys_str_mv | AT zhaoluyan acousticcavitationenhancesfocusedultrasoundablationwithphaseshiftinorganicperfluorohexanenanoemulsionsaninvitrostudyusingaclinicaldevice AT zoujianzhong acousticcavitationenhancesfocusedultrasoundablationwithphaseshiftinorganicperfluorohexanenanoemulsionsaninvitrostudyusingaclinicaldevice AT chenzonggui acousticcavitationenhancesfocusedultrasoundablationwithphaseshiftinorganicperfluorohexanenanoemulsionsaninvitrostudyusingaclinicaldevice AT liushan acousticcavitationenhancesfocusedultrasoundablationwithphaseshiftinorganicperfluorohexanenanoemulsionsaninvitrostudyusingaclinicaldevice AT jiaojiao acousticcavitationenhancesfocusedultrasoundablationwithphaseshiftinorganicperfluorohexanenanoemulsionsaninvitrostudyusingaclinicaldevice AT wufeng acousticcavitationenhancesfocusedultrasoundablationwithphaseshiftinorganicperfluorohexanenanoemulsionsaninvitrostudyusingaclinicaldevice |