Cargando…
Diffusion-Weighted MRI of Malignant versus Benign Portal Vein Thrombosis
OBJECTIVE: To validate the diffusion-weighted MRI (DWI) for differentiation of benign from malignant portal vein thrombosis. MATERIALS AND METHODS: The Institutional Review Board approved this retrospective study and waived informed consent. A total of 59 consecutive patients (52 men and 7 women, ag...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4936175/ https://www.ncbi.nlm.nih.gov/pubmed/27390544 http://dx.doi.org/10.3348/kjr.2016.17.4.533 |
_version_ | 1782441521641947136 |
---|---|
author | Ahn, Jhii-Hyun Yu, Jeong-Sik Cho, Eun-Suk Chung, Jae-Joon Kim, Joo Hee Kim, Ki Whang |
author_facet | Ahn, Jhii-Hyun Yu, Jeong-Sik Cho, Eun-Suk Chung, Jae-Joon Kim, Joo Hee Kim, Ki Whang |
author_sort | Ahn, Jhii-Hyun |
collection | PubMed |
description | OBJECTIVE: To validate the diffusion-weighted MRI (DWI) for differentiation of benign from malignant portal vein thrombosis. MATERIALS AND METHODS: The Institutional Review Board approved this retrospective study and waived informed consent. A total of 59 consecutive patients (52 men and 7 women, aged 40–85 years) with grossly defined portal vein thrombus (PVT) on hepatic MRI were retrospectively analyzed. Among them, liver cirrhosis was found in 45 patients, and hepatocellular carcinoma in 47 patients. DWI was performed using b values of 50 and 800 sec/mm(2) at 1.5-T unit. A thrombus was considered malignant if it enhanced on dynamic CT or MRI; otherwise, it was considered bland. There were 18 bland thrombi and 49 malignant thrombi in 59 patients, including 8 patients with simultaneous benign and malignant PVT. Mean apparent diffusion coefficients (ADCs) of benign and malignant PVTs were compared by using Mann-Whitney U test. Diagnostic accuracy was evaluated using receiver operating characteristic (ROC) curve analysis. RESULTS: The mean ADC ± standard deviation of bland and malignant PVT were 1.00 ± 0.39 × 10(-3) mm(2)/sec and 0.92 ± 0.25 × 10(-3) mm(2)/sec, respectively; without significant difference (p = 0.799). The area under ROC curve for ADC was 0.520. An ADC value of > 1.35 × 10(-3) mm(2)/sec predicted bland PVT with a specificity of 94.6% (95% confidence interval [CI]: 84.9–98.9%) and a sensitivity of 22.2% (95% CI: 6.4–47.6%), respectively. CONCLUSION: Due to the wide range and considerable overlap of the ADCs, DWI cannot differentiate the benign from malignant thrombi efficiently. |
format | Online Article Text |
id | pubmed-4936175 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-49361752016-07-07 Diffusion-Weighted MRI of Malignant versus Benign Portal Vein Thrombosis Ahn, Jhii-Hyun Yu, Jeong-Sik Cho, Eun-Suk Chung, Jae-Joon Kim, Joo Hee Kim, Ki Whang Korean J Radiol Gastrointestinal Imaging OBJECTIVE: To validate the diffusion-weighted MRI (DWI) for differentiation of benign from malignant portal vein thrombosis. MATERIALS AND METHODS: The Institutional Review Board approved this retrospective study and waived informed consent. A total of 59 consecutive patients (52 men and 7 women, aged 40–85 years) with grossly defined portal vein thrombus (PVT) on hepatic MRI were retrospectively analyzed. Among them, liver cirrhosis was found in 45 patients, and hepatocellular carcinoma in 47 patients. DWI was performed using b values of 50 and 800 sec/mm(2) at 1.5-T unit. A thrombus was considered malignant if it enhanced on dynamic CT or MRI; otherwise, it was considered bland. There were 18 bland thrombi and 49 malignant thrombi in 59 patients, including 8 patients with simultaneous benign and malignant PVT. Mean apparent diffusion coefficients (ADCs) of benign and malignant PVTs were compared by using Mann-Whitney U test. Diagnostic accuracy was evaluated using receiver operating characteristic (ROC) curve analysis. RESULTS: The mean ADC ± standard deviation of bland and malignant PVT were 1.00 ± 0.39 × 10(-3) mm(2)/sec and 0.92 ± 0.25 × 10(-3) mm(2)/sec, respectively; without significant difference (p = 0.799). The area under ROC curve for ADC was 0.520. An ADC value of > 1.35 × 10(-3) mm(2)/sec predicted bland PVT with a specificity of 94.6% (95% confidence interval [CI]: 84.9–98.9%) and a sensitivity of 22.2% (95% CI: 6.4–47.6%), respectively. CONCLUSION: Due to the wide range and considerable overlap of the ADCs, DWI cannot differentiate the benign from malignant thrombi efficiently. The Korean Society of Radiology 2016 2016-06-27 /pmc/articles/PMC4936175/ /pubmed/27390544 http://dx.doi.org/10.3348/kjr.2016.17.4.533 Text en Copyright © 2016 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Gastrointestinal Imaging Ahn, Jhii-Hyun Yu, Jeong-Sik Cho, Eun-Suk Chung, Jae-Joon Kim, Joo Hee Kim, Ki Whang Diffusion-Weighted MRI of Malignant versus Benign Portal Vein Thrombosis |
title | Diffusion-Weighted MRI of Malignant versus Benign Portal Vein Thrombosis |
title_full | Diffusion-Weighted MRI of Malignant versus Benign Portal Vein Thrombosis |
title_fullStr | Diffusion-Weighted MRI of Malignant versus Benign Portal Vein Thrombosis |
title_full_unstemmed | Diffusion-Weighted MRI of Malignant versus Benign Portal Vein Thrombosis |
title_short | Diffusion-Weighted MRI of Malignant versus Benign Portal Vein Thrombosis |
title_sort | diffusion-weighted mri of malignant versus benign portal vein thrombosis |
topic | Gastrointestinal Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4936175/ https://www.ncbi.nlm.nih.gov/pubmed/27390544 http://dx.doi.org/10.3348/kjr.2016.17.4.533 |
work_keys_str_mv | AT ahnjhiihyun diffusionweightedmriofmalignantversusbenignportalveinthrombosis AT yujeongsik diffusionweightedmriofmalignantversusbenignportalveinthrombosis AT choeunsuk diffusionweightedmriofmalignantversusbenignportalveinthrombosis AT chungjaejoon diffusionweightedmriofmalignantversusbenignportalveinthrombosis AT kimjoohee diffusionweightedmriofmalignantversusbenignportalveinthrombosis AT kimkiwhang diffusionweightedmriofmalignantversusbenignportalveinthrombosis |