Cargando…
Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT
OBJECTIVE(S): IQ-SPECT is an advanced high-speed SPECT modality for myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQ-SPECT with conventional SPECT in terms of performance, based on standa...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Asia Oceania Journal of Nuclear Medicine & Biology
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4937695/ https://www.ncbi.nlm.nih.gov/pubmed/27408867 |
_version_ | 1782441756489416704 |
---|---|
author | Matsutomo, Norikazu Nagaki, Akio Sasaki, Masayuki |
author_facet | Matsutomo, Norikazu Nagaki, Akio Sasaki, Masayuki |
author_sort | Matsutomo, Norikazu |
collection | PubMed |
description | OBJECTIVE(S): IQ-SPECT is an advanced high-speed SPECT modality for myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQ-SPECT with conventional SPECT in terms of performance, based on standard clinical protocols. In addition, we examined the concordance between conventional and IQ_SPECT in patients with coronary artery disease (CAD). METHODS: Fifty-three patients, undergoing rest-gated MPI for the evaluation of known or suspected CAD, were enrolled in this study. In each patient, conventional SPECT ((99m)Tc-tetrofosmin, 9.6 min and (201)Tl, 12.9 min) was performed, immediately followed by IQ-SPECT, using a short acquisition time (4.3 min for (99m)Tc-tetrofosmin and 6.2 min for (201)Tl). A quantitative analysis was performed on an MPI polar map, using a 20-segment model of the left ventricle. An automated analysis by gated SPECT was carried out to determine the left ventricular volume and function including end-diastolic volume (EDV), end-systolic volume (ESV), and left ventricular ejection fraction (LVEF). The degree of concordance between conventional SPECT and IQ-SPECT images was evaluated according to linear regression and Bland-Altman analyses. RESULTS: The segmental percent uptake exhibited a significant correlation between IQ-SPECT and conventional SPECT (P<0.05). The mean differences in (99m)Tc-tetrofosmin studies were 1.1±6.6% (apex), 2.8±5.7% (anterior wall), 2.9±6.2% (septal wall), 4.9±6.7% (lateral wall), and 1.8±5.6% (inferior wall). Meanwhile, regarding the (201)Tl-SPECT studies, these values were 1.6±6.9%, 2.0±6.6%, 2.1±5.9%, 3.3±7.2%, and 2.4±5.8%, respectively. Although the mean LVEF in IQ-SPECT tended to be higher than that observed in conventional SPECT (conventional SPECT=64.8±11.8% and IQ-SPECT=68.3±12.1% for (99m)Tc-tetrofosmin; conventional SPECT= 56.0±11.7% and IQ-SPECT=61.5±12.2% for (201)Tl), quantitative parameters were not significantly different between IQ-SPECT and conventional SPECT. CONCLUSION: According to the (99m)Tc-tetrofosmin and (201)Tl protocols, IQ-SPECT images were comparable to and in agreement with conventional SPECT images. Our results suggest that IQ-SPECT is a useful technology for MPI SPECT, and can lead to an increase in scan efficiency and patient comfort. |
format | Online Article Text |
id | pubmed-4937695 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Asia Oceania Journal of Nuclear Medicine & Biology |
record_format | MEDLINE/PubMed |
spelling | pubmed-49376952016-07-12 Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT Matsutomo, Norikazu Nagaki, Akio Sasaki, Masayuki Asia Ocean J Nucl Med Biol Original Article OBJECTIVE(S): IQ-SPECT is an advanced high-speed SPECT modality for myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQ-SPECT with conventional SPECT in terms of performance, based on standard clinical protocols. In addition, we examined the concordance between conventional and IQ_SPECT in patients with coronary artery disease (CAD). METHODS: Fifty-three patients, undergoing rest-gated MPI for the evaluation of known or suspected CAD, were enrolled in this study. In each patient, conventional SPECT ((99m)Tc-tetrofosmin, 9.6 min and (201)Tl, 12.9 min) was performed, immediately followed by IQ-SPECT, using a short acquisition time (4.3 min for (99m)Tc-tetrofosmin and 6.2 min for (201)Tl). A quantitative analysis was performed on an MPI polar map, using a 20-segment model of the left ventricle. An automated analysis by gated SPECT was carried out to determine the left ventricular volume and function including end-diastolic volume (EDV), end-systolic volume (ESV), and left ventricular ejection fraction (LVEF). The degree of concordance between conventional SPECT and IQ-SPECT images was evaluated according to linear regression and Bland-Altman analyses. RESULTS: The segmental percent uptake exhibited a significant correlation between IQ-SPECT and conventional SPECT (P<0.05). The mean differences in (99m)Tc-tetrofosmin studies were 1.1±6.6% (apex), 2.8±5.7% (anterior wall), 2.9±6.2% (septal wall), 4.9±6.7% (lateral wall), and 1.8±5.6% (inferior wall). Meanwhile, regarding the (201)Tl-SPECT studies, these values were 1.6±6.9%, 2.0±6.6%, 2.1±5.9%, 3.3±7.2%, and 2.4±5.8%, respectively. Although the mean LVEF in IQ-SPECT tended to be higher than that observed in conventional SPECT (conventional SPECT=64.8±11.8% and IQ-SPECT=68.3±12.1% for (99m)Tc-tetrofosmin; conventional SPECT= 56.0±11.7% and IQ-SPECT=61.5±12.2% for (201)Tl), quantitative parameters were not significantly different between IQ-SPECT and conventional SPECT. CONCLUSION: According to the (99m)Tc-tetrofosmin and (201)Tl protocols, IQ-SPECT images were comparable to and in agreement with conventional SPECT images. Our results suggest that IQ-SPECT is a useful technology for MPI SPECT, and can lead to an increase in scan efficiency and patient comfort. Asia Oceania Journal of Nuclear Medicine & Biology 2014 /pmc/articles/PMC4937695/ /pubmed/27408867 Text en Copyright: © mums.ac.ir http://creativecommons.org/licenses/by/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Matsutomo, Norikazu Nagaki, Akio Sasaki, Masayuki Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT |
title | Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT |
title_full | Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT |
title_fullStr | Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT |
title_full_unstemmed | Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT |
title_short | Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT |
title_sort | performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional spect |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4937695/ https://www.ncbi.nlm.nih.gov/pubmed/27408867 |
work_keys_str_mv | AT matsutomonorikazu performanceofmyocardialperfusionimagingusingmultifocusfanbeamcollimatorwithresolutionrecoveryreconstructioninacomparisonwithconventionalspect AT nagakiakio performanceofmyocardialperfusionimagingusingmultifocusfanbeamcollimatorwithresolutionrecoveryreconstructioninacomparisonwithconventionalspect AT sasakimasayuki performanceofmyocardialperfusionimagingusingmultifocusfanbeamcollimatorwithresolutionrecoveryreconstructioninacomparisonwithconventionalspect |