Double-low protocol for hepatic dynamic CT scan: Effect of low tube voltage and low-dose iodine contrast agent on image quality

The radiation-induced carcinogenesis from computed tomography (CT) and iodine contrast agent induced nephropathy has attracted international attention. The reduction of the radiation dose and iodine intake in CT scan is always a direction for researchers to strive. The purpose of this study was to e...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Xiuli, Li, Shaodong, Liu, Wenlou, Huang, Ning, Li, Jingjing, Cheng, Li, Xu, Kai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4937926/
https://www.ncbi.nlm.nih.gov/pubmed/27368012
http://dx.doi.org/10.1097/MD.0000000000004004
_version_ 1782441793852276736
author Zhang, Xiuli
Li, Shaodong
Liu, Wenlou
Huang, Ning
Li, Jingjing
Cheng, Li
Xu, Kai
author_facet Zhang, Xiuli
Li, Shaodong
Liu, Wenlou
Huang, Ning
Li, Jingjing
Cheng, Li
Xu, Kai
author_sort Zhang, Xiuli
collection PubMed
description The radiation-induced carcinogenesis from computed tomography (CT) and iodine contrast agent induced nephropathy has attracted international attention. The reduction of the radiation dose and iodine intake in CT scan is always a direction for researchers to strive. The purpose of this study was to evaluate the feasibility of a “double-low” (i.e., low tube voltage and low-dose iodine contrast agent) scanning protocol for dynamic hepatic CT with the adaptive statistical iterative reconstruction (ASIR) in patients with a body mass index (BMI) of 18.5 to 27.9 kg/m(2). A total of 128 consecutive patients with a BMI between 18.5 and 27.9 kg/m(2) were randomly assigned into 3 groups according to tube voltage, iodine contrast agent, and reconstruction algorithms. Group A (the “double-low” protocol): 100 kVp tube voltage with 40% ASIR, iodixanol at 270 mg I/mL, group B: 120 kVp tube voltage with filtered back projection (FBP), iodixanol at 270 mg I/ mL, and group C: 120 kVp tube voltage with FBP, ioversol at 350 mg I/ mL. The volume CT dose index (CTDI(vol)) and effective dose (ED) in group A were lower than those in group B and C (all P < 0.01). The iodine intake in group A was decreased by approximately 26.5% than group C, whereas no statistical difference was observed between group A and B (P > 0.05). There was no significant difference of the CT values between group A and C (P > 0.05), which both showed higher CT values than that in group B (P < 0.001). However, no statistic difference was observed in the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and image-quality scores among the 3 groups (all P > 0.05). Near-perfect consistency of the evaluation for group A, B, and C (Kenall's W = 0.921, 0.874, and 0.949, respectively) was obtained by the 4 readers with respect to the overall image quality. These results suggested that the “double-low” protocol with ASIR algorithm for multi-phase hepatic CT scan can dramatically decrease radiation dose and iodine intake with adequate image quality in patients with BMI of 18.5 to 27.9 kg/m(2).
