Cargando…

Intra-patient comparison of parietal pleural biopsies by rigid forceps, flexible forceps and cryoprobe obtained during medical thoracoscopy: a prospective series of 80 cases with pleural effusion

BACKGROUND: There is only few data available on the use of cryotechnique during medical thoracoscopy. METHODS: Medical thoracoscopy was performed in consecutive patients with pleural effusion. Prospectively, biopsies were taken by rigid forceps, flexible forceps and cryoprobe. Specimen size, depth a...

Descripción completa

Detalles Bibliográficos
Autores principales: Wurps, H., Schönfeld, N., Bauer, T. T., Bock, M., Duve, C., Sauer, R., Mairinger, T., Griff, S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4937596/
https://www.ncbi.nlm.nih.gov/pubmed/27387441
http://dx.doi.org/10.1186/s12890-016-0258-5
Descripción
Sumario:BACKGROUND: There is only few data available on the use of cryotechnique during medical thoracoscopy. METHODS: Medical thoracoscopy was performed in consecutive patients with pleural effusion. Prospectively, biopsies were taken by rigid forceps, flexible forceps and cryoprobe. Specimen size, depth and diagnostic yield were compared. RESULTS: 80 Patients were included. 408 biopsies were taken (205 rigid biopsies, 104 flexible biopsies, 99 cryobiopsies). Mean surface area of rigid biopsies was 22.6 ± 20.4 mm(2) (flexible biopsies: 7.1 ± 9.3 mm(2), cryobiopsies: 14.4 ± 12.8 mm(2)). Rigid biopsies were significantly larger than cryobiopsies (p < 0.001) and flexible biopsies (p < 0.001), crybiopsies were significantly larger than flexible biopsies (p < 0.01). A deep biopsy containing fatty tissue was harvested in 63 % of rigid biopsies (cryobiopsy: 49.5 % flexible biopsy: 39.5 %). In 79/80 cases (98.7 % 95 % CI cannot be calculated) a diagnosis was obtained by rigid biopsy (cryobiopsy: 73/80 cases (91.3 % 95 % CI 86.0 – 96.5 %), flexible biopsy: 74/80 cases (92.5 % 95 % CI 88.6 – 97.4 %)). Diagnostic yield achieved with cryobiopsies was inferior to the yield of rigid biopsies (Difference: 12.7 %), but non-inferior to flexible biopsies (Difference: 6.5 %). CONCLUSION: Cryobiopsies in medical thoracoscopy are safe with high diagnostic yield, non-inferior to flexible biopsies with increased tissue quantity and quality. Cryotechnique can develop an important role in medical thoracoscopy in the near future when rigid thoracoscopy is not available.