Cargando…

Evaluation of a Hybrid Dynamic Stabilization and Fusion System in the Lumbar Spine: A 10 Year Experience

Introduction: The development of adjacent-segment disease is a recognized consequence of lumbar fusion surgery. Posterior dynamic stabilization, or motion preservation, techniques have been developed which theoretically decrease stress on adjacent segments following fusion. This study presents the e...

Descripción completa

Detalles Bibliográficos
Autores principales: Kashkoush, Ahmed, Agarwal, Nitin, Paschel, Erin, Goldschmidt, Ezequiel, Gerszten, Peter C
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4938630/
https://www.ncbi.nlm.nih.gov/pubmed/27433416
http://dx.doi.org/10.7759/cureus.637
_version_ 1782441894900400128
author Kashkoush, Ahmed
Agarwal, Nitin
Paschel, Erin
Goldschmidt, Ezequiel
Gerszten, Peter C
author_facet Kashkoush, Ahmed
Agarwal, Nitin
Paschel, Erin
Goldschmidt, Ezequiel
Gerszten, Peter C
author_sort Kashkoush, Ahmed
collection PubMed
description Introduction: The development of adjacent-segment disease is a recognized consequence of lumbar fusion surgery. Posterior dynamic stabilization, or motion preservation, techniques have been developed which theoretically decrease stress on adjacent segments following fusion. This study presents the experience of using a hybrid dynamic stabilization and fusion construct for degenerative lumbar spine pathology in place of rigid arthrodesis. Methods: A clinical cohort investigation was conducted of 66 consecutive patients (31 female, 35 male; mean age: 53 years, range: 25 – 76 years) who underwent posterior lumbar instrumentation with the Dynesys Transition Optima (DTO) implant (Zimmer-Biomet Spine, Warsaw, IN) hybrid dynamic stabilization and fusion system over a 10-year period. The median length of follow-up was five years. DTO consists of pedicle screw fixation coupled to a rigid rod as well as a flexible longitudinal connecting system. All patients had symptoms of back pain and neurogenic claudication refractory to non-surgical treatment. Patients underwent lumbar arthrodesis surgery in which the hybrid system was used for stabilization instead of arthrodesis of the stenotic adjacent level. Results: Indications for DTO instrumentation were primary degenerative disc disease (n = 52) and failed back surgery syndrome (n = 14). The most common dynamically stabilized and fused segments were L3-L4 (n = 37) and L5-S1 (n = 33), respectively. Thirty-eight patients (56%) underwent decompression at the dynamically stabilized level, and 57 patients (86%) had an interbody device placed at the level of arthrodesis. Complications during the follow-up period included a single case of screw breakage and a single case of pseudoarthrosis. Ten patients (15%) subsequently underwent conversion of the dynamic stabilization portion of their DTO instrumentation to rigid spinal arthrodesis. Conclusion: The DTO system represents a novel hybrid dynamic stabilization and fusion construct. This 10-year experience found the device to be highly effective as well as safe. The technique may serve as an alternative to multilevel arthrodesis. Implantation of a motion-preserving dynamic stabilization device immediately adjacent to a fused level instead of extending a rigid construct may reduce the subsequent development of adjacent-segment disease in this patient population.
format Online
Article
Text
id pubmed-4938630
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-49386302016-07-18 Evaluation of a Hybrid Dynamic Stabilization and Fusion System in the Lumbar Spine: A 10 Year Experience Kashkoush, Ahmed Agarwal, Nitin Paschel, Erin Goldschmidt, Ezequiel Gerszten, Peter C Cureus Neurosurgery Introduction: The development of adjacent-segment disease is a recognized consequence of lumbar fusion surgery. Posterior dynamic stabilization, or motion preservation, techniques have been developed which theoretically decrease stress on adjacent segments following fusion. This study presents the experience of using a hybrid dynamic stabilization and fusion construct for degenerative lumbar spine pathology in place of rigid arthrodesis. Methods: A clinical cohort investigation was conducted of 66 consecutive patients (31 female, 35 male; mean age: 53 years, range: 25 – 76 years) who underwent posterior lumbar instrumentation with the Dynesys Transition Optima (DTO) implant (Zimmer-Biomet Spine, Warsaw, IN) hybrid dynamic stabilization and fusion system over a 10-year period. The median length of follow-up was five years. DTO consists of pedicle screw fixation coupled to a rigid rod as well as a flexible longitudinal connecting system. All patients had symptoms of back pain and neurogenic claudication refractory to non-surgical treatment. Patients underwent lumbar arthrodesis surgery in which the hybrid system was used for stabilization instead of arthrodesis of the stenotic adjacent level. Results: Indications for DTO instrumentation were primary degenerative disc disease (n = 52) and failed back surgery syndrome (n = 14). The most common dynamically stabilized and fused segments were L3-L4 (n = 37) and L5-S1 (n = 33), respectively. Thirty-eight patients (56%) underwent decompression at the dynamically stabilized level, and 57 patients (86%) had an interbody device placed at the level of arthrodesis. Complications during the follow-up period included a single case of screw breakage and a single case of pseudoarthrosis. Ten patients (15%) subsequently underwent conversion of the dynamic stabilization portion of their DTO instrumentation to rigid spinal arthrodesis. Conclusion: The DTO system represents a novel hybrid dynamic stabilization and fusion construct. This 10-year experience found the device to be highly effective as well as safe. The technique may serve as an alternative to multilevel arthrodesis. Implantation of a motion-preserving dynamic stabilization device immediately adjacent to a fused level instead of extending a rigid construct may reduce the subsequent development of adjacent-segment disease in this patient population. Cureus 2016-06-10 /pmc/articles/PMC4938630/ /pubmed/27433416 http://dx.doi.org/10.7759/cureus.637 Text en Copyright © 2016, Kashkoush et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Neurosurgery
Kashkoush, Ahmed
Agarwal, Nitin
Paschel, Erin
Goldschmidt, Ezequiel
Gerszten, Peter C
Evaluation of a Hybrid Dynamic Stabilization and Fusion System in the Lumbar Spine: A 10 Year Experience
title Evaluation of a Hybrid Dynamic Stabilization and Fusion System in the Lumbar Spine: A 10 Year Experience
title_full Evaluation of a Hybrid Dynamic Stabilization and Fusion System in the Lumbar Spine: A 10 Year Experience
title_fullStr Evaluation of a Hybrid Dynamic Stabilization and Fusion System in the Lumbar Spine: A 10 Year Experience
title_full_unstemmed Evaluation of a Hybrid Dynamic Stabilization and Fusion System in the Lumbar Spine: A 10 Year Experience
title_short Evaluation of a Hybrid Dynamic Stabilization and Fusion System in the Lumbar Spine: A 10 Year Experience
title_sort evaluation of a hybrid dynamic stabilization and fusion system in the lumbar spine: a 10 year experience
topic Neurosurgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4938630/
https://www.ncbi.nlm.nih.gov/pubmed/27433416
http://dx.doi.org/10.7759/cureus.637
work_keys_str_mv AT kashkoushahmed evaluationofahybriddynamicstabilizationandfusionsysteminthelumbarspinea10yearexperience
AT agarwalnitin evaluationofahybriddynamicstabilizationandfusionsysteminthelumbarspinea10yearexperience
AT paschelerin evaluationofahybriddynamicstabilizationandfusionsysteminthelumbarspinea10yearexperience
AT goldschmidtezequiel evaluationofahybriddynamicstabilizationandfusionsysteminthelumbarspinea10yearexperience
AT gersztenpeterc evaluationofahybriddynamicstabilizationandfusionsysteminthelumbarspinea10yearexperience