format Online
Article
Text
id pubmed-4937926
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-49379262016-08-18 Double-low protocol for hepatic dynamic CT scan: Effect of low tube voltage and low-dose iodine contrast agent on image quality Zhang, Xiuli Li, Shaodong Liu, Wenlou Huang, Ning Li, Jingjing Cheng, Li Xu, Kai Medicine (Baltimore) 6800 The radiation-induced carcinogenesis from computed tomography (CT) and iodine contrast agent induced nephropathy has attracted international attention. The reduction of the radiation dose and iodine intake in CT scan is always a direction for researchers to strive. The purpose of this study was to evaluate the feasibility of a “double-low” (i.e., low tube voltage and low-dose iodine contrast agent) scanning protocol for dynamic hepatic CT with the adaptive statistical iterative reconstruction (ASIR) in patients with a body mass index (BMI) of 18.5 to 27.9 kg/m(2). A total of 128 consecutive patients with a BMI between 18.5 and 27.9 kg/m(2) were randomly assigned into 3 groups according to tube voltage, iodine contrast agent, and reconstruction algorithms. Group A (the “double-low” protocol): 100 kVp tube voltage with 40% ASIR, iodixanol at 270 mg I/mL, group B: 120 kVp tube voltage with filtered back projection (FBP), iodixanol at 270 mg I/ mL, and group C: 120 kVp tube voltage with FBP, ioversol at 350 mg I/ mL. The volume CT dose index (CTDI(vol)) and effective dose (ED) in group A were lower than those in group B and C (all P < 0.01). The iodine intake in group A was decreased by approximately 26.5% than group C, whereas no statistical difference was observed between group A and B (P > 0.05). There was no significant difference of the CT values between group A and C (P > 0.05), which both showed higher CT values than that in group B (P < 0.001). However, no statistic difference was observed in the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and image-quality scores among the 3 groups (all P > 0.05). Near-perfect consistency of the evaluation for group A, B, and C (Kenall's W = 0.921, 0.874, and 0.949, respectively) was obtained by the 4 readers with respect to the overall image quality. These results suggested that the “double-low” protocol with ASIR algorithm for multi-phase hepatic CT scan can dramatically decrease radiation dose and iodine intake with adequate image quality in patients with BMI of 18.5 to 27.9 kg/m(2). Wolters Kluwer Health 2016-07-01 /pmc/articles/PMC4937926/ /pubmed/27368012 http://dx.doi.org/10.1097/MD.0000000000004004 Text en Copyright © 2016 Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NoDerivatives License 4.0, which allows for redistribution, commercial and non-commercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0
spellingShingle 6800
Zhang, Xiuli
Li, Shaodong
Liu, Wenlou
Huang, Ning
Li, Jingjing
Cheng, Li
Xu, Kai
Double-low protocol for hepatic dynamic CT scan: Effect of low tube voltage and low-dose iodine contrast agent on image quality
title Double-low protocol for hepatic dynamic CT scan: Effect of low tube voltage and low-dose iodine contrast agent on image quality
title_full Double-low protocol for hepatic dynamic CT scan: Effect of low tube voltage and low-dose iodine contrast agent on image quality
title_fullStr Double-low protocol for hepatic dynamic CT scan: Effect of low tube voltage and low-dose iodine contrast agent on image quality
title_full_unstemmed Double-low protocol for hepatic dynamic CT scan: Effect of low tube voltage and low-dose iodine contrast agent on image quality
title_short Double-low protocol for hepatic dynamic CT scan: Effect of low tube voltage and low-dose iodine contrast agent on image quality
title_sort double-low protocol for hepatic dynamic ct scan: effect of low tube voltage and low-dose iodine contrast agent on image quality
topic 6800
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4937926/
https://www.ncbi.nlm.nih.gov/pubmed/27368012
http://dx.doi.org/10.1097/MD.0000000000004004
work_keys_str_mv AT zhangxiuli doublelowprotocolforhepaticdynamicctscaneffectoflowtubevoltageandlowdoseiodinecontrastagentonimagequality
AT lishaodong doublelowprotocolforhepaticdynamicctscaneffectoflowtubevoltageandlowdoseiodinecontrastagentonimagequality
AT liuwenlou doublelowprotocolforhepaticdynamicctscaneffectoflowtubevoltageandlowdoseiodinecontrastagentonimagequality
AT huangning doublelowprotocolforhepaticdynamicctscaneffectoflowtubevoltageandlowdoseiodinecontrastagentonimagequality
AT lijingjing doublelowprotocolforhepaticdynamicctscaneffectoflowtubevoltageandlowdoseiodinecontrastagentonimagequality
AT chengli doublelowprotocolforhepaticdynamicctscaneffectoflowtubevoltageandlowdoseiodinecontrastagentonimagequality
AT xukai doublelowprotocolforhepaticdynamicctscaneffectoflowtubevoltageandlowdoseiodinecontrastagentonimagequality